Exiom Solution S A EX410-108BMH is a 410.0 W STC (382.4 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.5 V Voc at 25 C, and 40.95 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 382.4 W
- Voc @ 25C
- 37.5 V
- Efficiency
- 21.13%
How Does Exiom Solution S A EX410-108BMH Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Exiom Solution S A EX410-108BMH (Mono-c-Si) residential solar systems.
Exiom Solution S A EX410-108BMH delivers 211.3 W/m2 (1.22 percentage points above 19.91% CEC median) and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 41.94 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with ASTORIOS Holding Inc ASTR108BDG-410W-US (410.0 W).
Where Does Exiom Solution S A EX410-108BMH Fall Across Listed CEC Models?
Comparison of Exiom Solution S A EX410-108BMH (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Exiom Solution S A EX410-108BMH?
Relative ranking of Exiom Solution S A EX410-108BMH across nameplate watts, 93.3% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Exiom Solution S A EX410-108BMH?
Summary of Exiom Solution S A EX410-108BMH output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.13% Aperture Efficiency
Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.95 V at -10 C (573.3 V string) and 41.94 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,648 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.5 * (1 + (-0.263/100) * (-10 - 25)) = 40.95 V | OCPD = 1.56 * 13.86 = 21.62 A
Inputs from CEC Modules.csv for Exiom Solution S A EX410-108BMH: Voc=37.5 V, beta_Voc=-0.263%/C, Isc=13.86 A, STC=410.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (573.3 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for Exiom Solution S A EX410-108BMH?
Complete CEC test sheet for Exiom Solution S A EX410-108BMH including Isc (13.86 A), Voc (37.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 382.4 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.6 V / 13.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.13% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Exiom Solution S A EX410-108BMH Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Exiom Solution S A EX410-108BMH.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 313 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 418 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 522 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This Exiom Solution S A Series?
Related Exiom Solution S A power steps and black/silver trims consolidated into this Exiom Solution S A EX410-108BMH series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Exiom Solution S A EX405-108BMH | 405.0 W | 377.6 W | 37.4 V | 31.4 V | 20.88% |
| Exiom Solution S A EX410-108BMH | 410.0 W | 382.4 W | 37.5 V | 31.6 V | 21.13% |
How Many Exiom Solution S A EX410-108BMH Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Exiom Solution S A EX410-108BMH (37.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.94 V | 14 panels | 587.2 V | 23 panels |
| -10 C (14 F) | 40.95 V | 14 panels | 573.3 V | 24 panels |
| 0 C (32 F) | 39.97 V | 15 panels | 599.5 V | 25 panels |
| 25 C (77 F STC) | 37.5 V | 16 panels | 600.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Exiom Solution S A EX410-108BMH?
Four comparable CEC modules such as ASTORIOS Holding Inc ASTR108BDG-410W-US (410.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ASTORIOS Holding Inc ASTR108BDG-410W-US ASTORIOS Holding Inc |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| AXITEC AC-410MBT/108US AXITEC |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 Elin Energy (Sirius PV) |
410.0 W | Tie (0 W) | 37.32 V | 21.13% | 94.4% |
| CSI Solar Co Ltd CS6R-410MB CSI Solar Co Ltd |
410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Exiom Solution S A EX410-108BMH?
Evaluate Exiom Solution S A EX410-108BMH (410.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Exiom Solution S A EX410-108BMH reaches 41.94 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Exiom Solution S A EX410-108BMH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Exiom Solution S A EX410-108BMH 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-410W-US.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 382.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Exiom Solution S A EX410-108BMH by Exiom Solution S A grounded in CEC test data and NEC 690.7/690.8 limits.
How many Exiom Solution S A EX410-108BMH panels fit on a 600 V winter solar string?
At -10 C (14 F), Exiom Solution S A EX410-108BMH cold Voc rises from 37.5 V to 40.95 V (beta_Voc -0.263%/C), capping a 600 V string at 14 panels (573.3 V).
How much roof area does an 8 kW array of Exiom Solution S A EX410-108BMH need?
An 8 kW DC system uses 20 Exiom Solution S A EX410-108BMH modules (8,200 W STC / 7,648 W PTC), covering roughly 418 sq ft and saving ~$2,052/yr at 18.54 c/kWh.
How does Exiom Solution S A EX410-108BMH compare against ASTORIOS Holding Inc ASTR108BDG-410W-US?
Exiom Solution S A EX410-108BMH outputs 410.0 W STC (37.5 V Voc, rank #8,539 of 21,677), while ASTORIOS Holding Inc ASTR108BDG-410W-US delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)