Skip to main content
WireAndSun
Calculators
CEC PV Module

GermanSolar USA Inc GSM10-Agri-270W-AG — CEC Solar Module Specifications

Manufacturer: GermanSolar USA Inc Registry: CEC Verified Engineering Specification

GermanSolar USA Inc GSM10-Agri-270W-AG is a 270.0 W STC (256.4 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 22.31% efficiency, 26.24 V Voc at 25 C, and 28.33 V cold Voc at -10 C (21 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
256.4 W
Voc @ 25C
26.24 V
Efficiency
22.31%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does GermanSolar USA Inc GSM10-Agri-270W-AG Compare Against Peer CEC Listings?

Solar engineering breakdown for GermanSolar USA Inc GSM10-Agri-270W-AG: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from GermanSolar USA Inc and peers, GermanSolar USA Inc GSM10-Agri-270W-AG stands 140.0 W below the 410.0 W Mono-c-Si median and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Sizing 6 kW (23 panels) to 10 kW (38 panels) yields $1,554-$2,568/yr in baseline US bill offset. Lower 26.24 V string voltage fits 21 panels in series at 14 F and pairs easily with microinverters.

Where Does GermanSolar USA Inc GSM10-Agri-270W-AG Fall Across Listed CEC Models?

Distribution marker showing GermanSolar USA Inc GSM10-Agri-270W-AG (270.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where GermanSolar USA Inc GSM10-Agri-270W-AG (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGermanSolar USA In: 270.0 W

What Dataset Percentiles Define GermanSolar USA Inc GSM10-Agri-270W-AG?

Dataset percentiles tracking GermanSolar USA Inc GSM10-Agri-270W-AG power output, thermal retention ratio, and aperture efficiency against 21,677 models.

GermanSolar USA Inc GSM10-Agri-270W-AG Engineering BenchmarksPercentile comparison of GermanSolar USA Inc GSM10-Agri-270W-AG wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention95.0%Module Efficiency22.31%

What Do the Dataset Ranks Show for GermanSolar USA Inc GSM10-Agri-270W-AG?

Benchmark highlights for GermanSolar USA Inc GSM10-Agri-270W-AG covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,379

22.31% Aperture Efficiency

Power density 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

21 Panels Max @ -10 C (600 V)

Cold Voc reaches 28.33 V at -10 C (594.9 V string) and 28.93 V at -20 C (20 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 36.3 m2 (391 sq ft) producing 7,692 W PTC; NEC 690.8 OCPD floor is 19.83 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 26.24 * (1 + (-0.228/100) * (-10 - 25)) = 28.33 V | OCPD = 1.56 * 12.71 = 19.83 A

Inputs from CEC Modules.csv for GermanSolar USA Inc GSM10-Agri-270W-AG: Voc=26.24 V, beta_Voc=-0.228%/C, Isc=12.71 A, STC=270.0 W, Area=1.21 m2.

Result: 21 panels max on 600 V (594.9 V); 30 panels for 8 kW (391 sq ft).

What Are the Published CEC Specifications for GermanSolar USA Inc GSM10-Agri-270W-AG?

Official CEC datasheet figures for GermanSolar USA Inc GSM10-Agri-270W-AG (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for GermanSolar USA Inc GSM10-Agri-270W-AG.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 256.4 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 26.24 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 12.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 22.68 V / 11.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.228 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.31% (1.21 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many GermanSolar USA Inc GSM10-Agri-270W-AG Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many GermanSolar USA Inc GSM10-Agri-270W-AG modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 300 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 391 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 495 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This GermanSolar USA Inc Series?

Consolidated GermanSolar USA Inc wattage variants sharing the GermanSolar USA Inc GSM10-Agri-270W-AG mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the GermanSolar USA Inc GSM10-Agri-270W-AG wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
GermanSolar USA Inc GSM10-Agri-265W-AG 265.0 W 251.5 W 26.21 V 22.64 V 21.9%
GermanSolar USA Inc GSM10-Agri-270W-AG 270.0 W 256.4 W 26.24 V 22.68 V 22.31%

How Many GermanSolar USA Inc GSM10-Agri-270W-AG Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on GermanSolar USA Inc GSM10-Agri-270W-AG (28.33 V at 14 F).

Computed from Voc=26.24V and beta_Voc=-0.228%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 28.93 V 20 panels 578.6 V 34 panels
-10 C (14 F) 28.33 V 21 panels 594.9 V 35 panels
0 C (32 F) 27.74 V 21 panels 582.5 V 36 panels
25 C (77 F STC) 26.24 V 22 panels 577.3 V 38 panels

Which Cross-Brand Solar Modules Compare Closest to GermanSolar USA Inc GSM10-Agri-270W-AG?

Competing CEC solar panels closest to GermanSolar USA Inc GSM10-Agri-270W-AG in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6PH-260P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6PH-260P
CSI Solar Co Ltd
260.0 W -10.0 W 34.6 V 16.77% 92.8%
CSI Solar Co Ltd CS6PH-280P
CSI Solar Co Ltd
280.0 W +10.0 W 35.4 V 18.06% 93.0%
GCL System Integration Technology Co Ltd GCL-P6/60270
GCL System Integration Technology Co Ltd
270.0 W Tie (0 W) 38.3 V 16.6% 90.6%
AXITEC AC-270P/60S
AXITEC
270.0 W Tie (0 W) 38.31 V 16.56% 92.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for GermanSolar USA Inc GSM10-Agri-270W-AG?

Evaluate GermanSolar USA Inc GSM10-Agri-270W-AG (270.0 W STC, 26.24 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), GermanSolar USA Inc GSM10-Agri-270W-AG reaches 28.93 V per panel—exceeding 20 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 391 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (391 sq ft).
  • 2026 tax credit baseline: cash residential installs of GermanSolar USA Inc GSM10-Agri-270W-AG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

GermanSolar USA Inc GSM10-Agri-270W-AG 8 kW Residential Fit

Needs 30 modules (391 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 21 panels (-10 C) or 20 panels (-20 C), or compare CSI Solar Co Ltd CS6PH-260P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GermanSolar USA Inc GSM10-Agri-270W-AG by GermanSolar USA Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for GermanSolar USA Inc GSM10-Agri-270W-AG?

Multiplying GermanSolar USA Inc GSM10-Agri-270W-AG's 12.71 A short-circuit current by 1.56 equals 19.83 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can GermanSolar USA Inc GSM10-Agri-270W-AG pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 28.33 V cold Voc at 14 F and handles 12.71 A Isc; string inverters cap GermanSolar USA Inc GSM10-Agri-270W-AG at 21 panels on 600 V.

Is GermanSolar USA Inc GSM10-Agri-270W-AG eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GermanSolar USA Inc GSM10-Agri-270W-AG rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.