Manufacturer: Elin Energy (Sirius PV) Registry: CEC Verified Engineering Specification

Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 is a 460.0 W STC (438.1 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 23.71% efficiency, 40.1 V Voc at 25 C, and 43.43 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
460.0 W
PTC Wattage
438.1 W
Voc @ 25C
40.1 V
Efficiency
23.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 Compare Against Peer CEC Listings?

How Elin Energy (Sirius PV) Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 handles rooftop heat (438.1 W PTC), 8 kW sizing, and cold winter string voltage.

Elin Energy (Sirius PV) builds the Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 237.1 W/m2 (3.80 percentage points above 19.91% CEC median). Compared against Auxin Solar AXN10M460W (460.0 W), this model holds strong 95.2% PTC-to-STC heat retention (#399 of 21,677). Mid-range 40.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.82 A overcurrent floor served by a 25 A breaker.

Where Does Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 Fall Across Listed CEC Models?

Where Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 (460.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 (460.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCElin Energy (Siriu: 460.0 W

What Dataset Percentiles Define Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460?

Percentile placement of Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 across power density (237.1 W/m2), thermal retention, and nameplate STC wattage.

Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 Engineering BenchmarksPercentile comparison of Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage460.0 WPTC/STC Retention95.2%Module Efficiency23.71%

What Do the Dataset Ranks Show for Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460?

Four critical engineering numbers homeowners and solar installers check first when reviewing Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 specifications.

Rank #5,199 / 21,677

Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #339

23.71% Aperture Efficiency

Power density 237.1 W/m2 (3.80 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.43 V at -10 C (564.6 V string) and 44.38 V at -20 C (13 max).

8 kW Reference Array

18 Panels = 8,280 W STC

Occupies 34.9 m2 (376 sq ft) producing 7,886 W PTC; NEC 690.8 OCPD floor is 21.82 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.1 * (1 + (-0.237/100) * (-10 - 25)) = 43.43 V | OCPD = 1.56 * 13.99 = 21.82 A

Inputs from CEC Modules.csv for Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460: Voc=40.1 V, beta_Voc=-0.237%/C, Isc=13.99 A, STC=460.0 W, Area=1.94 m2.

Result: 13 panels max on 600 V (564.6 V); 18 panels for 8 kW (376 sq ft).

What Are the Published CEC Specifications for Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460.

Official California Energy Commission (NREL SAM) test parameters for Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 460.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 438.1 W (95.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.99 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.5 V / 13.34 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.237 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.71% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 (460.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.44 kW 292 sq ft $1,612 $2,726
8 kW Class 18 8.28 kW 376 sq ft $2,072 $3,504
10 kW Class 22 10.12 kW 459 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Elin Energy (Sirius PV) Series?

All closely matched Elin Energy (Sirius PV) wattages and cosmetic trims sharing the Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 architecture.

Sibling CEC listings grouped into the Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-450 450.0 W 428.4 W 39.7 V 34.18 V 23.2%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-455 455.0 W 433.2 W 39.9 V 34.34 V 23.45%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 460.0 W 438.1 W 40.1 V 34.5 V 23.71%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-465 465.0 W 443.0 W 40.3 V 34.65 V 23.97%

How Many Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 Modules Fit in a Cold-Weather String?

Maximum series module counts for Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.1V and beta_Voc=-0.237%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.38 V 13 panels 576.9 V 22 panels
-10 C (14 F) 43.43 V 13 panels 564.6 V 23 panels
0 C (32 F) 42.48 V 14 panels 594.7 V 23 panels
25 C (77 F STC) 40.1 V 14 panels 561.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460?

Alternative CEC solar modules from competing brands near Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 (460.0 W), including Auxin Solar AXN10M460W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN10M460W
Auxin Solar
460.0 W Tie (0 W) 39.88 V 23.71% 92.0%
CSI Solar Co Ltd CS61-54TM-460H
CSI Solar Co Ltd
460.0 W Tie (0 W) 39.3 V 23.23% 94.8%
AEG SOLAR ENERGY SRL ALPS54D30-455/TP
AEG SOLAR ENERGY SRL
455.0 W -5.0 W 40.1 V 22.86% 94.4%
Aptos Solar Technology LLC DNA-120-BF10-460W
Aptos Solar Technology LLC
460.0 W Tie (0 W) 41.5 V 21.3% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460?

Evaluate Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 (460.0 W STC, 40.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 reaches 44.38 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 8 kW Residential Fit

Needs 18 modules (376 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN10M460W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 438.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 by Elin Energy (Sirius PV) grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460?

Multiplying Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460's 13.99 A short-circuit current by 1.56 equals 21.82 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.43 V cold Voc at 14 F and handles 13.99 A Isc; string inverters cap Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 at 13 panels on 600 V.

Is Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460 rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.