First Solar Inc FS-7520A-FT1 is a 520.0 W STC (483.7 W PTC) CdTe solar module ranking #4,199 of 21,677 CEC listings (top 19.9%; higher than 80.1% of peers). It delivers 18.57% efficiency, 225.6 V Voc at 25 C, and 247.08 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 520.0 W
- PTC Wattage
- 483.7 W
- Voc @ 25C
- 225.6 V
- Efficiency
- 18.57%
How Does First Solar Inc FS-7520A-FT1 Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-7520A-FT1: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 131 CdTe listings from First Solar Inc and peers, First Solar Inc FS-7520A-FT1 stands 75.0 W above the 445.0 W CdTe median and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677). Sizing 6 kW (12 panels) to 10 kW (20 panels) yields $1,562-$2,603/yr in baseline US bill offset. Higher 225.6 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).
Where Does First Solar Inc FS-7520A-FT1 Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-7520A-FT1 (520.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-7520A-FT1?
Dataset percentiles tracking First Solar Inc FS-7520A-FT1 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-7520A-FT1?
Benchmark highlights for First Solar Inc FS-7520A-FT1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 19.9% STC Output
520.0 W STC (+135.0 W vs all-CEC median) vs 445.0 W CdTe median.
18.57% Aperture Efficiency
Power density 185.7 W/m2 (1.34 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 247.08 V at -10 C (494.2 V string) and 253.21 V at -20 C (2 max).
16 Panels = 8,320 W STC
Occupies 44.8 m2 (482 sq ft) producing 7,739 W PTC; NEC 690.8 OCPD floor is 4.74 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 225.6 * (1 + (-0.272/100) * (-10 - 25)) = 247.08 V | OCPD = 1.56 * 3.04 = 4.74 A
Inputs from CEC Modules.csv for First Solar Inc FS-7520A-FT1: Voc=225.6 V, beta_Voc=-0.272%/C, Isc=3.04 A, STC=520.0 W, Area=2.8 m2.
Result: 2 panels max on 600 V (494.2 V); 16 panels for 8 kW (482 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-7520A-FT1?
Official CEC datasheet figures for First Solar Inc FS-7520A-FT1 (CdTe) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 520.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 483.7 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 225.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 3.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 185.2 V / 2.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.57% (2.8 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-7520A-FT1 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-7520A-FT1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.24 kW | 362 sq ft | $1,562 | $2,641 |
| 8 kW Class | 16 | 8.32 kW | 482 sq ft | $2,082 | $3,521 |
| 10 kW Class | 20 | 10.4 kW | 603 sq ft | $2,603 | $4,402 |
How Many First Solar Inc FS-7520A-FT1 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-7520A-FT1 (247.08 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 253.21 V | 2 panels | 506.4 V | 3 panels |
| -10 C (14 F) | 247.08 V | 2 panels | 494.2 V | 4 panels |
| 0 C (32 F) | 240.94 V | 2 panels | 481.9 V | 4 panels |
| 25 C (77 F STC) | 225.6 V | 2 panels | 451.2 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-7520A-FT1?
Competing CEC solar panels closest to First Solar Inc FS-7520A-FT1 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3Y-505MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-505MS CSI Solar Co Ltd |
505.0 W | -15.0 W | 53.9 V | 22.05% | 93.7% |
| Boviet Solar Technology Co Ltd BVM7612M-520-H-HC Boviet Solar Technology Co Ltd |
520.0 W | Tie (0 W) | 49.39 V | 20.04% | 93.8% |
| AXITEC AC-520MH/144VB AXITEC |
520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |
| ELITE Solar ET-M772BH520BB ELITE Solar |
520.0 W | Tie (0 W) | 49.0 V | 20.31% | 93.7% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-7520A-FT1?
Evaluate First Solar Inc FS-7520A-FT1 (520.0 W STC, 225.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-7520A-FT1 reaches 253.21 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 482 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (482 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-7520A-FT1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-7520A-FT1 8 kW Residential Fit
Needs 16 modules (482 sq ft) with a 15 A string OCPD, offsetting ~$2,082/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-505MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 483.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-7520A-FT1 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-7520A-FT1?
Multiplying First Solar Inc FS-7520A-FT1's 3.04 A short-circuit current by 1.56 equals 4.74 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-7520A-FT1 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 247.08 V cold Voc at 14 F and handles 3.04 A Isc; string inverters cap First Solar Inc FS-7520A-FT1 at 2 panels on 600 V.
Is First Solar Inc FS-7520A-FT1 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-7520A-FT1 rely on utility bill offset (~$2,082/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)