Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-7525A-TR1 — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-7525A-TR1 is a 525.0 W STC (488.4 W PTC) CdTe solar module ranking #4,047 of 21,677 CEC listings (top 19.4%; higher than 80.6% of peers). It delivers 18.75% efficiency, 226.1 V Voc at 25 C, and 247.62 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
525.0 W
PTC Wattage
488.4 W
Voc @ 25C
226.1 V
Efficiency
18.75%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-7525A-TR1 Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-7525A-TR1 (525.0 W STC) vs. CSI Solar Co Ltd CS3Y-505MS across 131 CEC CdTe solar modules.

Ranking #4,047 across 21,677 CEC solar panels (top 19.4%; higher than 80.6% of peers), First Solar Inc FS-7525A-TR1 operates as a large-format commercial and ground-mount module sitting 80.0 W above the 445.0 W CdTe median. Higher 226.1 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C). With strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), 16 panels occupy 482 sq ft and offset roughly $2,102/yr at average US rates (or $3,555/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does First Solar Inc FS-7525A-TR1 Fall Across Listed CEC Models?

Plots First Solar Inc FS-7525A-TR1 at 525.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-7525A-TR1 (525.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 525.0 W

What Dataset Percentiles Define First Solar Inc FS-7525A-TR1?

Benchmarks First Solar Inc FS-7525A-TR1 on STC wattage, thermal PTC/STC retention, and 18.75 aperture conversion efficiency against CEC peers.

First Solar Inc FS-7525A-TR1 Engineering BenchmarksPercentile comparison of First Solar Inc FS-7525A-TR1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage525.0 WPTC/STC Retention93.0%Module Efficiency18.75%

What Do the Dataset Ranks Show for First Solar Inc FS-7525A-TR1?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-7525A-TR1 by First Solar Inc.

Rank #4,047 / 21,677

Top 19.4% STC Output

525.0 W STC (+140.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #13,926

18.75% Aperture Efficiency

Power density 187.5 W/m2 (1.16 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 247.62 V at -10 C (495.2 V string) and 253.77 V at -20 C (2 max).

8 kW Reference Array

16 Panels = 8,400 W STC

Occupies 44.8 m2 (482 sq ft) producing 7,814 W PTC; NEC 690.8 OCPD floor is 4.74 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 226.1 * (1 + (-0.272/100) * (-10 - 25)) = 247.62 V | OCPD = 1.56 * 3.04 = 4.74 A

Inputs from CEC Modules.csv for First Solar Inc FS-7525A-TR1: Voc=226.1 V, beta_Voc=-0.272%/C, Isc=3.04 A, STC=525.0 W, Area=2.8 m2.

Result: 2 panels max on 600 V (495.2 V); 16 panels for 8 kW (482 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-7525A-TR1?

Laboratory test ratings recorded for First Solar Inc FS-7525A-TR1 (CdTe) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-7525A-TR1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 525.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 488.4 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 226.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 3.04 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 186.0 V / 2.82 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.75% (2.8 m2) Array roof footprint density
Cell Count & Technology 268 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-7525A-TR1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (482 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-7525A-TR1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.3 kW 362 sq ft $1,577 $2,666
8 kW Class 16 8.4 kW 482 sq ft $2,102 $3,555
10 kW Class 20 10.5 kW 603 sq ft $2,628 $4,444

How Many First Solar Inc FS-7525A-TR1 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-7525A-TR1 (beta_Voc -0.272%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=226.1V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 253.77 V 2 panels 507.5 V 3 panels
-10 C (14 F) 247.62 V 2 panels 495.2 V 4 panels
0 C (32 F) 241.47 V 2 panels 482.9 V 4 panels
25 C (77 F STC) 226.1 V 2 panels 452.2 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7525A-TR1?

Closest cross-brand CEC competitors to First Solar Inc FS-7525A-TR1 matched near 525.0 W STC and 226.1 V Voc, led by CSI Solar Co Ltd CS3Y-505MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3Y-505MS
CSI Solar Co Ltd
505.0 W -20.0 W 53.9 V 22.05% 93.7%
Bila Solar Inc BF530J-12X12UW
Bila Solar Inc
530.0 W +5.0 W 49.94 V 19.7% 93.3%
Bila Solar Inc DF530J-12X12UW
Bila Solar Inc
530.0 W +5.0 W 49.86 V 19.7% 93.7%
Boviet Solar Technology Co Ltd BVM7612M-520-H-HC
Boviet Solar Technology Co Ltd
520.0 W -5.0 W 49.39 V 20.04% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7525A-TR1?

Evaluate First Solar Inc FS-7525A-TR1 (525.0 W STC, 226.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7525A-TR1 reaches 253.77 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 482 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7525A-TR1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-7525A-TR1 8 kW Residential Fit

Needs 16 modules (482 sq ft) with a 15 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-505MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 488.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-7525A-TR1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many First Solar Inc FS-7525A-TR1 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-7525A-TR1 cold Voc rises from 226.1 V to 247.62 V (beta_Voc -0.272%/C), capping a 600 V string at 2 panels (495.2 V).

How much roof area does an 8 kW array of First Solar Inc FS-7525A-TR1 need?

An 8 kW DC system uses 16 First Solar Inc FS-7525A-TR1 modules (8,400 W STC / 7,814 W PTC), covering roughly 482 sq ft and saving ~$2,102/yr at 18.54 c/kWh.

How does First Solar Inc FS-7525A-TR1 compare against CSI Solar Co Ltd CS3Y-505MS?

First Solar Inc FS-7525A-TR1 outputs 525.0 W STC (226.1 V Voc, rank #4,047 of 21,677), while CSI Solar Co Ltd CS3Y-505MS delivers 505.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.