Skip to main content
WireAndSun
Calculators
CEC PV Module

ELITE Solar ET-M672BH405GL — CEC Solar Module Specifications

Manufacturer: ELITE Solar Registry: CEC Verified Engineering Specification

ELITE Solar ET-M672BH405GL is a 405.0 W STC (377.6 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 19.85% efficiency, 49.8 V Voc at 25 C, and 55.03 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
377.6 W
Voc @ 25C
49.8 V
Efficiency
19.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ELITE Solar ET-M672BH405GL Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for ELITE Solar ET-M672BH405GL (Mono-c-Si) residential solar systems.

ELITE Solar ET-M672BH405GL delivers 198.5 W/m2 (0.06 percentage points below 19.91% CEC median) and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (439 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 56.52 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Boviet Solar Technology Co Ltd BVM6612M-405L-H (405.0 W).

Where Does ELITE Solar ET-M672BH405GL Fall Across Listed CEC Models?

Comparison of ELITE Solar ET-M672BH405GL (405.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ELITE Solar ET-M672BH405GL (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCELITE Solar ET-M67: 405.0 W

What Dataset Percentiles Define ELITE Solar ET-M672BH405GL?

Relative ranking of ELITE Solar ET-M672BH405GL across nameplate watts, 93.2% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

ELITE Solar ET-M672BH405GL Engineering BenchmarksPercentile comparison of ELITE Solar ET-M672BH405GL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.2%Module Efficiency19.85%

What Do the Dataset Ranks Show for ELITE Solar ET-M672BH405GL?

Summary of ELITE Solar ET-M672BH405GL output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,028

19.85% Aperture Efficiency

Power density 198.5 W/m2 (0.06 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.03 V at -10 C (550.3 V string) and 56.52 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 40.8 m2 (439 sq ft) producing 7,552 W PTC; NEC 690.8 OCPD floor is 16.29 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.8 * (1 + (-0.3/100) * (-10 - 25)) = 55.03 V | OCPD = 1.56 * 10.44 = 16.29 A

Inputs from CEC Modules.csv for ELITE Solar ET-M672BH405GL: Voc=49.8 V, beta_Voc=-0.3%/C, Isc=10.44 A, STC=405.0 W, Area=2.04 m2.

Result: 10 panels max on 600 V (550.3 V); 20 panels for 8 kW (439 sq ft).

What Are the Published CEC Specifications for ELITE Solar ET-M672BH405GL?

Complete CEC test sheet for ELITE Solar ET-M672BH405GL including Isc (10.44 A), Voc (49.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for ELITE Solar ET-M672BH405GL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 377.6 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.44 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.1 V / 9.62 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.85% (2.04 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many ELITE Solar ET-M672BH405GL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using ELITE Solar ET-M672BH405GL.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 329 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 439 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 549 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This ELITE Solar Series?

Related ELITE Solar power steps and black/silver trims consolidated into this ELITE Solar ET-M672BH405GL series guide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the ELITE Solar ET-M672BH405GL wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
ELITE Solar ET-M672BH400GL 400.0 W 372.9 W 49.7 V 41.7 V 19.61%
ELITE Solar ET-M672BH405GL 405.0 W 377.6 W 49.8 V 42.1 V 19.85%
ELITE Solar ET-M672BH410GL 410.0 W 382.4 W 49.9 V 42.5 V 20.1%

How Many ELITE Solar ET-M672BH405GL Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for ELITE Solar ET-M672BH405GL (49.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.8V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.52 V 10 panels 565.2 V 17 panels
-10 C (14 F) 55.03 V 10 panels 550.3 V 18 panels
0 C (32 F) 53.53 V 11 panels 588.8 V 18 panels
25 C (77 F STC) 49.8 V 12 panels 597.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to ELITE Solar ET-M672BH405GL?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6612M-405L-H (405.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.95% 93.6%
CSI Solar Co Ltd CS3U-405MS
CSI Solar Co Ltd
405.0 W Tie (0 W) 49.3 V 21.09% 93.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
405.0 W Tie (0 W) 49.2 V 21.2% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ELITE Solar ET-M672BH405GL?

Evaluate ELITE Solar ET-M672BH405GL (405.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ELITE Solar ET-M672BH405GL reaches 56.52 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (439 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of ELITE Solar ET-M672BH405GL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ELITE Solar ET-M672BH405GL 8 kW Residential Fit

Needs 20 modules (439 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 377.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ELITE Solar ET-M672BH405GL by ELITE Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many ELITE Solar ET-M672BH405GL panels fit on a 600 V winter solar string?

At -10 C (14 F), ELITE Solar ET-M672BH405GL cold Voc rises from 49.8 V to 55.03 V (beta_Voc -0.3%/C), capping a 600 V string at 10 panels (550.3 V).

How much roof area does an 8 kW array of ELITE Solar ET-M672BH405GL need?

An 8 kW DC system uses 20 ELITE Solar ET-M672BH405GL modules (8,100 W STC / 7,552 W PTC), covering roughly 439 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does ELITE Solar ET-M672BH405GL compare against Boviet Solar Technology Co Ltd BVM6612M-405L-H?

ELITE Solar ET-M672BH405GL outputs 405.0 W STC (49.8 V Voc, rank #8,961 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-405L-H delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.