Skip to main content
WireAndSun
Calculators
CEC PV Module

Gintung Energy ASEC-145G6S49 — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy ASEC-145G6S49 is a 145.0 W STC (126.8 W PTC) Mono-c-Si solar module ranking #21,426 of 21,677 CEC listings (below all-CEC median; higher than 1.1% of peers). It delivers 14.7% efficiency, 22.38 V Voc at 25 C, and 25.07 V cold Voc at -10 C (23 panels max per 600 V string).

STC Wattage
145.0 W
PTC Wattage
126.8 W
Voc @ 25C
22.38 V
Efficiency
14.7%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy ASEC-145G6S49 Compare Against Peer CEC Listings?

Engineering position of Gintung Energy ASEC-145G6S49 (145.0 W STC) vs. Merlin Solar Technologies Inc FXS 145L-B across 5,889 CEC Mono-c-Si solar modules.

Ranking #21,426 across 21,677 CEC solar panels (below all-CEC median; higher than 1.1% of peers), Gintung Energy ASEC-145G6S49 operates as a compact residential or specialty off-grid module sitting 265.0 W below the 410.0 W Mono-c-Si median. Lower 22.38 V string voltage fits 23 panels in series at 14 F and pairs easily with microinverters. With typical 87.4% PTC-to-STC thermal output (126.8 W real-world rating), 56 panels occupy 594 sq ft and offset roughly $2,032/yr at average US rates (or $3,437/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Gintung Energy ASEC-145G6S49 Fall Across Listed CEC Models?

Plots Gintung Energy ASEC-145G6S49 at 145.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy ASEC-145G6S49 (145.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy ASE: 145.0 W

What Dataset Percentiles Define Gintung Energy ASEC-145G6S49?

Benchmarks Gintung Energy ASEC-145G6S49 on STC wattage, thermal PTC/STC retention, and 14.7 aperture conversion efficiency against CEC peers.

Gintung Energy ASEC-145G6S49 Engineering BenchmarksPercentile comparison of Gintung Energy ASEC-145G6S49 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage145.0 WPTC/STC Retention87.4%Module Efficiency14.7%

What Do the Dataset Ranks Show for Gintung Energy ASEC-145G6S49?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Gintung Energy ASEC-145G6S49 by Gintung Energy.

Rank #21,426 / 21,677

145.0 W STC · Higher Than 1.1%

145.0 W STC (-240.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,155

14.7% Aperture Efficiency

Power density 147.1 W/m2 (5.21 percentage points below 19.91% CEC median). PTC/STC ratio: 87.4% (rank #21,562).

NEC 690.7 Limit

23 Panels Max @ -10 C (600 V)

Cold Voc reaches 25.07 V at -10 C (576.6 V string) and 25.83 V at -20 C (23 max).

8 kW Reference Array

56 Panels = 8,120 W STC

Occupies 55.2 m2 (594 sq ft) producing 7,101 W PTC; NEC 690.8 OCPD floor is 13.48 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.38 * (1 + (-0.343/100) * (-10 - 25)) = 25.07 V | OCPD = 1.56 * 8.64 = 13.48 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-145G6S49: Voc=22.38 V, beta_Voc=-0.343%/C, Isc=8.64 A, STC=145.0 W, Area=0.986 m2.

Result: 23 panels max on 600 V (576.6 V); 56 panels for 8 kW (594 sq ft).

What Are the Published CEC Specifications for Gintung Energy ASEC-145G6S49?

Laboratory test ratings recorded for Gintung Energy ASEC-145G6S49 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-145G6S49.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 145.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 126.8 W (87.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 22.38 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.64 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 17.68 V / 8.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.343 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.7% (0.986 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many Gintung Energy ASEC-145G6S49 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (594 sq ft at 8 kW), and estimated Year-1 electric bill offset for Gintung Energy ASEC-145G6S49.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 42 6.09 kW 446 sq ft $1,524 $2,577
8 kW Class 56 8.12 kW 594 sq ft $2,032 $3,437
10 kW Class 69 10.01 kW 732 sq ft $2,505 $4,236

How Many Gintung Energy ASEC-145G6S49 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Gintung Energy ASEC-145G6S49 (beta_Voc -0.343%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=22.38V and beta_Voc=-0.343%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 25.83 V 23 panels 594.1 V 38 panels
-10 C (14 F) 25.07 V 23 panels 576.6 V 39 panels
0 C (32 F) 24.3 V 24 panels 583.2 V 41 panels
25 C (77 F STC) 22.38 V 26 panels 581.9 V 44 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-145G6S49?

Closest cross-brand CEC competitors to Gintung Energy ASEC-145G6S49 matched near 145.0 W STC and 22.38 V Voc, led by Merlin Solar Technologies Inc FXS 145L-B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Merlin Solar Technologies Inc FXS 145L-B
Merlin Solar Technologies Inc
145.0 W Tie (0 W) 22.67 V 13.06% 88.3%
Merlin Solar Technologies Inc FXS 145S-B
Merlin Solar Technologies Inc
145.0 W Tie (0 W) 22.67 V 13.81% 88.4%
APOS Energy AS140
APOS Energy
140.0 W -5.0 W 22.33 V 13.69% 89.6%
Centrosolar America DP36 140
Centrosolar America
140.0 W -5.0 W 22.15 V 13.85% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-145G6S49?

Evaluate Gintung Energy ASEC-145G6S49 (145.0 W STC, 22.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-145G6S49 reaches 25.83 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 56 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 56 panels (594 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-145G6S49 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy ASEC-145G6S49 8 kW Residential Fit

Needs 56 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 23 panels (-10 C) or 23 panels (-20 C), or compare Merlin Solar Technologies Inc FXS 145L-B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 126.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-145G6S49 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Gintung Energy ASEC-145G6S49 panels fit on a 600 V winter solar string?

At -10 C (14 F), Gintung Energy ASEC-145G6S49 cold Voc rises from 22.38 V to 25.07 V (beta_Voc -0.343%/C), capping a 600 V string at 23 panels (576.6 V).

How much roof area does an 8 kW array of Gintung Energy ASEC-145G6S49 need?

An 8 kW DC system uses 56 Gintung Energy ASEC-145G6S49 modules (8,120 W STC / 7,101 W PTC), covering roughly 594 sq ft and saving ~$2,032/yr at 18.54 c/kWh.

How does Gintung Energy ASEC-145G6S49 compare against Merlin Solar Technologies Inc FXS 145L-B?

Gintung Energy ASEC-145G6S49 outputs 145.0 W STC (22.38 V Voc, rank #21,426 of 21,677), while Merlin Solar Technologies Inc FXS 145L-B delivers 145.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.