Gintung Energy ASEC-145G6S49 is a 145.0 W STC (126.8 W PTC) Mono-c-Si solar module ranking #21,426 of 21,677 CEC listings (below all-CEC median; higher than 1.1% of peers). It delivers 14.7% efficiency, 22.38 V Voc at 25 C, and 25.07 V cold Voc at -10 C (23 panels max per 600 V string).
- STC Wattage
- 145.0 W
- PTC Wattage
- 126.8 W
- Voc @ 25C
- 22.38 V
- Efficiency
- 14.7%
How Does Gintung Energy ASEC-145G6S49 Compare Against Peer CEC Listings?
Engineering position of Gintung Energy ASEC-145G6S49 (145.0 W STC) vs. Merlin Solar Technologies Inc FXS 145L-B across 5,889 CEC Mono-c-Si solar modules.
Ranking #21,426 across 21,677 CEC solar panels (below all-CEC median; higher than 1.1% of peers), Gintung Energy ASEC-145G6S49 operates as a compact residential or specialty off-grid module sitting 265.0 W below the 410.0 W Mono-c-Si median. Lower 22.38 V string voltage fits 23 panels in series at 14 F and pairs easily with microinverters. With typical 87.4% PTC-to-STC thermal output (126.8 W real-world rating), 56 panels occupy 594 sq ft and offset roughly $2,032/yr at average US rates (or $3,437/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Gintung Energy ASEC-145G6S49 Fall Across Listed CEC Models?
Plots Gintung Energy ASEC-145G6S49 at 145.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Gintung Energy ASEC-145G6S49?
Benchmarks Gintung Energy ASEC-145G6S49 on STC wattage, thermal PTC/STC retention, and 14.7 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Gintung Energy ASEC-145G6S49?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Gintung Energy ASEC-145G6S49 by Gintung Energy.
145.0 W STC · Higher Than 1.1%
145.0 W STC (-240.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.7% Aperture Efficiency
Power density 147.1 W/m2 (5.21 percentage points below 19.91% CEC median). PTC/STC ratio: 87.4% (rank #21,562).
23 Panels Max @ -10 C (600 V)
Cold Voc reaches 25.07 V at -10 C (576.6 V string) and 25.83 V at -20 C (23 max).
56 Panels = 8,120 W STC
Occupies 55.2 m2 (594 sq ft) producing 7,101 W PTC; NEC 690.8 OCPD floor is 13.48 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 22.38 * (1 + (-0.343/100) * (-10 - 25)) = 25.07 V | OCPD = 1.56 * 8.64 = 13.48 A
Inputs from CEC Modules.csv for Gintung Energy ASEC-145G6S49: Voc=22.38 V, beta_Voc=-0.343%/C, Isc=8.64 A, STC=145.0 W, Area=0.986 m2.
Result: 23 panels max on 600 V (576.6 V); 56 panels for 8 kW (594 sq ft).
What Are the Published CEC Specifications for Gintung Energy ASEC-145G6S49?
Laboratory test ratings recorded for Gintung Energy ASEC-145G6S49 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 145.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 126.8 W (87.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 22.38 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 17.68 V / 8.2 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.7% (0.986 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Gintung Energy ASEC-145G6S49 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (594 sq ft at 8 kW), and estimated Year-1 electric bill offset for Gintung Energy ASEC-145G6S49.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 42 | 6.09 kW | 446 sq ft | $1,524 | $2,577 |
| 8 kW Class | 56 | 8.12 kW | 594 sq ft | $2,032 | $3,437 |
| 10 kW Class | 69 | 10.01 kW | 732 sq ft | $2,505 | $4,236 |
How Many Gintung Energy ASEC-145G6S49 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Gintung Energy ASEC-145G6S49 (beta_Voc -0.343%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 25.83 V | 23 panels | 594.1 V | 38 panels |
| -10 C (14 F) | 25.07 V | 23 panels | 576.6 V | 39 panels |
| 0 C (32 F) | 24.3 V | 24 panels | 583.2 V | 41 panels |
| 25 C (77 F STC) | 22.38 V | 26 panels | 581.9 V | 44 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-145G6S49?
Closest cross-brand CEC competitors to Gintung Energy ASEC-145G6S49 matched near 145.0 W STC and 22.38 V Voc, led by Merlin Solar Technologies Inc FXS 145L-B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc FXS 145L-B Merlin Solar Technologies Inc |
145.0 W | Tie (0 W) | 22.67 V | 13.06% | 88.3% |
| Merlin Solar Technologies Inc FXS 145S-B Merlin Solar Technologies Inc |
145.0 W | Tie (0 W) | 22.67 V | 13.81% | 88.4% |
| APOS Energy AS140 APOS Energy |
140.0 W | -5.0 W | 22.33 V | 13.69% | 89.6% |
| Centrosolar America DP36 140 Centrosolar America |
140.0 W | -5.0 W | 22.15 V | 13.85% | 88.4% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-145G6S49?
Evaluate Gintung Energy ASEC-145G6S49 (145.0 W STC, 22.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-145G6S49 reaches 25.83 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 56 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 56 panels (594 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-145G6S49 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy ASEC-145G6S49 8 kW Residential Fit
Needs 56 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 23 panels (-10 C) or 23 panels (-20 C), or compare Merlin Solar Technologies Inc FXS 145L-B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 126.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy ASEC-145G6S49 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
How many Gintung Energy ASEC-145G6S49 panels fit on a 600 V winter solar string?
At -10 C (14 F), Gintung Energy ASEC-145G6S49 cold Voc rises from 22.38 V to 25.07 V (beta_Voc -0.343%/C), capping a 600 V string at 23 panels (576.6 V).
How much roof area does an 8 kW array of Gintung Energy ASEC-145G6S49 need?
An 8 kW DC system uses 56 Gintung Energy ASEC-145G6S49 modules (8,120 W STC / 7,101 W PTC), covering roughly 594 sq ft and saving ~$2,032/yr at 18.54 c/kWh.
How does Gintung Energy ASEC-145G6S49 compare against Merlin Solar Technologies Inc FXS 145L-B?
Gintung Energy ASEC-145G6S49 outputs 145.0 W STC (22.38 V Voc, rank #21,426 of 21,677), while Merlin Solar Technologies Inc FXS 145L-B delivers 145.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)