Gintung Energy ASEC-145G6M49 is a 145.0 W STC (127.4 W PTC) Multi-c-Si solar module ranking #21,426 of 21,677 CEC listings (below all-CEC median; higher than 1.1% of peers). It delivers 14.7% efficiency, 22.32 V Voc at 25 C, and 25.0 V cold Voc at -10 C (24 panels max per 600 V string).
- STC Wattage
- 145.0 W
- PTC Wattage
- 127.4 W
- Voc @ 25C
- 22.32 V
- Efficiency
- 14.7%
How Does Gintung Energy ASEC-145G6M49 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Gintung Energy ASEC-145G6M49 (Multi-c-Si) residential solar systems.
Homeowners evaluating Gintung Energy ASEC-145G6M49 need 42 panels for 6 kW or 56 panels (594 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 56 panels (594 sq ft). Under NEC 690.7(A), beta_Voc (-0.343%/C) pushes open-circuit voltage to 25.0 V at 14 F and 25.77 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Gintung Energy ASEC-145G6M49 Fall Across Listed CEC Models?
Comparison of Gintung Energy ASEC-145G6M49 (145.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define Gintung Energy ASEC-145G6M49?
Relative ranking of Gintung Energy ASEC-145G6M49 across nameplate watts, 87.9% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for Gintung Energy ASEC-145G6M49?
Summary of Gintung Energy ASEC-145G6M49 output rank, 8 kW array size (56 panels), efficiency rating, and 600 V string limit.
145.0 W STC · Higher Than 1.1%
145.0 W STC (-240.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.7% Aperture Efficiency
Power density 147.1 W/m2 (5.21 percentage points below 19.91% CEC median). PTC/STC ratio: 87.9% (rank #21,435).
24 Panels Max @ -10 C (600 V)
Cold Voc reaches 25.0 V at -10 C (600.0 V string) and 25.77 V at -20 C (23 max).
56 Panels = 8,120 W STC
Occupies 55.2 m2 (594 sq ft) producing 7,134 W PTC; NEC 690.8 OCPD floor is 13.51 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 22.32 * (1 + (-0.343/100) * (-10 - 25)) = 25.0 V | OCPD = 1.56 * 8.66 = 13.51 A
Inputs from CEC Modules.csv for Gintung Energy ASEC-145G6M49: Voc=22.32 V, beta_Voc=-0.343%/C, Isc=8.66 A, STC=145.0 W, Area=0.986 m2.
Result: 24 panels max on 600 V (600.0 V); 56 panels for 8 kW (594 sq ft).
What Are the Published CEC Specifications for Gintung Energy ASEC-145G6M49?
Complete CEC test sheet for Gintung Energy ASEC-145G6M49 including Isc (8.66 A), Voc (22.32 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 145.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 127.4 W (87.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 22.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 17.81 V / 8.14 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.7% (0.986 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Multi-c-Si) | Monofacial backsheet |
How Many Gintung Energy ASEC-145G6M49 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Gintung Energy ASEC-145G6M49.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 42 | 6.09 kW | 446 sq ft | $1,524 | $2,577 |
| 8 kW Class | 56 | 8.12 kW | 594 sq ft | $2,032 | $3,437 |
| 10 kW Class | 69 | 10.01 kW | 732 sq ft | $2,505 | $4,236 |
How Many Gintung Energy ASEC-145G6M49 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Gintung Energy ASEC-145G6M49 (22.32 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 25.77 V | 23 panels | 592.7 V | 38 panels |
| -10 C (14 F) | 25.0 V | 24 panels | 600.0 V | 40 panels |
| 0 C (32 F) | 24.23 V | 24 panels | 581.5 V | 41 panels |
| 25 C (77 F STC) | 22.32 V | 26 panels | 580.3 V | 44 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-145G6M49?
Four comparable CEC modules such as Merlin Solar Technologies Inc FXS 145L-B (145.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc FXS 145L-B Merlin Solar Technologies Inc |
145.0 W | Tie (0 W) | 22.67 V | 13.06% | 88.3% |
| Merlin Solar Technologies Inc FXS 145S-B Merlin Solar Technologies Inc |
145.0 W | Tie (0 W) | 22.67 V | 13.81% | 88.4% |
| APOS Energy AS140 APOS Energy |
140.0 W | -5.0 W | 22.33 V | 13.69% | 89.6% |
| Centrosolar America DP36 140 Centrosolar America |
140.0 W | -5.0 W | 22.15 V | 13.85% | 88.4% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-145G6M49?
Evaluate Gintung Energy ASEC-145G6M49 (145.0 W STC, 22.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-145G6M49 reaches 25.77 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
- Footprint constraint: 56 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 56 panels (594 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-145G6M49 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy ASEC-145G6M49 8 kW Residential Fit
Needs 56 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare Merlin Solar Technologies Inc FXS 145L-B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 127.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy ASEC-145G6M49 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Gintung Energy ASEC-145G6M49 PTC wattage (127.4 W) lower than STC (145.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 127.4 W PTC (87.9% retention) across Gintung Energy ASEC-145G6M49's 0.986 m2 aperture.
Who should skip Gintung Energy ASEC-145G6M49 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 56 Gintung Energy ASEC-145G6M49 panels (594 sq ft) leave unusable roof gaps vs. Merlin Solar Technologies Inc FXS 145L-B.
What is the 1,000 V commercial string limit for Gintung Energy ASEC-145G6M49?
On 1,000 V commercial inverters at -10 C (25.0 V cold Voc), Gintung Energy ASEC-145G6M49 fits up to 40 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy ASEC-145G6M49.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)