First Solar Inc FS-6395 is a 395.0 W STC (368.0 W PTC) CdTe solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 15.93% efficiency, 215.4 V Voc at 25 C, and 236.43 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 368.0 W
- Voc @ 25C
- 215.4 V
- Efficiency
- 15.93%
How Does First Solar Inc FS-6395 Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-6395: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 131 CdTe listings from First Solar Inc and peers, First Solar Inc FS-6395 stands 50.0 W below the 445.0 W CdTe median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,582-$2,570/yr in baseline US bill offset. Higher 215.4 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).
Where Does First Solar Inc FS-6395 Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-6395 (395.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-6395?
Dataset percentiles tracking First Solar Inc FS-6395 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-6395?
Benchmark highlights for First Solar Inc FS-6395 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 445.0 W CdTe median.
15.93% Aperture Efficiency
Power density 159.3 W/m2 (3.98 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 236.43 V at -10 C (472.9 V string) and 242.44 V at -20 C (2 max).
21 Panels = 8,295 W STC
Occupies 52.1 m2 (561 sq ft) producing 7,728 W PTC; NEC 690.8 OCPD floor is 3.9 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 215.4 * (1 + (-0.279/100) * (-10 - 25)) = 236.43 V | OCPD = 1.56 * 2.5 = 3.9 A
Inputs from CEC Modules.csv for First Solar Inc FS-6395: Voc=215.4 V, beta_Voc=-0.279%/C, Isc=2.5 A, STC=395.0 W, Area=2.48 m2.
Result: 2 panels max on 600 V (472.9 V); 21 panels for 8 kW (561 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6395?
Official CEC datasheet figures for First Solar Inc FS-6395 (CdTe) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 368.0 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 215.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 175.0 V / 2.26 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.93% (2.48 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6395 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-6395 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 427 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 561 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 694 sq ft | $2,570 | $4,347 |
How Many First Solar Inc FS-6395 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6395 (236.43 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 242.44 V | 2 panels | 484.9 V | 4 panels |
| -10 C (14 F) | 236.43 V | 2 panels | 472.9 V | 4 panels |
| 0 C (32 F) | 230.42 V | 2 panels | 460.8 V | 4 panels |
| 25 C (77 F STC) | 215.4 V | 2 panels | 430.8 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6395?
Competing CEC solar panels closest to First Solar Inc FS-6395 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS1Y-390MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS1Y-390MS CSI Solar Co Ltd |
390.0 W | -5.0 W | 51.9 V | 20.0% | 94.0% |
| BYD Company Limited BYD415MIK-36 BYD Company Limited |
395.0 W | Tie (0 W) | 50.06 V | 19.65% | 93.9% |
| ELITE Solar ET-M672BH395GL ELITE Solar |
395.0 W | Tie (0 W) | 49.6 V | 19.36% | 93.2% |
| ELITE Solar ET-M672BH395WW ELITE Solar |
395.0 W | Tie (0 W) | 49.5 V | 19.85% | 93.3% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6395?
Evaluate First Solar Inc FS-6395 (395.0 W STC, 215.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6395 reaches 242.44 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 561 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (561 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6395 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6395 8 kW Residential Fit
Needs 21 modules (561 sq ft) with a 15 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 368.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6395 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6395?
Multiplying First Solar Inc FS-6395's 2.5 A short-circuit current by 1.56 equals 3.9 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-6395 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 236.43 V cold Voc at 14 F and handles 2.5 A Isc; string inverters cap First Solar Inc FS-6395 at 2 panels on 600 V.
Is First Solar Inc FS-6395 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6395 rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)