Gintung Energy GTEC-260G6S6A is a 260.0 W STC (228.1 W PTC) Mono-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.14% efficiency, 37.42 V Voc at 25 C, and 41.91 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 228.1 W
- Voc @ 25C
- 37.42 V
- Efficiency
- 16.14%
How Does Gintung Energy GTEC-260G6S6A Compare Against Peer CEC Listings?
Solar engineering breakdown for Gintung Energy GTEC-260G6S6A: PTC thermal retention, roof footprint, and cold Voc string bounds. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Across 5,889 Mono-c-Si listings from Gintung Energy and peers, Gintung Energy GTEC-260G6S6A stands 150.0 W below the 410.0 W Mono-c-Si median and typical 87.7% PTC-to-STC thermal output (228.1 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Lower 37.42 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Gintung Energy GTEC-260G6S6A Fall Across Listed CEC Models?
Distribution marker showing Gintung Energy GTEC-260G6S6A (260.0 W) relative to the 385.0 W all-CEC solar panel median. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Dataset Percentiles Define Gintung Energy GTEC-260G6S6A?
Dataset percentiles tracking Gintung Energy GTEC-260G6S6A power output, thermal retention ratio, and aperture efficiency against 21,677 models. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for Gintung Energy GTEC-260G6S6A?
Benchmark highlights for Gintung Energy GTEC-260G6S6A covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.14% Aperture Efficiency
Power density 161.4 W/m2 (3.77 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.91 V at -10 C (586.7 V string) and 43.2 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 49.9 m2 (538 sq ft) producing 7,071 W PTC; NEC 690.8 OCPD floor is 14.24 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.42 * (1 + (-0.343/100) * (-10 - 25)) = 41.91 V | OCPD = 1.56 * 9.13 = 14.24 A
Inputs from CEC Modules.csv for Gintung Energy GTEC-260G6S6A: Voc=37.42 V, beta_Voc=-0.343%/C, Isc=9.13 A, STC=260.0 W, Area=1.611 m2.
Result: 14 panels max on 600 V (586.7 V); 31 panels for 8 kW (538 sq ft).
What Are the Published CEC Specifications for Gintung Energy GTEC-260G6S6A?
Official CEC datasheet figures for Gintung Energy GTEC-260G6S6A (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 228.1 W (87.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.42 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.13 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.89 V / 8.7 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.14% (1.611 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Gintung Energy GTEC-260G6S6A Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Gintung Energy GTEC-260G6S6A modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 416 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 538 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 676 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Consolidated Gintung Energy wattage variants sharing the Gintung Energy GTEC-260G6S6A mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy GTEC-250G6S6A | 250.0 W | 219.1 W | 37.27 V | 29.59 V | 15.52% |
| Gintung Energy GTEC-255G6S6A | 255.0 W | 223.6 W | 37.35 V | 29.72 V | 15.83% |
| Gintung Energy GTEC-260G6S6A | 260.0 W | 228.1 W | 37.42 V | 29.89 V | 16.14% |
| Gintung Energy GTEC-265G6S6A | 265.0 W | 232.7 W | 37.49 V | 30.05 V | 16.45% |
| Gintung Energy GTEC-270G6S6A | 270.0 W | 237.2 W | 37.59 V | 30.2 V | 16.76% |
How Many Gintung Energy GTEC-260G6S6A Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy GTEC-260G6S6A (41.91 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.2 V | 13 panels | 561.6 V | 23 panels |
| -10 C (14 F) | 41.91 V | 14 panels | 586.7 V | 23 panels |
| 0 C (32 F) | 40.63 V | 14 panels | 568.8 V | 24 panels |
| 25 C (77 F STC) | 37.42 V | 16 panels | 598.7 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-260G6S6A?
Competing CEC solar panels closest to Gintung Energy GTEC-260G6S6A in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJM260-60.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJM260-60 Anhui Rinengzhongtian Semiconductor Development |
260.0 W | Tie (0 W) | 37.39 V | 15.98% | 90.2% |
| CSI Solar Co Ltd CS6P-260P CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.5 V | 16.79% | 92.0% |
| CSI Solar Co Ltd CS6P-260PX CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.5 V | 16.79% | 92.0% |
| Anhui Rinengzhongtian Semiconductor Development QJP260-60 Anhui Rinengzhongtian Semiconductor Development |
260.0 W | Tie (0 W) | 37.64 V | 15.98% | 90.7% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-260G6S6A?
Evaluate Gintung Energy GTEC-260G6S6A (260.0 W STC, 37.42 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-260G6S6A reaches 43.2 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 538 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (538 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-260G6S6A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy GTEC-260G6S6A 8 kW Residential Fit
Needs 31 modules (538 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM260-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 228.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy GTEC-260G6S6A by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Gintung Energy GTEC-260G6S6A?
Multiplying Gintung Energy GTEC-260G6S6A's 9.13 A short-circuit current by 1.56 equals 14.24 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Gintung Energy GTEC-260G6S6A pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.91 V cold Voc at 14 F and handles 9.13 A Isc; string inverters cap Gintung Energy GTEC-260G6S6A at 14 panels on 600 V.
Is Gintung Energy GTEC-260G6S6A eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy GTEC-260G6S6A rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)