Elin Energy (Sirius PV) ELNSM66M-HC-525 — CEC Solar Module Specifications

Manufacturer: Elin Energy (Sirius PV) Registry: CEC Verified Engineering Specification

Elin Energy (Sirius PV) ELNSM66M-HC-525 is a 525.0 W STC (495.7 W PTC) Mono-c-Si solar module ranking #4,047 of 21,677 CEC listings (top 19.4%; higher than 80.6% of peers). It delivers 22.25% efficiency, 46.65 V Voc at 25 C, and 50.47 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
525.0 W
PTC Wattage
495.7 W
Voc @ 25C
46.65 V
Efficiency
22.25%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Elin Energy (Sirius PV) ELNSM66M-HC-525 Compare Against Peer CEC Listings?

Engineering position of Elin Energy (Sirius PV) ELNSM66M-HC-525 (525.0 W STC) vs. Aptos Solar Technology LLC DNA-132-BFN10-530W-DG across 5,889 CEC Mono-c-Si solar modules.

Built with 66 Mono-c-Si cells, Elin Energy (Sirius PV) ELNSM66M-HC-525 pairs strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677) with 46.65 V nominal Voc. An 8 kW residential build (8,400 W DC, 7,931 W PTC) saves ~$2,102/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Aptos Solar Technology LLC DNA-132-BFN10-530W-DG offers a 530.0 W alternative.

Where Does Elin Energy (Sirius PV) ELNSM66M-HC-525 Fall Across Listed CEC Models?

Plots Elin Energy (Sirius PV) ELNSM66M-HC-525 at 525.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Elin Energy (Sirius PV) ELNSM66M-HC-525 (525.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCElin Energy (Siriu: 525.0 W

What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM66M-HC-525?

Benchmarks Elin Energy (Sirius PV) ELNSM66M-HC-525 on STC wattage, thermal PTC/STC retention, and 22.25 aperture conversion efficiency against CEC peers.

Elin Energy (Sirius PV) ELNSM66M-HC-525 Engineering BenchmarksPercentile comparison of Elin Energy (Sirius PV) ELNSM66M-HC-525 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage525.0 WPTC/STC Retention94.4%Module Efficiency22.25%

What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM66M-HC-525?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Elin Energy (Sirius PV) ELNSM66M-HC-525 by Elin Energy (Sirius PV).

Rank #4,047 / 21,677

Top 19.4% STC Output

525.0 W STC (+140.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,562

22.25% Aperture Efficiency

Power density 222.5 W/m2 (2.34 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.47 V at -10 C (555.2 V string) and 51.56 V at -20 C (11 max).

8 kW Reference Array

16 Panels = 8,400 W STC

Occupies 37.8 m2 (406 sq ft) producing 7,931 W PTC; NEC 690.8 OCPD floor is 22.07 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.65 * (1 + (-0.234/100) * (-10 - 25)) = 50.47 V | OCPD = 1.56 * 14.15 = 22.07 A

Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM66M-HC-525: Voc=46.65 V, beta_Voc=-0.234%/C, Isc=14.15 A, STC=525.0 W, Area=2.36 m2.

Result: 11 panels max on 600 V (555.2 V); 16 panels for 8 kW (406 sq ft).

What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM66M-HC-525?

Laboratory test ratings recorded for Elin Energy (Sirius PV) ELNSM66M-HC-525 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Elin Energy (Sirius PV) ELNSM66M-HC-525.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 525.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 495.7 W (94.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.65 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.15 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.35 V / 13.71 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.234 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.25% (2.36 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many Elin Energy (Sirius PV) ELNSM66M-HC-525 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (406 sq ft at 8 kW), and estimated Year-1 electric bill offset for Elin Energy (Sirius PV) ELNSM66M-HC-525.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.3 kW 305 sq ft $1,577 $2,666
8 kW Class 16 8.4 kW 406 sq ft $2,102 $3,555
10 kW Class 20 10.5 kW 508 sq ft $2,628 $4,444

How Many Elin Energy (Sirius PV) ELNSM66M-HC-525 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Elin Energy (Sirius PV) ELNSM66M-HC-525 (beta_Voc -0.234%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=46.65V and beta_Voc=-0.234%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.56 V 11 panels 567.2 V 19 panels
-10 C (14 F) 50.47 V 11 panels 555.2 V 19 panels
0 C (32 F) 49.38 V 12 panels 592.6 V 20 panels
25 C (77 F STC) 46.65 V 12 panels 559.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM66M-HC-525?

Closest cross-brand CEC competitors to Elin Energy (Sirius PV) ELNSM66M-HC-525 matched near 525.0 W STC and 46.65 V Voc, led by Aptos Solar Technology LLC DNA-132-BFN10-530W-DG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-132-BFN10-530W-DG
Aptos Solar Technology LLC
530.0 W +5.0 W 46.72 V 22.36% 94.9%
Aptos Solar Technology LLC DNA-132-BFN10-520W-DG
Aptos Solar Technology LLC
520.0 W -5.0 W 46.44 V 21.94% 94.9%
Auxin Solar AXN10M525W
Auxin Solar
525.0 W Tie (0 W) 44.49 V 24.42% 92.0%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
520.0 W -5.0 W 48.33 V 27.37% 95.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM66M-HC-525?

Evaluate Elin Energy (Sirius PV) ELNSM66M-HC-525 (525.0 W STC, 46.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM66M-HC-525 reaches 51.56 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 406 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM66M-HC-525 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Elin Energy (Sirius PV) ELNSM66M-HC-525 8 kW Residential Fit

Needs 16 modules (406 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Aptos Solar Technology LLC DNA-132-BFN10-530W-DG.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 495.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Elin Energy (Sirius PV) ELNSM66M-HC-525 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Elin Energy (Sirius PV) ELNSM66M-HC-525?

Multiplying Elin Energy (Sirius PV) ELNSM66M-HC-525's 14.15 A short-circuit current by 1.56 equals 22.07 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Elin Energy (Sirius PV) ELNSM66M-HC-525 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.47 V cold Voc at 14 F and handles 14.15 A Isc; string inverters cap Elin Energy (Sirius PV) ELNSM66M-HC-525 at 11 panels on 600 V.

Is Elin Energy (Sirius PV) ELNSM66M-HC-525 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Elin Energy (Sirius PV) ELNSM66M-HC-525 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.