Skip to main content
WireAndSun
Calculators
CEC PV Module

GCL System Integration Technology Co Ltd GCL-M6/72DH370 — CEC Solar Module Specifications

Manufacturer: GCL System Integration Technology Co Ltd Registry: CEC Verified Engineering Specification

GCL System Integration Technology Co Ltd GCL-M6/72DH370 is a 370.0 W STC (342.5 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 18.69% efficiency, 48.13 V Voc at 25 C, and 53.34 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
370.0 W
PTC Wattage
342.5 W
Voc @ 25C
48.13 V
Efficiency
18.69%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does GCL System Integration Technology Co Ltd GCL-M6/72DH370 Compare Against Peer CEC Listings?

How GCL System Integration Technology Co Ltd GCL System Integration Technology Co Ltd GCL-M6/72DH370 handles rooftop heat (342.5 W PTC), 8 kW sizing, and cold winter string voltage.

GCL System Integration Technology Co Ltd builds the GCL System Integration Technology Co Ltd GCL-M6/72DH370 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 186.9 W/m2 (1.22 percentage points below 19.91% CEC median). Compared against Bluesun Solar Energy Tech CoLtd BSM370M-72 (370.0 W), this model holds strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Higher 48.13 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 15.41 A overcurrent floor served by a 20 A breaker.

Where Does GCL System Integration Technology Co Ltd GCL-M6/72DH370 Fall Across Listed CEC Models?

Where GCL System Integration Technology Co Ltd GCL-M6/72DH370 (370.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where GCL System Integration Technology Co Ltd GCL-M6/72DH370 (370.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGCL System Integra: 370.0 W

What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-M6/72DH370?

Percentile placement of GCL System Integration Technology Co Ltd GCL-M6/72DH370 across power density (186.9 W/m2), thermal retention, and nameplate STC wattage.

GCL System Integration Technology Co Ltd GCL-M6/72DH370 Engineering BenchmarksPercentile comparison of GCL System Integration Technology Co Ltd GCL-M6/72DH370 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage370.0 WPTC/STC Retention92.6%Module Efficiency18.69%

What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-M6/72DH370?

Four critical engineering numbers homeowners and solar installers check first when reviewing GCL System Integration Technology Co Ltd GCL-M6/72DH370 specifications.

Rank #11,697 / 21,677

370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,033

18.69% Aperture Efficiency

Power density 186.9 W/m2 (1.22 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.34 V at -10 C (586.7 V string) and 54.82 V at -20 C (10 max).

8 kW Reference Array

22 Panels = 8,140 W STC

Occupies 43.6 m2 (469 sq ft) producing 7,535 W PTC; NEC 690.8 OCPD floor is 15.41 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.13 * (1 + (-0.309/100) * (-10 - 25)) = 53.34 V | OCPD = 1.56 * 9.88 = 15.41 A

Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-M6/72DH370: Voc=48.13 V, beta_Voc=-0.309%/C, Isc=9.88 A, STC=370.0 W, Area=1.98 m2.

Result: 11 panels max on 600 V (586.7 V); 22 panels for 8 kW (469 sq ft).

What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-M6/72DH370?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for GCL System Integration Technology Co Ltd GCL-M6/72DH370.

Official California Energy Commission (NREL SAM) test parameters for GCL System Integration Technology Co Ltd GCL-M6/72DH370.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 370.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 342.5 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.13 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.88 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.32 V / 9.41 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.309 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.69% (1.98 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many GCL System Integration Technology Co Ltd GCL-M6/72DH370 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using GCL System Integration Technology Co Ltd GCL-M6/72DH370 (370.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.29 kW 362 sq ft $1,574 $2,662
8 kW Class 22 8.14 kW 469 sq ft $2,037 $3,445
10 kW Class 28 10.36 kW 597 sq ft $2,593 $4,385

Which Sibling Wattage & Trim Variants Belong to This GCL System Integration Technology Co Ltd Series?

All closely matched GCL System Integration Technology Co Ltd wattages and cosmetic trims sharing the GCL System Integration Technology Co Ltd GCL-M6/72DH370 architecture.

Sibling CEC listings grouped into the GCL System Integration Technology Co Ltd GCL-M6/72DH370 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
GCL System Integration Technology Co Ltd GCL-M6/72DH365 365.0 W 337.8 W 47.93 V 39.13 V 18.43%
GCL System Integration Technology Co Ltd GCL-M6/72DH370 370.0 W 342.5 W 48.13 V 39.32 V 18.69%

How Many GCL System Integration Technology Co Ltd GCL-M6/72DH370 Modules Fit in a Cold-Weather String?

Maximum series module counts for GCL System Integration Technology Co Ltd GCL-M6/72DH370 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.13V and beta_Voc=-0.309%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.82 V 10 panels 548.2 V 18 panels
-10 C (14 F) 53.34 V 11 panels 586.7 V 18 panels
0 C (32 F) 51.85 V 11 panels 570.4 V 19 panels
25 C (77 F STC) 48.13 V 12 panels 577.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-M6/72DH370?

Alternative CEC solar modules from competing brands near GCL System Integration Technology Co Ltd GCL-M6/72DH370 (370.0 W), including Bluesun Solar Energy Tech CoLtd BSM370M-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM370M-72
Bluesun Solar Energy Tech CoLtd
370.0 W Tie (0 W) 48.23 V 19.07% 91.9%
CertainTeed CT370M00-04
CertainTeed
370.0 W Tie (0 W) 47.9 V 19.66% 93.2%
Caterpillar Inc PVC370MP03H
Caterpillar Inc
370.0 W Tie (0 W) 48.6 V 19.11% 94.1%
Caterpillar Inc PVC365MP03
Caterpillar Inc
365.0 W -5.0 W 48.13 V 19.41% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-M6/72DH370?

Evaluate GCL System Integration Technology Co Ltd GCL-M6/72DH370 (370.0 W STC, 48.13 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-M6/72DH370 reaches 54.82 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 469 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (469 sq ft).
  • 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-M6/72DH370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

GCL System Integration Technology Co Ltd GCL-M6/72DH370 8 kW Residential Fit

Needs 22 modules (469 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM370M-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 342.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GCL System Integration Technology Co Ltd GCL-M6/72DH370 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for GCL System Integration Technology Co Ltd GCL-M6/72DH370?

Multiplying GCL System Integration Technology Co Ltd GCL-M6/72DH370's 9.88 A short-circuit current by 1.56 equals 15.41 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can GCL System Integration Technology Co Ltd GCL-M6/72DH370 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.34 V cold Voc at 14 F and handles 9.88 A Isc; string inverters cap GCL System Integration Technology Co Ltd GCL-M6/72DH370 at 11 panels on 600 V.

Is GCL System Integration Technology Co Ltd GCL-M6/72DH370 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GCL System Integration Technology Co Ltd GCL-M6/72DH370 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.