Skip to main content
WireAndSun
Calculators
CEC PV Module

Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 — CEC Solar Module Specifications

Manufacturer: Elin Energy (Sirius PV) Registry: CEC Verified Engineering Specification

Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 is a 510.0 W STC (481.8 W PTC) Mono-c-Si solar module ranking #4,386 of 21,677 CEC listings (top 20.5%; higher than 79.5% of peers). It delivers 21.65% efficiency, 46.05 V Voc at 25 C, and 49.95 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
510.0 W
PTC Wattage
481.8 W
Voc @ 25C
46.05 V
Efficiency
21.65%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 Compare Against Peer CEC Listings?

Solar engineering breakdown for Elin Energy (Sirius PV) ELNSM66M-HC-BF-510: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 510.0 W STC and 481.8 W PTC, Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 sits +125.0 W vs all-CEC median (top 20.5%; higher than 79.5% of peers) among 21,677 listed modules. Power density reaches 216.6 W/m2 (1.74 percentage points above 19.91% CEC median). Mid-range 46.05 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer Hyperion Solar HY-DH132P8-505 rates 505.0 W.

Where Does Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 Fall Across Listed CEC Models?

Distribution marker showing Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 (510.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 (510.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCElin Energy (Siriu: 510.0 W

What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM66M-HC-BF-510?

Dataset percentiles tracking Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 Engineering BenchmarksPercentile comparison of Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage510.0 WPTC/STC Retention94.5%Module Efficiency21.65%

What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM66M-HC-BF-510?

Benchmark highlights for Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,386 / 21,677

Top 20.5% STC Output

510.0 W STC (+125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,009

21.65% Aperture Efficiency

Power density 216.6 W/m2 (1.74 percentage points above 19.91% CEC median). PTC/STC ratio: 94.5% (rank #2,573).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.95 V at -10 C (599.4 V string) and 51.06 V at -20 C (11 max).

8 kW Reference Array

16 Panels = 8,160 W STC

Occupies 37.7 m2 (406 sq ft) producing 7,709 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.05 * (1 + (-0.242/100) * (-10 - 25)) = 49.95 V | OCPD = 1.56 * 14.0 = 21.84 A

Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM66M-HC-BF-510: Voc=46.05 V, beta_Voc=-0.242%/C, Isc=14.0 A, STC=510.0 W, Area=2.355 m2.

Result: 12 panels max on 600 V (599.4 V); 16 panels for 8 kW (406 sq ft).

What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM66M-HC-BF-510?

Official CEC datasheet figures for Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Elin Energy (Sirius PV) ELNSM66M-HC-BF-510.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 510.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 481.8 W (94.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.05 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.87 V / 13.47 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.242 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.65% (2.355 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.12 kW 304 sq ft $1,532 $2,590
8 kW Class 16 8.16 kW 406 sq ft $2,042 $3,454
10 kW Class 20 10.2 kW 507 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Elin Energy (Sirius PV) Series?

Consolidated Elin Energy (Sirius PV) wattage variants sharing the Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 mechanical and cell layout.

Sibling CEC listings grouped into the Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Elin Energy (Sirius PV) ELNSM66M-HC-BF-500 500.0 W 472.1 W 45.65 V 37.55 V 21.23%
Elin Energy (Sirius PV) ELNSM66M-HC-BF-505 505.0 W 477.0 W 45.85 V 37.71 V 21.44%
Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 510.0 W 481.8 W 46.05 V 37.87 V 21.65%
Elin Energy (Sirius PV) ELNSM66M-HC-BF-515 515.0 W 486.6 W 46.25 V 38.03 V 21.87%
Elin Energy (Sirius PV) ELNSM66M-HC-BF-520 520.0 W 491.5 W 46.45 V 38.19 V 22.08%

How Many Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 (49.95 V at 14 F).

Computed from Voc=46.05V and beta_Voc=-0.242%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.06 V 11 panels 561.7 V 19 panels
-10 C (14 F) 49.95 V 12 panels 599.4 V 20 panels
0 C (32 F) 48.84 V 12 panels 586.1 V 20 panels
25 C (77 F STC) 46.05 V 13 panels 598.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM66M-HC-BF-510?

Competing CEC solar panels closest to Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 in nameplate wattage and Voc, starting with Hyperion Solar HY-DH132P8-505.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hyperion Solar HY-DH132P8-505
Hyperion Solar
505.0 W -5.0 W 45.72 V 21.31% 93.0%
Hyperion Solar HY-DH132P8-505-B
Hyperion Solar
505.0 W -5.0 W 45.72 V 21.31% 93.0%
Hyperion Solar HY-DH132P8-505-T
Hyperion Solar
505.0 W -5.0 W 45.72 V 21.31% 93.0%
Aptos Solar Technology LLC DNA-132-BF10-500W
Aptos Solar Technology LLC
500.0 W -10.0 W 45.6 V 21.1% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM66M-HC-BF-510?

Evaluate Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 (510.0 W STC, 46.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 reaches 51.06 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 406 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (406 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 8 kW Residential Fit

Needs 16 modules (406 sq ft) with a 25 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Hyperion Solar HY-DH132P8-505.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 481.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.

How many Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 panels fit on a 600 V winter solar string?

At -10 C (14 F), Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 cold Voc rises from 46.05 V to 49.95 V (beta_Voc -0.242%/C), capping a 600 V string at 12 panels (599.4 V).

How much roof area does an 8 kW array of Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 need?

An 8 kW DC system uses 16 Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 modules (8,160 W STC / 7,709 W PTC), covering roughly 406 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 compare against Hyperion Solar HY-DH132P8-505?

Elin Energy (Sirius PV) ELNSM66M-HC-BF-510 outputs 510.0 W STC (46.05 V Voc, rank #4,386 of 21,677), while Hyperion Solar HY-DH132P8-505 delivers 505.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.