Exiom Solution S A EX545-144BMH-DG is a 545.0 W STC (509.1 W PTC) Mono-c-Si solar module ranking #2,998 of 21,677 CEC listings (top 15.1%; higher than 84.9% of peers). It delivers 21.12% efficiency, 49.8 V Voc at 25 C, and 54.31 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 545.0 W
- PTC Wattage
- 509.1 W
- Voc @ 25C
- 49.8 V
- Efficiency
- 21.12%
How Does Exiom Solution S A EX545-144BMH-DG Compare Against Peer CEC Listings?
Solar engineering breakdown for Exiom Solution S A EX545-144BMH-DG: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Exiom Solution S A and peers, Exiom Solution S A EX545-144BMH-DG stands 135.0 W above the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (12 panels) to 10 kW (19 panels) yields $1,637-$2,593/yr in baseline US bill offset. Higher 49.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Exiom Solution S A EX545-144BMH-DG Fall Across Listed CEC Models?
Distribution marker showing Exiom Solution S A EX545-144BMH-DG (545.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Exiom Solution S A EX545-144BMH-DG?
Dataset percentiles tracking Exiom Solution S A EX545-144BMH-DG power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Exiom Solution S A EX545-144BMH-DG?
Benchmark highlights for Exiom Solution S A EX545-144BMH-DG covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 15.1% STC Output
545.0 W STC (+160.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.12% Aperture Efficiency
Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.31 V at -10 C (597.4 V string) and 55.6 V at -20 C (10 max).
15 Panels = 8,175 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,636 W PTC; NEC 690.8 OCPD floor is 21.72 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.8 * (1 + (-0.259/100) * (-10 - 25)) = 54.31 V | OCPD = 1.56 * 13.92 = 21.72 A
Inputs from CEC Modules.csv for Exiom Solution S A EX545-144BMH-DG: Voc=49.8 V, beta_Voc=-0.259%/C, Isc=13.92 A, STC=545.0 W, Area=2.58 m2.
Result: 11 panels max on 600 V (597.4 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Exiom Solution S A EX545-144BMH-DG?
Official CEC datasheet figures for Exiom Solution S A EX545-144BMH-DG (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 545.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 509.1 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.92 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.8 V / 13.04 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.259 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.12% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Exiom Solution S A EX545-144BMH-DG Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Exiom Solution S A EX545-144BMH-DG modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.54 kW | 333 sq ft | $1,637 | $2,768 |
| 8 kW Class | 15 | 8.18 kW | 417 sq ft | $2,047 | $3,462 |
| 10 kW Class | 19 | 10.36 kW | 528 sq ft | $2,593 | $4,385 |
How Many Exiom Solution S A EX545-144BMH-DG Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Exiom Solution S A EX545-144BMH-DG (54.31 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.6 V | 10 panels | 556.0 V | 17 panels |
| -10 C (14 F) | 54.31 V | 11 panels | 597.4 V | 18 panels |
| 0 C (32 F) | 53.02 V | 11 panels | 583.2 V | 18 panels |
| 25 C (77 F STC) | 49.8 V | 12 panels | 597.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Exiom Solution S A EX545-144BMH-DG?
Competing CEC solar panels closest to Exiom Solution S A EX545-144BMH-DG in nameplate wattage and Voc, starting with Bluesun Solar CoLtd BSM545M10-72HBD.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar CoLtd BSM545M10-72HBD Bluesun Solar CoLtd |
545.0 W | Tie (0 W) | 49.76 V | 21.03% | 92.4% |
| Illuminate USA LLC IL5-72HBD-545M Illuminate USA LLC |
545.0 W | Tie (0 W) | 49.7 V | 21.71% | 92.1% |
| HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI HYUNDAI ENERGY SOLUTIONS CO LTD |
545.0 W | Tie (0 W) | 50.0 V | 21.21% | 94.0% |
| ASTORIOS Holding Inc ASTR144BDG-540W-US ASTORIOS Holding Inc |
540.0 W | -5.0 W | 49.8 V | 20.93% | 93.6% |
What Are the Design Limits and Best-Fit Uses for Exiom Solution S A EX545-144BMH-DG?
Evaluate Exiom Solution S A EX545-144BMH-DG (545.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Exiom Solution S A EX545-144BMH-DG reaches 55.6 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Exiom Solution S A EX545-144BMH-DG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Exiom Solution S A EX545-144BMH-DG 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,047/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bluesun Solar CoLtd BSM545M10-72HBD.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 509.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Exiom Solution S A EX545-144BMH-DG by Exiom Solution S A grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Exiom Solution S A EX545-144BMH-DG?
Multiplying Exiom Solution S A EX545-144BMH-DG's 13.92 A short-circuit current by 1.56 equals 21.72 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Exiom Solution S A EX545-144BMH-DG pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.31 V cold Voc at 14 F and handles 13.92 A Isc; string inverters cap Exiom Solution S A EX545-144BMH-DG at 11 panels on 600 V.
Is Exiom Solution S A EX545-144BMH-DG eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Exiom Solution S A EX545-144BMH-DG rely on utility bill offset (~$2,047/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)