Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB — CEC Solar Module Specifications

Manufacturer: Hanwha Qcells (Qidong) Co Ltd Registry: CEC Verified Engineering Specification

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB is a 285.0 W STC (253.6 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.5% efficiency, 44.8 V Voc at 25 C, and 49.8 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
253.6 W
Voc @ 25C
44.8 V
Efficiency
14.5%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB Compare Against Peer CEC Listings?

Solar engineering breakdown for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Hanwha Qcells (Qidong) Co Ltd and peers, Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB stands 6.2 W above the 278.8 W Multi-c-Si median and typical 89.0% PTC-to-STC thermal output (253.6 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,569-$2,568/yr in baseline US bill offset. Mid-range 44.8 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB Fall Across Listed CEC Models?

Distribution marker showing Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB (285.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanwha Qcells (Qid: 285.0 W

What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB?

Dataset percentiles tracking Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB Engineering BenchmarksPercentile comparison of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention89.0%Module Efficiency14.5%

What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB?

Benchmark highlights for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,397

14.5% Aperture Efficiency

Power density 145.0 W/m2 (5.41 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.8 V at -10 C (597.6 V string) and 51.23 V at -20 C (11 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 57.0 m2 (614 sq ft) producing 7,354 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.8 * (1 + (-0.319/100) * (-10 - 25)) = 49.8 V | OCPD = 1.56 * 8.56 = 13.35 A

Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB: Voc=44.8 V, beta_Voc=-0.319%/C, Isc=8.56 A, STC=285.0 W, Area=1.966 m2.

Result: 12 panels max on 600 V (597.6 V); 29 panels for 8 kW (614 sq ft).

What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB?

Official CEC datasheet figures for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 253.6 W (89.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.2 V / 8.1 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.319 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.5% (1.966 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 466 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 614 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 762 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Hanwha Qcells (Qidong) Co Ltd Series?

Consolidated Hanwha Qcells (Qidong) Co Ltd wattage variants sharing the Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB mechanical and cell layout.

Sibling CEC listings grouped into the Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-280QB 280.0 W 249.0 W 44.7 V 35.1 V 14.24%
Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB 285.0 W 253.6 W 44.8 V 35.2 V 14.5%
Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-295QB 295.0 W 262.8 W 45.2 V 35.6 V 15.01%

How Many Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB (49.8 V at 14 F).

Computed from Voc=44.8V and beta_Voc=-0.319%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.23 V 11 panels 563.5 V 19 panels
-10 C (14 F) 49.8 V 12 panels 597.6 V 20 panels
0 C (32 F) 48.37 V 12 panels 580.4 V 20 panels
25 C (77 F STC) 44.8 V 13 panels 582.4 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB?

Competing CEC solar panels closest to Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB in nameplate wattage and Voc, starting with Gintung Energy ASEC-285G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-285G6S
Gintung Energy
285.0 W Tie (0 W) 44.69 V 14.57% 89.7%
Gintung Energy ASEC-285G6M
Gintung Energy
285.0 W Tie (0 W) 44.53 V 14.57% 89.5%
AXITEC AC-285P/156-72S
AXITEC
285.0 W Tie (0 W) 44.51 V 14.72% 90.0%
Centrosolar America DP72 285
Centrosolar America
285.0 W Tie (0 W) 44.32 V 14.66% 88.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB?

Evaluate Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB (285.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB reaches 51.23 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 614 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (614 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB 8 kW Residential Fit

Needs 29 modules (614 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-285G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 253.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB?

Multiplying Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB's 8.56 A short-circuit current by 1.56 equals 13.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.8 V cold Voc at 14 F and handles 8.56 A Isc; string inverters cap Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB at 12 panels on 600 V.

Is Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.