CSI Solar Co Ltd CS7L-605MB-AG is a 605.0 W STC (568.9 W PTC) Mono-c-Si solar module ranking #1,214 of 21,677 CEC listings (top 6.1%; higher than 93.9% of peers). It delivers 28.27% efficiency, 41.5 V Voc at 25 C, and 45.74 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 605.0 W
- PTC Wattage
- 568.9 W
- Voc @ 25C
- 41.5 V
- Efficiency
- 28.27%
How Does CSI Solar Co Ltd CS7L-605MB-AG Compare Against Peer CEC Listings?
Solar engineering breakdown for CSI Solar Co Ltd CS7L-605MB-AG: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from CSI Solar Co Ltd and peers, CSI Solar Co Ltd CS7L-605MB-AG stands 195.0 W above the 410.0 W Mono-c-Si median and strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677). Sizing 6 kW (10 panels) to 10 kW (17 panels) yields $1,514-$2,575/yr in baseline US bill offset. Mid-range 41.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does CSI Solar Co Ltd CS7L-605MB-AG Fall Across Listed CEC Models?
Distribution marker showing CSI Solar Co Ltd CS7L-605MB-AG (605.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CSI Solar Co Ltd CS7L-605MB-AG?
Dataset percentiles tracking CSI Solar Co Ltd CS7L-605MB-AG power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS7L-605MB-AG?
Benchmark highlights for CSI Solar Co Ltd CS7L-605MB-AG covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 6.1% STC Output
605.0 W STC (+220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
28.27% Aperture Efficiency
Power density 282.7 W/m2 (8.36 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.74 V at -10 C (594.6 V string) and 46.95 V at -20 C (12 max).
14 Panels = 8,470 W STC
Occupies 30.0 m2 (322 sq ft) producing 7,965 W PTC; NEC 690.8 OCPD floor is 28.89 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.5 * (1 + (-0.292/100) * (-10 - 25)) = 45.74 V | OCPD = 1.56 * 18.52 = 28.89 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS7L-605MB-AG: Voc=41.5 V, beta_Voc=-0.292%/C, Isc=18.52 A, STC=605.0 W, Area=2.14 m2.
Result: 13 panels max on 600 V (594.6 V); 14 panels for 8 kW (322 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS7L-605MB-AG?
Official CEC datasheet figures for CSI Solar Co Ltd CS7L-605MB-AG (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 605.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 568.9 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.52 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.1 V / 17.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.292 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 28.27% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many CSI Solar Co Ltd CS7L-605MB-AG Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CSI Solar Co Ltd CS7L-605MB-AG modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.05 kW | 230 sq ft | $1,514 | $2,561 |
| 8 kW Class | 14 | 8.47 kW | 322 sq ft | $2,120 | $3,585 |
| 10 kW Class | 17 | 10.29 kW | 392 sq ft | $2,575 | $4,355 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Consolidated CSI Solar Co Ltd wattage variants sharing the CSI Solar Co Ltd CS7L-605MB-AG mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS7L-600MB-AG | 600.0 W | 564.0 W | 41.3 V | 34.9 V | 28.04% |
| CSI Solar Co Ltd CS7L-605MB-AG | 605.0 W | 568.9 W | 41.5 V | 35.1 V | 28.27% |
| CSI Solar Co Ltd CS7L-610MB-AG | 610.0 W | 573.7 W | 41.7 V | 35.3 V | 28.5% |
How Many CSI Solar Co Ltd CS7L-605MB-AG Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS7L-605MB-AG (45.74 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.95 V | 12 panels | 563.4 V | 21 panels |
| -10 C (14 F) | 45.74 V | 13 panels | 594.6 V | 21 panels |
| 0 C (32 F) | 44.53 V | 13 panels | 578.9 V | 22 panels |
| 25 C (77 F STC) | 41.5 V | 14 panels | 581.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS7L-605MB-AG?
Competing CEC solar panels closest to CSI Solar Co Ltd CS7L-605MB-AG in nameplate wattage and Voc, starting with JA Solar JAM66D45-610/LB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| JA Solar JAM66D45-610/LB JA Solar |
610.0 W | +5.0 W | 48.1 V | 23.11% | 93.9% |
| Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF Boviet Solar Technology Co Ltd |
610.0 W | +5.0 W | 48.25 V | 24.21% | 95.3% |
| Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF-DG Boviet Solar Technology Co Ltd |
610.0 W | +5.0 W | 48.25 V | 24.21% | 95.3% |
| Jinko Solar Co Ltd JKM610N-66HL4M-BDV Jinko Solar Co Ltd |
610.0 W | +5.0 W | 48.68 V | 22.59% | 94.2% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS7L-605MB-AG?
Evaluate CSI Solar Co Ltd CS7L-605MB-AG (605.0 W STC, 41.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS7L-605MB-AG reaches 46.95 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 322 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS7L-605MB-AG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS7L-605MB-AG 8 kW Residential Fit
Needs 14 modules (322 sq ft) with a 30 A string OCPD, offsetting ~$2,120/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare JA Solar JAM66D45-610/LB.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 568.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS7L-605MB-AG by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS7L-605MB-AG?
Multiplying CSI Solar Co Ltd CS7L-605MB-AG's 18.52 A short-circuit current by 1.56 equals 28.89 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can CSI Solar Co Ltd CS7L-605MB-AG pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.74 V cold Voc at 14 F and handles 18.52 A Isc; string inverters cap CSI Solar Co Ltd CS7L-605MB-AG at 13 panels on 600 V.
Is CSI Solar Co Ltd CS7L-605MB-AG eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS7L-605MB-AG rely on utility bill offset (~$2,120/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)