Manufacturer: Exiom Solution S A Registry: CEC Verified Engineering Specification

Exiom Solution S A EX410-108BMH is a 410.0 W STC (382.4 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.5 V Voc at 25 C, and 40.95 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
382.4 W
Voc @ 25C
37.5 V
Efficiency
21.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Exiom Solution S A EX410-108BMH Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Exiom Solution S A EX410-108BMH (Mono-c-Si) residential solar systems.

Exiom Solution S A EX410-108BMH delivers 211.3 W/m2 (1.22 percentage points above 19.91% CEC median) and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 41.94 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with ASTORIOS Holding Inc ASTR108BDG-410W-US (410.0 W).

Where Does Exiom Solution S A EX410-108BMH Fall Across Listed CEC Models?

Comparison of Exiom Solution S A EX410-108BMH (410.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Exiom Solution S A EX410-108BMH (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCExiom Solution S A: 410.0 W

What Dataset Percentiles Define Exiom Solution S A EX410-108BMH?

Relative ranking of Exiom Solution S A EX410-108BMH across nameplate watts, 93.3% PTC thermal ratio, and module aperture efficiency.

Exiom Solution S A EX410-108BMH Engineering BenchmarksPercentile comparison of Exiom Solution S A EX410-108BMH wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.3%Module Efficiency21.13%

What Do the Dataset Ranks Show for Exiom Solution S A EX410-108BMH?

Summary of Exiom Solution S A EX410-108BMH output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,767

21.13% Aperture Efficiency

Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.95 V at -10 C (573.3 V string) and 41.94 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,648 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.5 * (1 + (-0.263/100) * (-10 - 25)) = 40.95 V | OCPD = 1.56 * 13.86 = 21.62 A

Inputs from CEC Modules.csv for Exiom Solution S A EX410-108BMH: Voc=37.5 V, beta_Voc=-0.263%/C, Isc=13.86 A, STC=410.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (573.3 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for Exiom Solution S A EX410-108BMH?

Complete CEC test sheet for Exiom Solution S A EX410-108BMH including Isc (13.86 A), Voc (37.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Exiom Solution S A EX410-108BMH.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 382.4 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.86 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.6 V / 13.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.13% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many Exiom Solution S A EX410-108BMH Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Exiom Solution S A EX410-108BMH.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 313 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 418 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 522 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Exiom Solution S A Series?

Related Exiom Solution S A power steps and black/silver trims consolidated into this Exiom Solution S A EX410-108BMH series guide.

Sibling CEC listings grouped into the Exiom Solution S A EX410-108BMH wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Exiom Solution S A EX405-108BMH 405.0 W 377.6 W 37.4 V 31.4 V 20.88%
Exiom Solution S A EX410-108BMH 410.0 W 382.4 W 37.5 V 31.6 V 21.13%

How Many Exiom Solution S A EX410-108BMH Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Exiom Solution S A EX410-108BMH (37.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.5V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.94 V 14 panels 587.2 V 23 panels
-10 C (14 F) 40.95 V 14 panels 573.3 V 24 panels
0 C (32 F) 39.97 V 15 panels 599.5 V 25 panels
25 C (77 F STC) 37.5 V 16 panels 600.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Exiom Solution S A EX410-108BMH?

Four comparable CEC modules such as ASTORIOS Holding Inc ASTR108BDG-410W-US (410.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ASTORIOS Holding Inc ASTR108BDG-410W-US
ASTORIOS Holding Inc
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
AXITEC AC-410MBT/108US
AXITEC
410.0 W Tie (0 W) 37.5 V 21.13% 93.0%
Elin Energy (Sirius PV) ELNSM54M-HC-BF-410
Elin Energy (Sirius PV)
410.0 W Tie (0 W) 37.32 V 21.13% 94.4%
CSI Solar Co Ltd CS6R-410MB
CSI Solar Co Ltd
410.0 W Tie (0 W) 38.0 V 21.69% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Exiom Solution S A EX410-108BMH?

Evaluate Exiom Solution S A EX410-108BMH (410.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Exiom Solution S A EX410-108BMH reaches 41.94 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Exiom Solution S A EX410-108BMH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Exiom Solution S A EX410-108BMH 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-410W-US.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 382.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Exiom Solution S A EX410-108BMH by Exiom Solution S A grounded in CEC test data and NEC 690.7/690.8 limits.

How many Exiom Solution S A EX410-108BMH panels fit on a 600 V winter solar string?

At -10 C (14 F), Exiom Solution S A EX410-108BMH cold Voc rises from 37.5 V to 40.95 V (beta_Voc -0.263%/C), capping a 600 V string at 14 panels (573.3 V).

How much roof area does an 8 kW array of Exiom Solution S A EX410-108BMH need?

An 8 kW DC system uses 20 Exiom Solution S A EX410-108BMH modules (8,200 W STC / 7,648 W PTC), covering roughly 418 sq ft and saving ~$2,052/yr at 18.54 c/kWh.

How does Exiom Solution S A EX410-108BMH compare against ASTORIOS Holding Inc ASTR108BDG-410W-US?

Exiom Solution S A EX410-108BMH outputs 410.0 W STC (37.5 V Voc, rank #8,539 of 21,677), while ASTORIOS Holding Inc ASTR108BDG-410W-US delivers 410.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.