Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB is a 305.0 W STC (273.7 W PTC) Multi-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 15.78% efficiency, 45.7 V Voc at 25 C, and 51.44 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 305.0 W
- PTC Wattage
- 273.7 W
- Voc @ 25C
- 45.7 V
- Efficiency
- 15.78%
How Does Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB Compare Against Peer CEC Listings?
How Hanwha Qcells (Qidong) Co Ltd Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB handles rooftop heat (273.7 W PTC), 8 kW sizing, and cold winter string voltage.
Hanwha Qcells (Qidong) Co Ltd builds the Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB (Multi-c-Si) as a compact residential or specialty off-grid module delivering 157.8 W/m2 (4.13 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN6P612T305G (305.0 W), this model holds typical 89.7% PTC-to-STC thermal output (273.7 W real-world rating). Mid-range 45.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.73 A overcurrent floor served by a 15 A breaker.
Where Does Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB Fall Across Listed CEC Models?
Where Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB (305.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB?
Percentile placement of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB across power density (157.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB specifications.
305.0 W STC · Higher Than 23.9%
305.0 W STC (-80.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.78% Aperture Efficiency
Power density 157.8 W/m2 (4.13 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.44 V at -10 C (565.8 V string) and 53.08 V at -20 C (11 max).
27 Panels = 8,235 W STC
Occupies 52.2 m2 (562 sq ft) producing 7,390 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.7 * (1 + (-0.359/100) * (-10 - 25)) = 51.44 V | OCPD = 1.56 * 8.8 = 13.73 A
Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB: Voc=45.7 V, beta_Voc=-0.359%/C, Isc=8.8 A, STC=305.0 W, Area=1.933 m2.
Result: 11 panels max on 600 V (565.8 V); 27 panels for 8 kW (562 sq ft).
What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 305.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 273.7 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.7 V / 8.32 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.359 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.78% (1.933 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB (305.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.1 kW | 416 sq ft | $1,527 | $2,582 |
| 8 kW Class | 27 | 8.23 kW | 562 sq ft | $2,060 | $3,483 |
| 10 kW Class | 33 | 10.06 kW | 687 sq ft | $2,518 | $4,258 |
How Many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB Modules Fit in a Cold-Weather String?
Maximum series module counts for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.08 V | 11 panels | 583.9 V | 18 panels |
| -10 C (14 F) | 51.44 V | 11 panels | 565.8 V | 19 panels |
| 0 C (32 F) | 49.8 V | 12 panels | 597.6 V | 20 panels |
| 25 C (77 F STC) | 45.7 V | 13 panels | 594.1 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB?
Alternative CEC solar modules from competing brands near Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB (305.0 W), including Auxin Solar AXN6P612T305G.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6P612T305G Auxin Solar |
305.0 W | Tie (0 W) | 45.0 V | 15.63% | 90.3% |
| Centrosolar America DM72 310 Centrosolar America |
310.0 W | +5.0 W | 45.7 V | 15.94% | 90.8% |
| Centrosolar America TP7 310xx Centrosolar America |
310.0 W | +5.0 W | 45.7 V | 15.89% | 90.5% |
| Centrosolar America TP7S 310xx Centrosolar America |
310.0 W | +5.0 W | 45.7 V | 15.89% | 90.5% |
What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB?
Evaluate Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB (305.0 W STC, 45.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB reaches 53.08 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 562 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (562 sq ft).
- 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB 8 kW Residential Fit
Needs 27 modules (562 sq ft) with a 15 A string OCPD, offsetting ~$2,060/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 273.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB?
Multiplying Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB's 8.8 A short-circuit current by 1.56 equals 13.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.44 V cold Voc at 14 F and handles 8.8 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB at 11 panels on 600 V.
Is Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB rely on utility bill offset (~$2,060/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)