Skip to main content
WireAndSun
Calculators
CEC PV Module

CertainTeed Apollo II - 67 — CEC Solar Module Specifications

Manufacturer: CertainTeed Registry: CEC Verified Engineering Specification

CertainTeed Apollo II - 67 is a 67.0 W STC (60.9 W PTC) Mono-c-Si solar module ranking #21,647 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 15.95% efficiency, 9.35 V Voc at 25 C, and 10.25 V cold Voc at -10 C (58 panels max per 600 V string).

STC Wattage
67.0 W
PTC Wattage
60.9 W
Voc @ 25C
9.35 V
Efficiency
15.95%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CertainTeed Apollo II - 67 Compare Against Peer CEC Listings?

How CertainTeed CertainTeed Apollo II - 67 handles rooftop heat (60.9 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, CertainTeed Apollo II - 67 exhibits 9.34 A short-circuit current, requiring a 14.57 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,647 of 21,677 (343.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 50.4 m2 for an 8 kW system (150 panels for 10 kW). Lower 9.35 V string voltage fits 58 panels in series at 14 F and pairs easily with microinverters.

Where Does CertainTeed Apollo II - 67 Fall Across Listed CEC Models?

Where CertainTeed Apollo II - 67 (67.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CertainTeed Apollo II - 67 (67.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCertainTeed Apollo: 67.0 W

What Dataset Percentiles Define CertainTeed Apollo II - 67?

Percentile placement of CertainTeed Apollo II - 67 across power density (159.5 W/m2), thermal retention, and nameplate STC wattage.

CertainTeed Apollo II - 67 Engineering BenchmarksPercentile comparison of CertainTeed Apollo II - 67 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage67.0 WPTC/STC Retention90.9%Module Efficiency15.95%

What Do the Dataset Ranks Show for CertainTeed Apollo II - 67?

Four critical engineering numbers homeowners and solar installers check first when reviewing CertainTeed Apollo II - 67 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #21,647 / 21,677

67.0 W STC · Higher Than 0.1%

67.0 W STC (-318.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,253

15.95% Aperture Efficiency

Power density 159.5 W/m2 (3.96 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

58 Panels Max @ -10 C (600 V)

Cold Voc reaches 10.25 V at -10 C (594.5 V string) and 10.51 V at -20 C (57 max).

8 kW Reference Array

120 Panels = 8,040 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,308 W PTC; NEC 690.8 OCPD floor is 14.57 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 9.35 * (1 + (-0.275/100) * (-10 - 25)) = 10.25 V | OCPD = 1.56 * 9.34 = 14.57 A

Inputs from CEC Modules.csv for CertainTeed Apollo II - 67: Voc=9.35 V, beta_Voc=-0.275%/C, Isc=9.34 A, STC=67.0 W, Area=0.42 m2.

Result: 58 panels max on 600 V (594.5 V); 120 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for CertainTeed Apollo II - 67?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CertainTeed Apollo II - 67.

Official California Energy Commission (NREL SAM) test parameters for CertainTeed Apollo II - 67.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 67.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 60.9 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 9.35 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.34 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 7.56 V / 8.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.275 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.95% (0.42 m2) Array roof footprint density
Cell Count & Technology 14 cells (Mono-c-Si) Monofacial backsheet

How Many CertainTeed Apollo II - 67 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CertainTeed Apollo II - 67 (67.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 90 6.03 kW 407 sq ft $1,509 $2,552
8 kW Class 120 8.04 kW 543 sq ft $2,012 $3,403
10 kW Class 150 10.05 kW 678 sq ft $2,515 $4,253

How Many CertainTeed Apollo II - 67 Modules Fit in a Cold-Weather String?

Maximum series module counts for CertainTeed Apollo II - 67 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=9.35V and beta_Voc=-0.275%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 10.51 V 57 panels 599.1 V 95 panels
-10 C (14 F) 10.25 V 58 panels 594.5 V 97 panels
0 C (32 F) 9.99 V 60 panels 599.4 V 100 panels
25 C (77 F STC) 9.35 V 64 panels 598.4 V 106 panels

Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo II - 67?

Alternative CEC solar modules from competing brands near CertainTeed Apollo II - 67 (67.0 W), including Merlin Solar Technologies Inc Solstice Shingle 68W-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Merlin Solar Technologies Inc Solstice Shingle 68W-01
Merlin Solar Technologies Inc
68.0 W +1.0 W 9.37 V 12.83% 89.4%
Merlin Solar Technologies Inc Solstice Shingle 70W-01
Merlin Solar Technologies Inc
70.0 W +3.0 W 9.51 V 13.21% 89.4%
Merlin Solar Technologies Inc Solstice Shingle 72W-01
Merlin Solar Technologies Inc
72.0 W +5.0 W 9.65 V 13.58% 89.4%
HALEE Inc HST-61-E-FP
HALEE Inc
61.0 W -6.0 W 9.5 V 14.88% 85.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo II - 67?

Evaluate CertainTeed Apollo II - 67 (67.0 W STC, 9.35 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo II - 67 reaches 10.51 V per panel—exceeding 57 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 120 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 120 panels (543 sq ft).
  • 2026 tax credit baseline: cash residential installs of CertainTeed Apollo II - 67 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CertainTeed Apollo II - 67 8 kW Residential Fit

Needs 120 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 58 panels (-10 C) or 57 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 68W-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 60.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CertainTeed Apollo II - 67 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.

Why is CertainTeed Apollo II - 67 PTC wattage (60.9 W) lower than STC (67.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 60.9 W PTC (90.9% retention) across CertainTeed Apollo II - 67's 0.42 m2 aperture.

Who should skip CertainTeed Apollo II - 67 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 120 CertainTeed Apollo II - 67 panels (543 sq ft) leave unusable roof gaps vs. Merlin Solar Technologies Inc Solstice Shingle 68W-01.

What is the 1,000 V commercial string limit for CertainTeed Apollo II - 67?

On 1,000 V commercial inverters at -10 C (10.25 V cold Voc), CertainTeed Apollo II - 67 fits up to 97 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting CertainTeed Apollo II - 67.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.