Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW — CEC Solar Module Specifications

Manufacturer: Hanwha Qcells (Qidong) Co Ltd Registry: CEC Verified Engineering Specification

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW is a 295.0 W STC (265.1 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.08% efficiency, 45.1 V Voc at 25 C, and 50.14 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
265.1 W
Voc @ 25C
45.1 V
Efficiency
15.08%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW Compare Against Peer CEC Listings?

Solar engineering breakdown for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Hanwha Qcells (Qidong) Co Ltd and peers, Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW stands 16.2 W above the 278.8 W Multi-c-Si median and typical 89.9% PTC-to-STC thermal output (265.1 W real-world rating). Sizing 6 kW (21 panels) to 10 kW (34 panels) yields $1,552-$2,510/yr in baseline US bill offset. Mid-range 45.1 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW Fall Across Listed CEC Models?

Distribution marker showing Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW (295.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanwha Qcells (Qid: 295.0 W

What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW?

Dataset percentiles tracking Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW Engineering BenchmarksPercentile comparison of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention89.9%Module Efficiency15.08%

What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW?

Benchmark highlights for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,624

15.08% Aperture Efficiency

Power density 150.8 W/m2 (4.83 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.14 V at -10 C (551.5 V string) and 51.57 V at -20 C (11 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 54.8 m2 (590 sq ft) producing 7,423 W PTC; NEC 690.8 OCPD floor is 13.14 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.1 * (1 + (-0.319/100) * (-10 - 25)) = 50.14 V | OCPD = 1.56 * 8.42 = 13.14 A

Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW: Voc=45.1 V, beta_Voc=-0.319%/C, Isc=8.42 A, STC=295.0 W, Area=1.956 m2.

Result: 11 panels max on 600 V (551.5 V); 28 panels for 8 kW (590 sq ft).

What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW?

Official CEC datasheet figures for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 265.1 W (89.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.42 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.4 V / 8.11 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.319 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.08% (1.956 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 442 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 590 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 716 sq ft $2,510 $4,245

How Many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW (50.14 V at 14 F).

Computed from Voc=45.1V and beta_Voc=-0.319%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.57 V 11 panels 567.3 V 19 panels
-10 C (14 F) 50.14 V 11 panels 551.5 V 19 panels
0 C (32 F) 48.7 V 12 panels 584.4 V 20 panels
25 C (77 F STC) 45.1 V 13 panels 586.3 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW?

Competing CEC solar panels closest to Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW in nameplate wattage and Voc, starting with Centrosolar America TP7 295xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TP7 295xx
Centrosolar America
295.0 W Tie (0 W) 45.1 V 15.13% 90.4%
Centrosolar America TP7S 295xx
Centrosolar America
295.0 W Tie (0 W) 45.1 V 15.13% 90.4%
BYD Company Limited BYD295P6K-36
BYD Company Limited
295.0 W Tie (0 W) 44.9 V 15.21% 91.5%
Chinaland Solar Energy HSE295-72M
Chinaland Solar Energy
295.0 W Tie (0 W) 44.4 V 15.28% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW?

Evaluate Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW (295.0 W STC, 45.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW reaches 51.57 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 590 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (590 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW 8 kW Residential Fit

Needs 28 modules (590 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America TP7 295xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 265.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW?

Multiplying Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW's 8.42 A short-circuit current by 1.56 equals 13.14 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.14 V cold Voc at 14 F and handles 8.42 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW at 11 panels on 600 V.

Is Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.