CertainTeed Apollo Tile II - 74x is a 74.0 W STC (64.6 W PTC) Mono-c-Si solar module ranking #21,621 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 13.7% efficiency, 9.86 V Voc at 25 C, and 10.8 V cold Voc at -10 C (55 panels max per 600 V string).

STC Wattage
74.0 W
PTC Wattage
64.6 W
Voc @ 25C
9.86 V
Efficiency
13.7%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CertainTeed Apollo Tile II - 74x Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CertainTeed Apollo Tile II - 74x (Mono-c-Si) residential solar systems.

CertainTeed Apollo Tile II - 74x delivers 137.0 W/m2 (6.21 percentage points below 19.91% CEC median) and typical 87.3% PTC-to-STC thermal output (64.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 109 panels (634 sq ft). At -4 F (-20 C), string voltage climbs to 11.07 V per unit, capping 600 V circuits at 54 panels. Compare specs directly with Merlin Solar Technologies Inc Solstice Shingle 72W-01 (72.0 W).

Where Does CertainTeed Apollo Tile II - 74x Fall Across Listed CEC Models?

Comparison of CertainTeed Apollo Tile II - 74x (74.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CertainTeed Apollo Tile II - 74x (74.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCertainTeed Apollo: 74.0 W

What Dataset Percentiles Define CertainTeed Apollo Tile II - 74x?

Relative ranking of CertainTeed Apollo Tile II - 74x across nameplate watts, 87.3% PTC thermal ratio, and module aperture efficiency.

CertainTeed Apollo Tile II - 74x Engineering BenchmarksPercentile comparison of CertainTeed Apollo Tile II - 74x wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage74.0 WPTC/STC Retention87.3%Module Efficiency13.7%

What Do the Dataset Ranks Show for CertainTeed Apollo Tile II - 74x?

Summary of CertainTeed Apollo Tile II - 74x output rank, 8 kW array size (109 panels), efficiency rating, and 600 V string limit.

Rank #21,621 / 21,677

74.0 W STC · Higher Than 0.3%

74.0 W STC (-311.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,108

13.7% Aperture Efficiency

Power density 137.0 W/m2 (6.21 percentage points below 19.91% CEC median). PTC/STC ratio: 87.3% (rank #21,570).

NEC 690.7 Limit

55 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.8 V at -10 C (594.0 V string) and 11.07 V at -20 C (54 max).

8 kW Reference Array

109 Panels = 8,066 W STC

Occupies 58.9 m2 (634 sq ft) producing 7,041 W PTC; NEC 690.8 OCPD floor is 14.94 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.86 * (1 + (-0.273/100) * (-10 - 25)) = 10.8 V | OCPD = 1.56 * 9.58 = 14.94 A

Inputs from CEC Modules.csv for CertainTeed Apollo Tile II - 74x: Voc=9.86 V, beta_Voc=-0.273%/C, Isc=9.58 A, STC=74.0 W, Area=0.54 m2.

Result: 55 panels max on 600 V (594.0 V); 109 panels for 8 kW (634 sq ft).

What Are the Published CEC Specifications for CertainTeed Apollo Tile II - 74x?

Complete CEC test sheet for CertainTeed Apollo Tile II - 74x including Isc (9.58 A), Voc (9.86 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed Apollo Tile II - 74x.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 74.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 64.6 W (87.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 9.86 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.58 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 8.01 V / 9.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.273 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.7% (0.54 m2) Array roof footprint density
Cell Count & Technology 14 cells (Mono-c-Si) Monofacial backsheet

How Many CertainTeed Apollo Tile II - 74x Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CertainTeed Apollo Tile II - 74x.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 82 6.07 kW 477 sq ft $1,519 $2,569
8 kW Class 109 8.07 kW 634 sq ft $2,020 $3,415
10 kW Class 136 10.06 kW 791 sq ft $2,518 $4,258

How Many CertainTeed Apollo Tile II - 74x Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for CertainTeed Apollo Tile II - 74x (9.86 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=9.86V and beta_Voc=-0.273%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 11.07 V 54 panels 597.8 V 90 panels
-10 C (14 F) 10.8 V 55 panels 594.0 V 92 panels
0 C (32 F) 10.53 V 56 panels 589.7 V 94 panels
25 C (77 F STC) 9.86 V 60 panels 591.6 V 101 panels

Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo Tile II - 74x?

Four comparable CEC modules such as Merlin Solar Technologies Inc Solstice Shingle 72W-01 (72.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Merlin Solar Technologies Inc Solstice Shingle 72W-01
Merlin Solar Technologies Inc
72.0 W -2.0 W 9.65 V 13.58% 89.4%
Merlin Solar Technologies Inc Solstice Shingle 70W-01
Merlin Solar Technologies Inc
70.0 W -4.0 W 9.51 V 13.21% 89.4%
Merlin Solar Technologies Inc Solstice Shingle 68W-01
Merlin Solar Technologies Inc
68.0 W -6.0 W 9.37 V 12.83% 89.4%
LUMA Resources LRSS
LUMA Resources
80.0 W +6.0 W 10.43 V 16.0% 90.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo Tile II - 74x?

Evaluate CertainTeed Apollo Tile II - 74x (74.0 W STC, 9.86 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo Tile II - 74x reaches 11.07 V per panel—exceeding 54 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 109 panels for an 8 kW build require 634 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 109 panels (634 sq ft).
  • 2026 tax credit baseline: cash residential installs of CertainTeed Apollo Tile II - 74x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CertainTeed Apollo Tile II - 74x 8 kW Residential Fit

Needs 109 modules (634 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 55 panels (-10 C) or 54 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 72W-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 64.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed Apollo Tile II - 74x by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.

How many CertainTeed Apollo Tile II - 74x panels fit on a 600 V winter solar string?

At -10 C (14 F), CertainTeed Apollo Tile II - 74x cold Voc rises from 9.86 V to 10.8 V (beta_Voc -0.273%/C), capping a 600 V string at 55 panels (594.0 V).

How much roof area does an 8 kW array of CertainTeed Apollo Tile II - 74x need?

An 8 kW DC system uses 109 CertainTeed Apollo Tile II - 74x modules (8,066 W STC / 7,041 W PTC), covering roughly 634 sq ft and saving ~$2,020/yr at 18.54 c/kWh.

How does CertainTeed Apollo Tile II - 74x compare against Merlin Solar Technologies Inc Solstice Shingle 72W-01?

CertainTeed Apollo Tile II - 74x outputs 74.0 W STC (9.86 V Voc, rank #21,621 of 21,677), while Merlin Solar Technologies Inc Solstice Shingle 72W-01 delivers 72.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.