Skip to main content
WireAndSun
Calculators
CEC PV Module

GCL System Integration Technology Co Ltd GCL-P6/72300 — CEC Solar Module Specifications

Manufacturer: GCL System Integration Technology Co Ltd Registry: CEC Verified Engineering Specification

GCL System Integration Technology Co Ltd GCL-P6/72300 is a 300.0 W STC (271.2 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 15.46% efficiency, 45.0 V Voc at 25 C, and 50.01 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
300.0 W
PTC Wattage
271.2 W
Voc @ 25C
45.0 V
Efficiency
15.46%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does GCL System Integration Technology Co Ltd GCL-P6/72300 Compare Against Peer CEC Listings?

How GCL System Integration Technology Co Ltd GCL System Integration Technology Co Ltd GCL-P6/72300 handles rooftop heat (271.2 W PTC), 8 kW sizing, and cold winter string voltage.

GCL System Integration Technology Co Ltd builds the GCL System Integration Technology Co Ltd GCL-P6/72300 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 154.6 W/m2 (4.45 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN6P612T305G (305.0 W), this model holds typical 90.4% PTC-to-STC thermal output (271.2 W real-world rating). Mid-range 45.0 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.76 A overcurrent floor served by a 15 A breaker.

Where Does GCL System Integration Technology Co Ltd GCL-P6/72300 Fall Across Listed CEC Models?

Where GCL System Integration Technology Co Ltd GCL-P6/72300 (300.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where GCL System Integration Technology Co Ltd GCL-P6/72300 (300.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGCL System Integra: 300.0 W

What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-P6/72300?

Percentile placement of GCL System Integration Technology Co Ltd GCL-P6/72300 across power density (154.6 W/m2), thermal retention, and nameplate STC wattage.

GCL System Integration Technology Co Ltd GCL-P6/72300 Engineering BenchmarksPercentile comparison of GCL System Integration Technology Co Ltd GCL-P6/72300 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage300.0 WPTC/STC Retention90.4%Module Efficiency15.46%

What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-P6/72300?

Four critical engineering numbers homeowners and solar installers check first when reviewing GCL System Integration Technology Co Ltd GCL-P6/72300 specifications.

Rank #16,498 / 21,677

300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,977

15.46% Aperture Efficiency

Power density 154.6 W/m2 (4.45 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.01 V at -10 C (550.1 V string) and 51.44 V at -20 C (11 max).

8 kW Reference Array

27 Panels = 8,100 W STC

Occupies 52.4 m2 (564 sq ft) producing 7,322 W PTC; NEC 690.8 OCPD floor is 13.76 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.0 * (1 + (-0.318/100) * (-10 - 25)) = 50.01 V | OCPD = 1.56 * 8.82 = 13.76 A

Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-P6/72300: Voc=45.0 V, beta_Voc=-0.318%/C, Isc=8.82 A, STC=300.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (550.1 V); 27 panels for 8 kW (564 sq ft).

What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-P6/72300?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for GCL System Integration Technology Co Ltd GCL-P6/72300.

Official California Energy Commission (NREL SAM) test parameters for GCL System Integration Technology Co Ltd GCL-P6/72300.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 300.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 271.2 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.82 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.4 V / 8.14 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.318 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.46% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many GCL System Integration Technology Co Ltd GCL-P6/72300 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using GCL System Integration Technology Co Ltd GCL-P6/72300 (300.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.0 kW 418 sq ft $1,502 $2,539
8 kW Class 27 8.1 kW 564 sq ft $2,027 $3,428
10 kW Class 34 10.2 kW 710 sq ft $2,553 $4,317

How Many GCL System Integration Technology Co Ltd GCL-P6/72300 Modules Fit in a Cold-Weather String?

Maximum series module counts for GCL System Integration Technology Co Ltd GCL-P6/72300 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.0V and beta_Voc=-0.318%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.44 V 11 panels 565.8 V 19 panels
-10 C (14 F) 50.01 V 11 panels 550.1 V 19 panels
0 C (32 F) 48.58 V 12 panels 583.0 V 20 panels
25 C (77 F STC) 45.0 V 13 panels 585.0 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-P6/72300?

Alternative CEC solar modules from competing brands near GCL System Integration Technology Co Ltd GCL-P6/72300 (300.0 W), including Auxin Solar AXN6P612T305G.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P612T305G
Auxin Solar
305.0 W +5.0 W 45.0 V 15.63% 90.3%
Auxin Solar AXN6M612T310
Auxin Solar
310.0 W +10.0 W 45.0 V 15.89% 89.4%
AXITEC AC-310P/156-72S
AXITEC
310.0 W +10.0 W 45.05 V 16.01% 89.0%
CSI Solar Co Ltd CS6X-310P
CSI Solar Co Ltd
310.0 W +10.0 W 44.9 V 16.31% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-P6/72300?

Evaluate GCL System Integration Technology Co Ltd GCL-P6/72300 (300.0 W STC, 45.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-P6/72300 reaches 51.44 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 564 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (564 sq ft).
  • 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-P6/72300 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

GCL System Integration Technology Co Ltd GCL-P6/72300 8 kW Residential Fit

Needs 27 modules (564 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 271.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GCL System Integration Technology Co Ltd GCL-P6/72300 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for GCL System Integration Technology Co Ltd GCL-P6/72300?

Multiplying GCL System Integration Technology Co Ltd GCL-P6/72300's 8.82 A short-circuit current by 1.56 equals 13.76 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can GCL System Integration Technology Co Ltd GCL-P6/72300 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.01 V cold Voc at 14 F and handles 8.82 A Isc; string inverters cap GCL System Integration Technology Co Ltd GCL-P6/72300 at 11 panels on 600 V.

Is GCL System Integration Technology Co Ltd GCL-P6/72300 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GCL System Integration Technology Co Ltd GCL-P6/72300 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.