Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q — CEC Solar Module Specifications

Manufacturer: Hanwha Qcells (Qidong) Co Ltd Registry: CEC Verified Engineering Specification

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q is a 305.0 W STC (274.2 W PTC) Multi-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 15.78% efficiency, 45.5 V Voc at 25 C, and 50.63 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
305.0 W
PTC Wattage
274.2 W
Voc @ 25C
45.5 V
Efficiency
15.78%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q Compare Against Peer CEC Listings?

Solar engineering breakdown for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Hanwha Qcells (Qidong) Co Ltd and peers, Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q stands 26.2 W above the 278.8 W Multi-c-Si median and typical 89.9% PTC-to-STC thermal output (274.2 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,527-$2,518/yr in baseline US bill offset. Mid-range 45.5 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q Fall Across Listed CEC Models?

Distribution marker showing Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q (305.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q (305.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanwha Qcells (Qid: 305.0 W

What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q?

Dataset percentiles tracking Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q Engineering BenchmarksPercentile comparison of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage305.0 WPTC/STC Retention89.9%Module Efficiency15.78%

What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q?

Benchmark highlights for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #16,131 / 21,677

305.0 W STC · Higher Than 23.9%

305.0 W STC (-80.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,455

15.78% Aperture Efficiency

Power density 157.8 W/m2 (4.13 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.63 V at -10 C (556.9 V string) and 52.09 V at -20 C (11 max).

8 kW Reference Array

27 Panels = 8,235 W STC

Occupies 52.2 m2 (562 sq ft) producing 7,403 W PTC; NEC 690.8 OCPD floor is 13.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.5 * (1 + (-0.322/100) * (-10 - 25)) = 50.63 V | OCPD = 1.56 * 8.9 = 13.88 A

Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q: Voc=45.5 V, beta_Voc=-0.322%/C, Isc=8.9 A, STC=305.0 W, Area=1.933 m2.

Result: 11 panels max on 600 V (556.9 V); 27 panels for 8 kW (562 sq ft).

What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q?

Official CEC datasheet figures for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 305.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 274.2 W (89.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.1 V / 8.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.322 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.78% (1.933 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.1 kW 416 sq ft $1,527 $2,582
8 kW Class 27 8.23 kW 562 sq ft $2,060 $3,483
10 kW Class 33 10.06 kW 687 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This Hanwha Qcells (Qidong) Co Ltd Series?

Consolidated Hanwha Qcells (Qidong) Co Ltd wattage variants sharing the Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q mechanical and cell layout.

Sibling CEC listings grouped into the Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-300Q 300.0 W 267.5 W 45.4 V 35.8 V 15.52%
Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q 305.0 W 274.2 W 45.5 V 36.1 V 15.78%

How Many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q (50.63 V at 14 F).

Computed from Voc=45.5V and beta_Voc=-0.322%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.09 V 11 panels 573.0 V 19 panels
-10 C (14 F) 50.63 V 11 panels 556.9 V 19 panels
0 C (32 F) 49.16 V 12 panels 589.9 V 20 panels
25 C (77 F STC) 45.5 V 13 panels 591.5 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q?

Competing CEC solar panels closest to Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q in nameplate wattage and Voc, starting with Auxin Solar AXN6P612T305G.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P612T305G
Auxin Solar
305.0 W Tie (0 W) 45.0 V 15.63% 90.3%
AXITEC AC-310M/156-72S
AXITEC
310.0 W +5.0 W 45.49 V 16.01% 90.2%
Chinaland Solar Energy HSE310-72M
Chinaland Solar Energy
310.0 W +5.0 W 45.4 V 16.06% 90.3%
DEHUI SOLAR POWER INC DH-72P-310W
DEHUI SOLAR POWER INC
310.0 W +5.0 W 45.6 V 16.12% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q?

Evaluate Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q (305.0 W STC, 45.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q reaches 52.09 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 562 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (562 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q 8 kW Residential Fit

Needs 27 modules (562 sq ft) with a 15 A string OCPD, offsetting ~$2,060/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 274.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q?

Multiplying Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q's 8.9 A short-circuit current by 1.56 equals 13.88 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.63 V cold Voc at 14 F and handles 8.9 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q at 11 panels on 600 V.

Is Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q rely on utility bill offset (~$2,060/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.