Guangdong Golden Glass Technologies GG270M2-36/1956x992 is a 270.0 W STC (242.7 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.92% efficiency, 44.1 V Voc at 25 C, and 48.78 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 242.7 W
- Voc @ 25C
- 44.1 V
- Efficiency
- 13.92%
How Does Guangdong Golden Glass Technologies GG270M2-36/1956x992 Compare Against Peer CEC Listings?
Solar engineering breakdown for Guangdong Golden Glass Technologies GG270M2-36/1956x992: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Guangdong Golden Glass Technologies and peers, Guangdong Golden Glass Technologies GG270M2-36/1956x992 stands 8.8 W below the 278.8 W Multi-c-Si median and typical 89.9% PTC-to-STC thermal output (242.7 W real-world rating). Sizing 6 kW (23 panels) to 10 kW (38 panels) yields $1,554-$2,568/yr in baseline US bill offset. Mid-range 44.1 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Guangdong Golden Glass Technologies GG270M2-36/1956x992 Fall Across Listed CEC Models?
Distribution marker showing Guangdong Golden Glass Technologies GG270M2-36/1956x992 (270.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Guangdong Golden Glass Technologies GG270M2-36/1956x992?
Dataset percentiles tracking Guangdong Golden Glass Technologies GG270M2-36/1956x992 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Guangdong Golden Glass Technologies GG270M2-36/1956x992?
Benchmark highlights for Guangdong Golden Glass Technologies GG270M2-36/1956x992 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.92% Aperture Efficiency
Power density 139.2 W/m2 (5.99 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.78 V at -10 C (585.4 V string) and 50.11 V at -20 C (11 max).
30 Panels = 8,100 W STC
Occupies 58.2 m2 (626 sq ft) producing 7,281 W PTC; NEC 690.8 OCPD floor is 12.64 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.1 * (1 + (-0.303/100) * (-10 - 25)) = 48.78 V | OCPD = 1.56 * 8.1 = 12.64 A
Inputs from CEC Modules.csv for Guangdong Golden Glass Technologies GG270M2-36/1956x992: Voc=44.1 V, beta_Voc=-0.303%/C, Isc=8.1 A, STC=270.0 W, Area=1.94 m2.
Result: 12 panels max on 600 V (585.4 V); 30 panels for 8 kW (626 sq ft).
What Are the Published CEC Specifications for Guangdong Golden Glass Technologies GG270M2-36/1956x992?
Official CEC datasheet figures for Guangdong Golden Glass Technologies GG270M2-36/1956x992 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 242.7 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.1 V / 7.48 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.92% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Guangdong Golden Glass Technologies GG270M2-36/1956x992 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Guangdong Golden Glass Technologies GG270M2-36/1956x992 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 480 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 626 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 794 sq ft | $2,568 | $4,342 |
How Many Guangdong Golden Glass Technologies GG270M2-36/1956x992 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Guangdong Golden Glass Technologies GG270M2-36/1956x992 (48.78 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.11 V | 11 panels | 551.2 V | 19 panels |
| -10 C (14 F) | 48.78 V | 12 panels | 585.4 V | 20 panels |
| 0 C (32 F) | 47.44 V | 12 panels | 569.3 V | 21 panels |
| 25 C (77 F STC) | 44.1 V | 13 panels | 573.3 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Guangdong Golden Glass Technologies GG270M2-36/1956x992?
Competing CEC solar panels closest to Guangdong Golden Glass Technologies GG270M2-36/1956x992 in nameplate wattage and Voc, starting with AXITEC AC-270P/156-72S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-270P/156-72S AXITEC |
270.0 W | Tie (0 W) | 44.18 V | 13.94% | 89.9% |
| Centrosolar America DP72 270 Centrosolar America |
270.0 W | Tie (0 W) | 43.85 V | 13.89% | 88.4% |
| Anhui Rinengzhongtian Semiconductor Development QJM270-72 Anhui Rinengzhongtian Semiconductor Development |
270.0 W | Tie (0 W) | 43.67 V | 13.92% | 89.6% |
| Advance Power API-M270 Advance Power |
270.0 W | Tie (0 W) | 44.64 V | 13.84% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Guangdong Golden Glass Technologies GG270M2-36/1956x992?
Evaluate Guangdong Golden Glass Technologies GG270M2-36/1956x992 (270.0 W STC, 44.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Guangdong Golden Glass Technologies GG270M2-36/1956x992 reaches 50.11 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 626 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (626 sq ft).
- 2026 tax credit baseline: cash residential installs of Guangdong Golden Glass Technologies GG270M2-36/1956x992 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Guangdong Golden Glass Technologies GG270M2-36/1956x992 8 kW Residential Fit
Needs 30 modules (626 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-270P/156-72S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 242.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Guangdong Golden Glass Technologies GG270M2-36/1956x992 by Guangdong Golden Glass Technologies grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Guangdong Golden Glass Technologies GG270M2-36/1956x992?
Multiplying Guangdong Golden Glass Technologies GG270M2-36/1956x992's 8.1 A short-circuit current by 1.56 equals 12.64 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Guangdong Golden Glass Technologies GG270M2-36/1956x992 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 48.78 V cold Voc at 14 F and handles 8.1 A Isc; string inverters cap Guangdong Golden Glass Technologies GG270M2-36/1956x992 at 12 panels on 600 V.
Is Guangdong Golden Glass Technologies GG270M2-36/1956x992 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Guangdong Golden Glass Technologies GG270M2-36/1956x992 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)