Skip to main content
WireAndSun
Calculators
CEC PV Module

Gintung Energy ASEC-145G6M49 — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy ASEC-145G6M49 is a 145.0 W STC (127.4 W PTC) Multi-c-Si solar module ranking #21,426 of 21,677 CEC listings (below all-CEC median; higher than 1.1% of peers). It delivers 14.7% efficiency, 22.32 V Voc at 25 C, and 25.0 V cold Voc at -10 C (24 panels max per 600 V string).

STC Wattage
145.0 W
PTC Wattage
127.4 W
Voc @ 25C
22.32 V
Efficiency
14.7%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy ASEC-145G6M49 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Gintung Energy ASEC-145G6M49 (Multi-c-Si) residential solar systems.

Homeowners evaluating Gintung Energy ASEC-145G6M49 need 42 panels for 6 kW or 56 panels (594 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 56 panels (594 sq ft). Under NEC 690.7(A), beta_Voc (-0.343%/C) pushes open-circuit voltage to 25.0 V at 14 F and 25.77 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Gintung Energy ASEC-145G6M49 Fall Across Listed CEC Models?

Comparison of Gintung Energy ASEC-145G6M49 (145.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy ASEC-145G6M49 (145.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy ASE: 145.0 W

What Dataset Percentiles Define Gintung Energy ASEC-145G6M49?

Relative ranking of Gintung Energy ASEC-145G6M49 across nameplate watts, 87.9% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Gintung Energy ASEC-145G6M49 Engineering BenchmarksPercentile comparison of Gintung Energy ASEC-145G6M49 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage145.0 WPTC/STC Retention87.9%Module Efficiency14.7%

What Do the Dataset Ranks Show for Gintung Energy ASEC-145G6M49?

Summary of Gintung Energy ASEC-145G6M49 output rank, 8 kW array size (56 panels), efficiency rating, and 600 V string limit.

Rank #21,426 / 21,677

145.0 W STC · Higher Than 1.1%

145.0 W STC (-240.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,155

14.7% Aperture Efficiency

Power density 147.1 W/m2 (5.21 percentage points below 19.91% CEC median). PTC/STC ratio: 87.9% (rank #21,435).

NEC 690.7 Limit

24 Panels Max @ -10 C (600 V)

Cold Voc reaches 25.0 V at -10 C (600.0 V string) and 25.77 V at -20 C (23 max).

8 kW Reference Array

56 Panels = 8,120 W STC

Occupies 55.2 m2 (594 sq ft) producing 7,134 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 22.32 * (1 + (-0.343/100) * (-10 - 25)) = 25.0 V | OCPD = 1.56 * 8.66 = 13.51 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-145G6M49: Voc=22.32 V, beta_Voc=-0.343%/C, Isc=8.66 A, STC=145.0 W, Area=0.986 m2.

Result: 24 panels max on 600 V (600.0 V); 56 panels for 8 kW (594 sq ft).

What Are the Published CEC Specifications for Gintung Energy ASEC-145G6M49?

Complete CEC test sheet for Gintung Energy ASEC-145G6M49 including Isc (8.66 A), Voc (22.32 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-145G6M49.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 145.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 127.4 W (87.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 22.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.66 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 17.81 V / 8.14 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.343 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.7% (0.986 m2) Array roof footprint density
Cell Count & Technology 36 cells (Multi-c-Si) Monofacial backsheet

How Many Gintung Energy ASEC-145G6M49 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Gintung Energy ASEC-145G6M49.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 42 6.09 kW 446 sq ft $1,524 $2,577
8 kW Class 56 8.12 kW 594 sq ft $2,032 $3,437
10 kW Class 69 10.01 kW 732 sq ft $2,505 $4,236

How Many Gintung Energy ASEC-145G6M49 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Gintung Energy ASEC-145G6M49 (22.32 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=22.32V and beta_Voc=-0.343%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 25.77 V 23 panels 592.7 V 38 panels
-10 C (14 F) 25.0 V 24 panels 600.0 V 40 panels
0 C (32 F) 24.23 V 24 panels 581.5 V 41 panels
25 C (77 F STC) 22.32 V 26 panels 580.3 V 44 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-145G6M49?

Four comparable CEC modules such as Merlin Solar Technologies Inc FXS 145L-B (145.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Merlin Solar Technologies Inc FXS 145L-B
Merlin Solar Technologies Inc
145.0 W Tie (0 W) 22.67 V 13.06% 88.3%
Merlin Solar Technologies Inc FXS 145S-B
Merlin Solar Technologies Inc
145.0 W Tie (0 W) 22.67 V 13.81% 88.4%
APOS Energy AS140
APOS Energy
140.0 W -5.0 W 22.33 V 13.69% 89.6%
Centrosolar America DP36 140
Centrosolar America
140.0 W -5.0 W 22.15 V 13.85% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-145G6M49?

Evaluate Gintung Energy ASEC-145G6M49 (145.0 W STC, 22.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-145G6M49 reaches 25.77 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 56 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 56 panels (594 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-145G6M49 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy ASEC-145G6M49 8 kW Residential Fit

Needs 56 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare Merlin Solar Technologies Inc FXS 145L-B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 127.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-145G6M49 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Gintung Energy ASEC-145G6M49 PTC wattage (127.4 W) lower than STC (145.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 127.4 W PTC (87.9% retention) across Gintung Energy ASEC-145G6M49's 0.986 m2 aperture.

Who should skip Gintung Energy ASEC-145G6M49 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 56 Gintung Energy ASEC-145G6M49 panels (594 sq ft) leave unusable roof gaps vs. Merlin Solar Technologies Inc FXS 145L-B.

What is the 1,000 V commercial string limit for Gintung Energy ASEC-145G6M49?

On 1,000 V commercial inverters at -10 C (25.0 V cold Voc), Gintung Energy ASEC-145G6M49 fits up to 40 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy ASEC-145G6M49.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.