CertainTeed Apollo II - 74x is a 74.0 W STC (63.3 W PTC) Mono-c-Si solar module ranking #21,621 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 13.96% efficiency, 9.86 V Voc at 25 C, and 10.8 V cold Voc at -10 C (55 panels max per 600 V string).
- STC Wattage
- 74.0 W
- PTC Wattage
- 63.3 W
- Voc @ 25C
- 9.86 V
- Efficiency
- 13.96%
How Does CertainTeed Apollo II - 74x Compare Against Peer CEC Listings?
Solar engineering breakdown for CertainTeed Apollo II - 74x: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 74.0 W STC and 63.3 W PTC, CertainTeed Apollo II - 74x sits -311.0 W vs all-CEC median (below all-CEC median; higher than 0.3% of peers) among 21,677 listed modules. Power density reaches 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). Lower 9.86 V string voltage fits 55 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 92 panels in series. Alternative peer Merlin Solar Technologies Inc Solstice Shingle 72W-01 rates 72.0 W.
Where Does CertainTeed Apollo II - 74x Fall Across Listed CEC Models?
Distribution marker showing CertainTeed Apollo II - 74x (74.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CertainTeed Apollo II - 74x?
Dataset percentiles tracking CertainTeed Apollo II - 74x power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CertainTeed Apollo II - 74x?
Benchmark highlights for CertainTeed Apollo II - 74x covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
74.0 W STC · Higher Than 0.3%
74.0 W STC (-311.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
13.96% Aperture Efficiency
Power density 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). PTC/STC ratio: 85.5% (rank #21,659).
55 Panels Max @ -10 C (600 V)
Cold Voc reaches 10.8 V at -10 C (594.0 V string) and 11.07 V at -20 C (54 max).
109 Panels = 8,066 W STC
Occupies 57.8 m2 (622 sq ft) producing 6,900 W PTC; NEC 690.8 OCPD floor is 14.94 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 9.86 * (1 + (-0.273/100) * (-10 - 25)) = 10.8 V | OCPD = 1.56 * 9.58 = 14.94 A
Inputs from CEC Modules.csv for CertainTeed Apollo II - 74x: Voc=9.86 V, beta_Voc=-0.273%/C, Isc=9.58 A, STC=74.0 W, Area=0.53 m2.
Result: 55 panels max on 600 V (594.0 V); 109 panels for 8 kW (622 sq ft).
What Are the Published CEC Specifications for CertainTeed Apollo II - 74x?
Official CEC datasheet figures for CertainTeed Apollo II - 74x (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 74.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 63.3 W (85.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 9.86 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 8.01 V / 9.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.273 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.96% (0.53 m2) | Array roof footprint density |
| Cell Count & Technology | 14 cells (Mono-c-Si) | Monofacial backsheet |
How Many CertainTeed Apollo II - 74x Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CertainTeed Apollo II - 74x modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 82 | 6.07 kW | 468 sq ft | $1,519 | $2,569 |
| 8 kW Class | 109 | 8.07 kW | 622 sq ft | $2,020 | $3,415 |
| 10 kW Class | 136 | 10.06 kW | 776 sq ft | $2,518 | $4,258 |
How Many CertainTeed Apollo II - 74x Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CertainTeed Apollo II - 74x (10.8 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 11.07 V | 54 panels | 597.8 V | 90 panels |
| -10 C (14 F) | 10.8 V | 55 panels | 594.0 V | 92 panels |
| 0 C (32 F) | 10.53 V | 56 panels | 589.7 V | 94 panels |
| 25 C (77 F STC) | 9.86 V | 60 panels | 591.6 V | 101 panels |
Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo II - 74x?
Competing CEC solar panels closest to CertainTeed Apollo II - 74x in nameplate wattage and Voc, starting with Merlin Solar Technologies Inc Solstice Shingle 72W-01.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc Solstice Shingle 72W-01 Merlin Solar Technologies Inc |
72.0 W | -2.0 W | 9.65 V | 13.58% | 89.4% |
| Merlin Solar Technologies Inc Solstice Shingle 70W-01 Merlin Solar Technologies Inc |
70.0 W | -4.0 W | 9.51 V | 13.21% | 89.4% |
| Merlin Solar Technologies Inc Solstice Shingle 68W-01 Merlin Solar Technologies Inc |
68.0 W | -6.0 W | 9.37 V | 12.83% | 89.4% |
| LUMA Resources LRSS LUMA Resources |
80.0 W | +6.0 W | 10.43 V | 16.0% | 90.0% |
What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo II - 74x?
Evaluate CertainTeed Apollo II - 74x (74.0 W STC, 9.86 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo II - 74x reaches 11.07 V per panel—exceeding 54 panels in series voids 600 V inverter warranties.
- Footprint constraint: 109 panels for an 8 kW build require 622 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 109 panels (622 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed Apollo II - 74x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CertainTeed Apollo II - 74x 8 kW Residential Fit
Needs 109 modules (622 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 55 panels (-10 C) or 54 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 72W-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 63.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CertainTeed Apollo II - 74x by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.
How many CertainTeed Apollo II - 74x panels fit on a 600 V winter solar string?
At -10 C (14 F), CertainTeed Apollo II - 74x cold Voc rises from 9.86 V to 10.8 V (beta_Voc -0.273%/C), capping a 600 V string at 55 panels (594.0 V).
How much roof area does an 8 kW array of CertainTeed Apollo II - 74x need?
An 8 kW DC system uses 109 CertainTeed Apollo II - 74x modules (8,066 W STC / 6,900 W PTC), covering roughly 622 sq ft and saving ~$2,020/yr at 18.54 c/kWh.
How does CertainTeed Apollo II - 74x compare against Merlin Solar Technologies Inc Solstice Shingle 72W-01?
CertainTeed Apollo II - 74x outputs 74.0 W STC (9.86 V Voc, rank #21,621 of 21,677), while Merlin Solar Technologies Inc Solstice Shingle 72W-01 delivers 72.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)