Skip to main content
WireAndSun
Calculators
CEC PV Module

CertainTeed Apollo Tile II - 71x — CEC Solar Module Specifications

Manufacturer: CertainTeed Registry: CEC Verified Engineering Specification

CertainTeed Apollo Tile II - 71x is a 71.0 W STC (61.9 W PTC) Mono-c-Si solar module ranking #21,635 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 13.15% efficiency, 9.64 V Voc at 25 C, and 10.56 V cold Voc at -10 C (56 panels max per 600 V string).

STC Wattage
71.0 W
PTC Wattage
61.9 W
Voc @ 25C
9.64 V
Efficiency
13.15%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CertainTeed Apollo Tile II - 71x Compare Against Peer CEC Listings?

Solar engineering breakdown for CertainTeed Apollo Tile II - 71x: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 71.0 W STC and 61.9 W PTC, CertainTeed Apollo Tile II - 71x sits -314.0 W vs all-CEC median (below all-CEC median; higher than 0.2% of peers) among 21,677 listed modules. Power density reaches 131.5 W/m2 (6.76 percentage points below 19.91% CEC median). Lower 9.64 V string voltage fits 56 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 94 panels in series. Alternative peer Merlin Solar Technologies Inc Solstice Shingle 72W-01 rates 72.0 W.

Where Does CertainTeed Apollo Tile II - 71x Fall Across Listed CEC Models?

Distribution marker showing CertainTeed Apollo Tile II - 71x (71.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CertainTeed Apollo Tile II - 71x (71.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCertainTeed Apollo: 71.0 W

What Dataset Percentiles Define CertainTeed Apollo Tile II - 71x?

Dataset percentiles tracking CertainTeed Apollo Tile II - 71x power output, thermal retention ratio, and aperture efficiency against 21,677 models.

CertainTeed Apollo Tile II - 71x Engineering BenchmarksPercentile comparison of CertainTeed Apollo Tile II - 71x wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage71.0 WPTC/STC Retention87.2%Module Efficiency13.15%

What Do the Dataset Ranks Show for CertainTeed Apollo Tile II - 71x?

Benchmark highlights for CertainTeed Apollo Tile II - 71x covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,635 / 21,677

71.0 W STC · Higher Than 0.2%

71.0 W STC (-314.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,365

13.15% Aperture Efficiency

Power density 131.5 W/m2 (6.76 percentage points below 19.91% CEC median). PTC/STC ratio: 87.2% (rank #21,580).

NEC 690.7 Limit

56 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.56 V at -10 C (591.4 V string) and 10.82 V at -20 C (55 max).

8 kW Reference Array

113 Panels = 8,023 W STC

Occupies 61.0 m2 (657 sq ft) producing 6,995 W PTC; NEC 690.8 OCPD floor is 14.76 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.64 * (1 + (-0.273/100) * (-10 - 25)) = 10.56 V | OCPD = 1.56 * 9.46 = 14.76 A

Inputs from CEC Modules.csv for CertainTeed Apollo Tile II - 71x: Voc=9.64 V, beta_Voc=-0.273%/C, Isc=9.46 A, STC=71.0 W, Area=0.54 m2.

Result: 56 panels max on 600 V (591.4 V); 113 panels for 8 kW (657 sq ft).

What Are the Published CEC Specifications for CertainTeed Apollo Tile II - 71x?

Official CEC datasheet figures for CertainTeed Apollo Tile II - 71x (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed Apollo Tile II - 71x.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 71.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 61.9 W (87.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 9.64 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.46 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 7.82 V / 9.09 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.273 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.15% (0.54 m2) Array roof footprint density
Cell Count & Technology 14 cells (Mono-c-Si) Monofacial backsheet

How Many CertainTeed Apollo Tile II - 71x Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many CertainTeed Apollo Tile II - 71x modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 85 6.04 kW 494 sq ft $1,512 $2,556
8 kW Class 113 8.02 kW 657 sq ft $2,007 $3,394
10 kW Class 141 10.01 kW 820 sq ft $2,505 $4,236

How Many CertainTeed Apollo Tile II - 71x Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on CertainTeed Apollo Tile II - 71x (10.56 V at 14 F).

Computed from Voc=9.64V and beta_Voc=-0.273%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 10.82 V 55 panels 595.1 V 92 panels
-10 C (14 F) 10.56 V 56 panels 591.4 V 94 panels
0 C (32 F) 10.3 V 58 panels 597.4 V 97 panels
25 C (77 F STC) 9.64 V 62 panels 597.7 V 103 panels

Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo Tile II - 71x?

Competing CEC solar panels closest to CertainTeed Apollo Tile II - 71x in nameplate wattage and Voc, starting with Merlin Solar Technologies Inc Solstice Shingle 72W-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Merlin Solar Technologies Inc Solstice Shingle 72W-01
Merlin Solar Technologies Inc
72.0 W +1.0 W 9.65 V 13.58% 89.4%
Merlin Solar Technologies Inc Solstice Shingle 70W-01
Merlin Solar Technologies Inc
70.0 W -1.0 W 9.51 V 13.21% 89.4%
Merlin Solar Technologies Inc Solstice Shingle 68W-01
Merlin Solar Technologies Inc
68.0 W -3.0 W 9.37 V 12.83% 89.4%
HALEE Inc HST-61-E-FP
HALEE Inc
61.0 W -10.0 W 9.5 V 14.88% 85.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo Tile II - 71x?

Evaluate CertainTeed Apollo Tile II - 71x (71.0 W STC, 9.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo Tile II - 71x reaches 10.82 V per panel—exceeding 55 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 113 panels for an 8 kW build require 657 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 113 panels (657 sq ft).
  • 2026 tax credit baseline: cash residential installs of CertainTeed Apollo Tile II - 71x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CertainTeed Apollo Tile II - 71x 8 kW Residential Fit

Needs 113 modules (657 sq ft) with a 15 A string OCPD, offsetting ~$2,007/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 56 panels (-10 C) or 55 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 72W-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 61.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed Apollo Tile II - 71x by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.

How many CertainTeed Apollo Tile II - 71x panels fit on a 600 V winter solar string?

At -10 C (14 F), CertainTeed Apollo Tile II - 71x cold Voc rises from 9.64 V to 10.56 V (beta_Voc -0.273%/C), capping a 600 V string at 56 panels (591.4 V).

How much roof area does an 8 kW array of CertainTeed Apollo Tile II - 71x need?

An 8 kW DC system uses 113 CertainTeed Apollo Tile II - 71x modules (8,023 W STC / 6,995 W PTC), covering roughly 657 sq ft and saving ~$2,007/yr at 18.54 c/kWh.

How does CertainTeed Apollo Tile II - 71x compare against Merlin Solar Technologies Inc Solstice Shingle 72W-01?

CertainTeed Apollo Tile II - 71x outputs 71.0 W STC (9.64 V Voc, rank #21,635 of 21,677), while Merlin Solar Technologies Inc Solstice Shingle 72W-01 delivers 72.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.