First Solar Inc FS-6395A — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-6395A is a 395.0 W STC (370.4 W PTC) CdTe solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 15.93% efficiency, 215.4 V Voc at 25 C, and 236.28 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
370.4 W
Voc @ 25C
215.4 V
Efficiency
15.93%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6395A Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-6395A (395.0 W STC) vs. CSI Solar Co Ltd CS1Y-390MS across 131 CEC CdTe solar modules.

Ranking #9,869 across 21,677 CEC solar panels (top 47.6%; higher than 52.4% of peers), First Solar Inc FS-6395A operates as a modern high-density residential and light-commercial module sitting 50.0 W below the 445.0 W CdTe median. Higher 215.4 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C). With strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677), 21 panels occupy 561 sq ft and offset roughly $2,075/yr at average US rates (or $3,509/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does First Solar Inc FS-6395A Fall Across Listed CEC Models?

Plots First Solar Inc FS-6395A at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6395A (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 395.0 W

What Dataset Percentiles Define First Solar Inc FS-6395A?

Benchmarks First Solar Inc FS-6395A on STC wattage, thermal PTC/STC retention, and 15.93 aperture conversion efficiency against CEC peers.

First Solar Inc FS-6395A Engineering BenchmarksPercentile comparison of First Solar Inc FS-6395A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention93.8%Module Efficiency15.93%

What Do the Dataset Ranks Show for First Solar Inc FS-6395A?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-6395A by First Solar Inc.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #18,285

15.93% Aperture Efficiency

Power density 159.3 W/m2 (3.98 percentage points below 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 236.28 V at -10 C (472.6 V string) and 242.25 V at -20 C (2 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 52.1 m2 (561 sq ft) producing 7,778 W PTC; NEC 690.8 OCPD floor is 3.9 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 215.4 * (1 + (-0.277/100) * (-10 - 25)) = 236.28 V | OCPD = 1.56 * 2.5 = 3.9 A

Inputs from CEC Modules.csv for First Solar Inc FS-6395A: Voc=215.4 V, beta_Voc=-0.277%/C, Isc=2.5 A, STC=395.0 W, Area=2.48 m2.

Result: 2 panels max on 600 V (472.6 V); 21 panels for 8 kW (561 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6395A?

Laboratory test ratings recorded for First Solar Inc FS-6395A (CdTe) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6395A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 370.4 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 215.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 175.0 V / 2.26 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.277 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.93% (2.48 m2) Array roof footprint density
Cell Count & Technology 264 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6395A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (561 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-6395A.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 427 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 561 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 694 sq ft $2,570 $4,347

How Many First Solar Inc FS-6395A Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-6395A (beta_Voc -0.277%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=215.4V and beta_Voc=-0.277%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 242.25 V 2 panels 484.5 V 4 panels
-10 C (14 F) 236.28 V 2 panels 472.6 V 4 panels
0 C (32 F) 230.32 V 2 panels 460.6 V 4 panels
25 C (77 F STC) 215.4 V 2 panels 430.8 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6395A?

Closest cross-brand CEC competitors to First Solar Inc FS-6395A matched near 395.0 W STC and 215.4 V Voc, led by CSI Solar Co Ltd CS1Y-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-390MS
CSI Solar Co Ltd
390.0 W -5.0 W 51.9 V 20.0% 94.0%
BYD Company Limited BYD415MIK-36
BYD Company Limited
395.0 W Tie (0 W) 50.06 V 19.65% 93.9%
ELITE Solar ET-M672BH395GL
ELITE Solar
395.0 W Tie (0 W) 49.6 V 19.36% 93.2%
ELITE Solar ET-M672BH395WW
ELITE Solar
395.0 W Tie (0 W) 49.5 V 19.85% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6395A?

Evaluate First Solar Inc FS-6395A (395.0 W STC, 215.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6395A reaches 242.25 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 561 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (561 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6395A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6395A 8 kW Residential Fit

Needs 21 modules (561 sq ft) with a 15 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 370.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6395A by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many First Solar Inc FS-6395A panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6395A cold Voc rises from 215.4 V to 236.28 V (beta_Voc -0.277%/C), capping a 600 V string at 2 panels (472.6 V).

How much roof area does an 8 kW array of First Solar Inc FS-6395A need?

An 8 kW DC system uses 21 First Solar Inc FS-6395A modules (8,295 W STC / 7,778 W PTC), covering roughly 561 sq ft and saving ~$2,075/yr at 18.54 c/kWh.

How does First Solar Inc FS-6395A compare against CSI Solar Co Ltd CS1Y-390MS?

First Solar Inc FS-6395A outputs 395.0 W STC (215.4 V Voc, rank #9,869 of 21,677), while CSI Solar Co Ltd CS1Y-390MS delivers 390.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.