GCL System Integration Technology Co Ltd GCL-M6/72DH370 is a 370.0 W STC (342.5 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 18.69% efficiency, 48.13 V Voc at 25 C, and 53.34 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 370.0 W
- PTC Wattage
- 342.5 W
- Voc @ 25C
- 48.13 V
- Efficiency
- 18.69%
How Does GCL System Integration Technology Co Ltd GCL-M6/72DH370 Compare Against Peer CEC Listings?
How GCL System Integration Technology Co Ltd GCL System Integration Technology Co Ltd GCL-M6/72DH370 handles rooftop heat (342.5 W PTC), 8 kW sizing, and cold winter string voltage.
GCL System Integration Technology Co Ltd builds the GCL System Integration Technology Co Ltd GCL-M6/72DH370 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 186.9 W/m2 (1.22 percentage points below 19.91% CEC median). Compared against Bluesun Solar Energy Tech CoLtd BSM370M-72 (370.0 W), this model holds strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Higher 48.13 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 15.41 A overcurrent floor served by a 20 A breaker.
Where Does GCL System Integration Technology Co Ltd GCL-M6/72DH370 Fall Across Listed CEC Models?
Where GCL System Integration Technology Co Ltd GCL-M6/72DH370 (370.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-M6/72DH370?
Percentile placement of GCL System Integration Technology Co Ltd GCL-M6/72DH370 across power density (186.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-M6/72DH370?
Four critical engineering numbers homeowners and solar installers check first when reviewing GCL System Integration Technology Co Ltd GCL-M6/72DH370 specifications.
370.0 W STC · Higher Than 44.4%
370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.69% Aperture Efficiency
Power density 186.9 W/m2 (1.22 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.34 V at -10 C (586.7 V string) and 54.82 V at -20 C (10 max).
22 Panels = 8,140 W STC
Occupies 43.6 m2 (469 sq ft) producing 7,535 W PTC; NEC 690.8 OCPD floor is 15.41 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.13 * (1 + (-0.309/100) * (-10 - 25)) = 53.34 V | OCPD = 1.56 * 9.88 = 15.41 A
Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-M6/72DH370: Voc=48.13 V, beta_Voc=-0.309%/C, Isc=9.88 A, STC=370.0 W, Area=1.98 m2.
Result: 11 panels max on 600 V (586.7 V); 22 panels for 8 kW (469 sq ft).
What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-M6/72DH370?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for GCL System Integration Technology Co Ltd GCL-M6/72DH370.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 342.5 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.13 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.88 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.32 V / 9.41 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.309 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.69% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many GCL System Integration Technology Co Ltd GCL-M6/72DH370 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using GCL System Integration Technology Co Ltd GCL-M6/72DH370 (370.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.29 kW | 362 sq ft | $1,574 | $2,662 |
| 8 kW Class | 22 | 8.14 kW | 469 sq ft | $2,037 | $3,445 |
| 10 kW Class | 28 | 10.36 kW | 597 sq ft | $2,593 | $4,385 |
Which Sibling Wattage & Trim Variants Belong to This GCL System Integration Technology Co Ltd Series?
All closely matched GCL System Integration Technology Co Ltd wattages and cosmetic trims sharing the GCL System Integration Technology Co Ltd GCL-M6/72DH370 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/72DH365 | 365.0 W | 337.8 W | 47.93 V | 39.13 V | 18.43% |
| GCL System Integration Technology Co Ltd GCL-M6/72DH370 | 370.0 W | 342.5 W | 48.13 V | 39.32 V | 18.69% |
How Many GCL System Integration Technology Co Ltd GCL-M6/72DH370 Modules Fit in a Cold-Weather String?
Maximum series module counts for GCL System Integration Technology Co Ltd GCL-M6/72DH370 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.82 V | 10 panels | 548.2 V | 18 panels |
| -10 C (14 F) | 53.34 V | 11 panels | 586.7 V | 18 panels |
| 0 C (32 F) | 51.85 V | 11 panels | 570.4 V | 19 panels |
| 25 C (77 F STC) | 48.13 V | 12 panels | 577.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-M6/72DH370?
Alternative CEC solar modules from competing brands near GCL System Integration Technology Co Ltd GCL-M6/72DH370 (370.0 W), including Bluesun Solar Energy Tech CoLtd BSM370M-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM370M-72 Bluesun Solar Energy Tech CoLtd |
370.0 W | Tie (0 W) | 48.23 V | 19.07% | 91.9% |
| CertainTeed CT370M00-04 CertainTeed |
370.0 W | Tie (0 W) | 47.9 V | 19.66% | 93.2% |
| Caterpillar Inc PVC370MP03H Caterpillar Inc |
370.0 W | Tie (0 W) | 48.6 V | 19.11% | 94.1% |
| Caterpillar Inc PVC365MP03 Caterpillar Inc |
365.0 W | -5.0 W | 48.13 V | 19.41% | 93.4% |
What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-M6/72DH370?
Evaluate GCL System Integration Technology Co Ltd GCL-M6/72DH370 (370.0 W STC, 48.13 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-M6/72DH370 reaches 54.82 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 469 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (469 sq ft).
- 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-M6/72DH370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GCL System Integration Technology Co Ltd GCL-M6/72DH370 8 kW Residential Fit
Needs 22 modules (469 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM370M-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 342.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GCL System Integration Technology Co Ltd GCL-M6/72DH370 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for GCL System Integration Technology Co Ltd GCL-M6/72DH370?
Multiplying GCL System Integration Technology Co Ltd GCL-M6/72DH370's 9.88 A short-circuit current by 1.56 equals 15.41 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can GCL System Integration Technology Co Ltd GCL-M6/72DH370 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.34 V cold Voc at 14 F and handles 9.88 A Isc; string inverters cap GCL System Integration Technology Co Ltd GCL-M6/72DH370 at 11 panels on 600 V.
Is GCL System Integration Technology Co Ltd GCL-M6/72DH370 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GCL System Integration Technology Co Ltd GCL-M6/72DH370 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)