Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-6390 — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-6390 is a 390.0 W STC (363.2 W PTC) CdTe solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 15.73% efficiency, 214.8 V Voc at 25 C, and 235.78 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
363.2 W
Voc @ 25C
214.8 V
Efficiency
15.73%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6390 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6390 (CdTe) residential solar systems.

Homeowners evaluating First Solar Inc FS-6390 need 16 panels for 6 kW or 21 panels (561 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 21 panels (561 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.279%/C) pushes open-circuit voltage to 235.78 V at 14 F and 241.77 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does First Solar Inc FS-6390 Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-6390 (390.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6390 (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 390.0 W

What Dataset Percentiles Define First Solar Inc FS-6390?

Relative ranking of First Solar Inc FS-6390 across nameplate watts, 93.1% PTC thermal ratio, and module aperture efficiency.

First Solar Inc FS-6390 Engineering BenchmarksPercentile comparison of First Solar Inc FS-6390 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention93.1%Module Efficiency15.73%

What Do the Dataset Ranks Show for First Solar Inc FS-6390?

Summary of First Solar Inc FS-6390 output rank, 8 kW array size (21 panels), efficiency rating, and 600 V string limit.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #18,566

15.73% Aperture Efficiency

Power density 157.3 W/m2 (4.18 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 235.78 V at -10 C (471.6 V string) and 241.77 V at -20 C (2 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 52.1 m2 (561 sq ft) producing 7,627 W PTC; NEC 690.8 OCPD floor is 3.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 214.8 * (1 + (-0.279/100) * (-10 - 25)) = 235.78 V | OCPD = 1.56 * 2.49 = 3.88 A

Inputs from CEC Modules.csv for First Solar Inc FS-6390: Voc=214.8 V, beta_Voc=-0.279%/C, Isc=2.49 A, STC=390.0 W, Area=2.48 m2.

Result: 2 panels max on 600 V (471.6 V); 21 panels for 8 kW (561 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6390?

Complete CEC test sheet for First Solar Inc FS-6390 including Isc (2.49 A), Voc (214.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6390.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 363.2 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 214.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.49 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 173.9 V / 2.24 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.279 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.73% (2.48 m2) Array roof footprint density
Cell Count & Technology 264 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6390 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6390.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 427 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 561 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 694 sq ft $2,538 $4,292

How Many First Solar Inc FS-6390 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-6390 (214.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=214.8V and beta_Voc=-0.279%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 241.77 V 2 panels 483.5 V 4 panels
-10 C (14 F) 235.78 V 2 panels 471.6 V 4 panels
0 C (32 F) 229.78 V 2 panels 459.6 V 4 panels
25 C (77 F STC) 214.8 V 2 panels 429.6 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6390?

Four comparable CEC modules such as CSI Solar Co Ltd CS1Y-390MS (390.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 51.9 V 20.0% 94.0%
BYD Company Limited BYD415MIK-36
BYD Company Limited
395.0 W +5.0 W 50.06 V 19.65% 93.9%
ELITE Solar ET-M672BH395GL
ELITE Solar
395.0 W +5.0 W 49.6 V 19.36% 93.2%
ELITE Solar ET-M672BH395WW
ELITE Solar
395.0 W +5.0 W 49.5 V 19.85% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6390?

Evaluate First Solar Inc FS-6390 (390.0 W STC, 214.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6390 reaches 241.77 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 561 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (561 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6390 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6390 8 kW Residential Fit

Needs 21 modules (561 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 363.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6390 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is First Solar Inc FS-6390 PTC wattage (363.2 W) lower than STC (390.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 363.2 W PTC (93.1% retention) across First Solar Inc FS-6390's 2.48 m2 aperture.

Who should skip First Solar Inc FS-6390 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 First Solar Inc FS-6390 panels (561 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS1Y-390MS.

What is the 1,000 V commercial string limit for First Solar Inc FS-6390?

On 1,000 V commercial inverters at -10 C (235.78 V cold Voc), First Solar Inc FS-6390 fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6390.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.