CertainTeed Apollo II - 67 is a 67.0 W STC (60.9 W PTC) Mono-c-Si solar module ranking #21,647 of 21,677 CEC listings (below all-CEC median; higher than 0.1% of peers). It delivers 15.95% efficiency, 9.35 V Voc at 25 C, and 10.25 V cold Voc at -10 C (58 panels max per 600 V string).
- STC Wattage
- 67.0 W
- PTC Wattage
- 60.9 W
- Voc @ 25C
- 9.35 V
- Efficiency
- 15.95%
How Does CertainTeed Apollo II - 67 Compare Against Peer CEC Listings?
How CertainTeed CertainTeed Apollo II - 67 handles rooftop heat (60.9 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, CertainTeed Apollo II - 67 exhibits 9.34 A short-circuit current, requiring a 14.57 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,647 of 21,677 (343.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 50.4 m2 for an 8 kW system (150 panels for 10 kW). Lower 9.35 V string voltage fits 58 panels in series at 14 F and pairs easily with microinverters.
Where Does CertainTeed Apollo II - 67 Fall Across Listed CEC Models?
Where CertainTeed Apollo II - 67 (67.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define CertainTeed Apollo II - 67?
Percentile placement of CertainTeed Apollo II - 67 across power density (159.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for CertainTeed Apollo II - 67?
Four critical engineering numbers homeowners and solar installers check first when reviewing CertainTeed Apollo II - 67 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
67.0 W STC · Higher Than 0.1%
67.0 W STC (-318.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.95% Aperture Efficiency
Power density 159.5 W/m2 (3.96 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).
58 Panels Max @ -10 C (600 V)
Cold Voc reaches 10.25 V at -10 C (594.5 V string) and 10.51 V at -20 C (57 max).
120 Panels = 8,040 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,308 W PTC; NEC 690.8 OCPD floor is 14.57 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 9.35 * (1 + (-0.275/100) * (-10 - 25)) = 10.25 V | OCPD = 1.56 * 9.34 = 14.57 A
Inputs from CEC Modules.csv for CertainTeed Apollo II - 67: Voc=9.35 V, beta_Voc=-0.275%/C, Isc=9.34 A, STC=67.0 W, Area=0.42 m2.
Result: 58 panels max on 600 V (594.5 V); 120 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for CertainTeed Apollo II - 67?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CertainTeed Apollo II - 67.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 67.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 60.9 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 9.35 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.34 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 7.56 V / 8.9 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.275 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.95% (0.42 m2) | Array roof footprint density |
| Cell Count & Technology | 14 cells (Mono-c-Si) | Monofacial backsheet |
How Many CertainTeed Apollo II - 67 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CertainTeed Apollo II - 67 (67.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 90 | 6.03 kW | 407 sq ft | $1,509 | $2,552 |
| 8 kW Class | 120 | 8.04 kW | 543 sq ft | $2,012 | $3,403 |
| 10 kW Class | 150 | 10.05 kW | 678 sq ft | $2,515 | $4,253 |
How Many CertainTeed Apollo II - 67 Modules Fit in a Cold-Weather String?
Maximum series module counts for CertainTeed Apollo II - 67 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 10.51 V | 57 panels | 599.1 V | 95 panels |
| -10 C (14 F) | 10.25 V | 58 panels | 594.5 V | 97 panels |
| 0 C (32 F) | 9.99 V | 60 panels | 599.4 V | 100 panels |
| 25 C (77 F STC) | 9.35 V | 64 panels | 598.4 V | 106 panels |
Which Cross-Brand Solar Modules Compare Closest to CertainTeed Apollo II - 67?
Alternative CEC solar modules from competing brands near CertainTeed Apollo II - 67 (67.0 W), including Merlin Solar Technologies Inc Solstice Shingle 68W-01.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc Solstice Shingle 68W-01 Merlin Solar Technologies Inc |
68.0 W | +1.0 W | 9.37 V | 12.83% | 89.4% |
| Merlin Solar Technologies Inc Solstice Shingle 70W-01 Merlin Solar Technologies Inc |
70.0 W | +3.0 W | 9.51 V | 13.21% | 89.4% |
| Merlin Solar Technologies Inc Solstice Shingle 72W-01 Merlin Solar Technologies Inc |
72.0 W | +5.0 W | 9.65 V | 13.58% | 89.4% |
| HALEE Inc HST-61-E-FP HALEE Inc |
61.0 W | -6.0 W | 9.5 V | 14.88% | 85.6% |
What Are the Design Limits and Best-Fit Uses for CertainTeed Apollo II - 67?
Evaluate CertainTeed Apollo II - 67 (67.0 W STC, 9.35 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed Apollo II - 67 reaches 10.51 V per panel—exceeding 57 panels in series voids 600 V inverter warranties.
- Footprint constraint: 120 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 120 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed Apollo II - 67 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CertainTeed Apollo II - 67 8 kW Residential Fit
Needs 120 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 58 panels (-10 C) or 57 panels (-20 C), or compare Merlin Solar Technologies Inc Solstice Shingle 68W-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 60.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CertainTeed Apollo II - 67 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits.
Why is CertainTeed Apollo II - 67 PTC wattage (60.9 W) lower than STC (67.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 60.9 W PTC (90.9% retention) across CertainTeed Apollo II - 67's 0.42 m2 aperture.
Who should skip CertainTeed Apollo II - 67 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 120 CertainTeed Apollo II - 67 panels (543 sq ft) leave unusable roof gaps vs. Merlin Solar Technologies Inc Solstice Shingle 68W-01.
What is the 1,000 V commercial string limit for CertainTeed Apollo II - 67?
On 1,000 V commercial inverters at -10 C (10.25 V cold Voc), CertainTeed Apollo II - 67 fits up to 97 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting CertainTeed Apollo II - 67.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)