CertainTeed Apollo Tile II - 75x is a 75.0 W STC (65.5 W PTC) Mono-c-Si solar module ranking #21,614 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 13.89% efficiency, 9.92 V Voc at 25 C, and 10.87 V cold Voc at -10 C (55 panels max per 600 V string).
- STC Wattage
- 75.0 W
- PTC Wattage
- 65.5 W
- Voc @ 25C
- 9.92 V
- Efficiency
- 13.89%
How Does CertainTeed Apollo Tile II - 75x Compare Against Peer CEC Listings?
Solar engineering breakdown for CertainTeed Apollo Tile II - 75x: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from CertainTeed and peers, CertainTeed Apollo Tile II - 75x stands 335.0 W below the 410.0 W Mono-c-Si median and typical 87.3% PTC-to-STC thermal output (65.5 W real-world rating). Sizing 6 kW (80 panels) to 10 kW (134 panels) yields $1,502-$2,515/yr in baseline US bill offset. Lower 9.92 V string voltage fits 55 panels in series at 14 F and pairs easily with microinverters.
Where Does CertainTeed Apollo Tile II - 75x Fall Across Listed CEC Models?
Distribution marker showing CertainTeed Apollo Tile II - 75x (75.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CertainTeed Apollo Tile II - 75x?
Dataset percentiles tracking CertainTeed Apollo Tile II - 75x power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CertainTeed Apollo Tile II - 75x?
Benchmark highlights for CertainTeed Apollo Tile II - 75x covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
75.0 W STC · Higher Than 0.3%
75.0 W STC (-310.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
13.89% Aperture Efficiency
Power density 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). PTC/STC ratio: 87.3% (rank #21,570).
55 Panels Max @ -10 C (600 V)
Cold Voc reaches 10.87 V at -10 C (597.8 V string) and 11.14 V at -20 C (53 max).
107 Panels = 8,025 W STC
Occupies 57.8 m2 (622 sq ft) producing 7,008 W PTC; NEC 690.8 OCPD floor is 15.01 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 9.92 * (1 + (-0.273/100) * (-10 - 25)) = 10.87 V | OCPD = 1.56 * 9.62 = 15.01 A
Inputs from CEC Modules.csv for CertainTeed Apollo Tile II - 75x: Voc=9.92 V, beta_Voc=-0.273%/C, Isc=9.62 A, STC=75.0 W, Area=0.54 m2.
Result: 55 panels max on 600 V (597.8 V); 107 panels for 8 kW (622 sq ft).
What Are the Published CEC Specifications for CertainTeed Apollo Tile II - 75x?
Official CEC datasheet figures for CertainTeed Apollo Tile II - 75x (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 75.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 65.5 W (87.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 9.92 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 8.06 V / 9.33 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.273 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.89% (0.54 m2) | Array roof footprint density |
| Cell Count & Technology | 14 cells (Mono-c-Si) | Monofacial backsheet |
How Many CertainTeed Apollo Tile II - 75x Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CertainTeed Apollo Tile II - 75x modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 80 | 6.0 kW | 465 sq ft | $1,502 | $2,539 |
| 8 kW Class | 107 | 8.03 kW | 622 sq ft | $2,010 | $3,398 |
| 10 kW Class | 134 | 10.05 kW | 779 sq ft | $2,515 | $4,253 |
How Many CertainTeed Apollo Tile II - 75x Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CertainTeed Apollo Tile II - 75x (10.87 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 11.14 V | 53 panels | 590.4 V | 89 panels |
| -10 C (14 F) | 10.87 V | 55 panels | 597.8 V | 91 panels |
| 0 C (32 F) | 10.6 V | 56 panels | 593.6 V | 94 panels |
| 25 C (77 F STC) | 9.92 V | 60 panels | 595.2 V | 100 panels |
Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo Tile II - 75x?
Competing CEC solar panels closest to CertainTeed Apollo Tile II - 75x in nameplate wattage and Voc, starting with Merlin Solar Technologies Inc Solstice Shingle 72W-01.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc Solstice Shingle 72W-01 Merlin Solar Technologies Inc |
72.0 W | -3.0 W | 9.65 V | 13.58% | 89.4% |
| Merlin Solar Technologies Inc Solstice Shingle 70W-01 Merlin Solar Technologies Inc |
70.0 W | -5.0 W | 9.51 V | 13.21% | 89.4% |
| LUMA Resources LRSS LUMA Resources |
80.0 W | +5.0 W | 10.43 V | 16.0% | 90.0% |
| Arka Energy Inc AEP-821-00012-A Arka Energy Inc |
77.0 W | +2.0 W | 11.56 V | 14.81% | 92.1% |
What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo Tile II - 75x?
Evaluate CertainTeed Apollo Tile II - 75x (75.0 W STC, 9.92 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo Tile II - 75x reaches 11.14 V per panel—exceeding 53 panels in series voids 600 V inverter warranties.
- Footprint constraint: 107 panels for an 8 kW build require 622 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 107 panels (622 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed Apollo Tile II - 75x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CertainTeed Apollo Tile II - 75x 8 kW Residential Fit
Needs 107 modules (622 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 55 panels (-10 C) or 53 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 72W-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 65.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CertainTeed Apollo Tile II - 75x by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for CertainTeed Apollo Tile II - 75x?
Multiplying CertainTeed Apollo Tile II - 75x's 9.62 A short-circuit current by 1.56 equals 15.01 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can CertainTeed Apollo Tile II - 75x pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 10.87 V cold Voc at 14 F and handles 9.62 A Isc; string inverters cap CertainTeed Apollo Tile II - 75x at 55 panels on 600 V.
Is CertainTeed Apollo Tile II - 75x eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CertainTeed Apollo Tile II - 75x rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)