Skip to main content
WireAndSun
Calculators
CEC PV Module

Bluesun Solar CoLtd BSM590M10-72HNH — CEC Solar Module Specifications

Manufacturer: Bluesun Solar CoLtd Registry: CEC Verified Engineering Specification

Bluesun Solar CoLtd BSM590M10-72HNH is a 590.0 W STC (561.4 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 23.05% efficiency, 51.3 V Voc at 25 C, and 55.7 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
590.0 W
PTC Wattage
561.4 W
Voc @ 25C
51.3 V
Efficiency
23.05%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Bluesun Solar CoLtd BSM590M10-72HNH Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Bluesun Solar CoLtd BSM590M10-72HNH (Mono-c-Si) residential solar systems.

Bluesun Solar CoLtd BSM590M10-72HNH delivers 230.5 W/m2 (3.14 percentage points above 19.91% CEC median) and strong 95.2% PTC-to-STC heat retention (#399 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 56.96 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with AXITEC AC-590TGB/144TS (590.0 W).

Where Does Bluesun Solar CoLtd BSM590M10-72HNH Fall Across Listed CEC Models?

Comparison of Bluesun Solar CoLtd BSM590M10-72HNH (590.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Bluesun Solar CoLtd BSM590M10-72HNH (590.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCBluesun Solar CoLt: 590.0 W

What Dataset Percentiles Define Bluesun Solar CoLtd BSM590M10-72HNH?

Relative ranking of Bluesun Solar CoLtd BSM590M10-72HNH across nameplate watts, 95.2% PTC thermal ratio, and module aperture efficiency.

Bluesun Solar CoLtd BSM590M10-72HNH Engineering BenchmarksPercentile comparison of Bluesun Solar CoLtd BSM590M10-72HNH wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage590.0 WPTC/STC Retention95.2%Module Efficiency23.05%

What Do the Dataset Ranks Show for Bluesun Solar CoLtd BSM590M10-72HNH?

Summary of Bluesun Solar CoLtd BSM590M10-72HNH output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,597 / 21,677

Top 8.1% STC Output

590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,067

23.05% Aperture Efficiency

Power density 230.5 W/m2 (3.14 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.7 V at -10 C (557.0 V string) and 56.96 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,260 W STC

Occupies 35.8 m2 (386 sq ft) producing 7,860 W PTC; NEC 690.8 OCPD floor is 22.82 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.3 * (1 + (-0.245/100) * (-10 - 25)) = 55.7 V | OCPD = 1.56 * 14.63 = 22.82 A

Inputs from CEC Modules.csv for Bluesun Solar CoLtd BSM590M10-72HNH: Voc=51.3 V, beta_Voc=-0.245%/C, Isc=14.63 A, STC=590.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (557.0 V); 14 panels for 8 kW (386 sq ft).

What Are the Published CEC Specifications for Bluesun Solar CoLtd BSM590M10-72HNH?

Complete CEC test sheet for Bluesun Solar CoLtd BSM590M10-72HNH including Isc (14.63 A), Voc (51.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Bluesun Solar CoLtd BSM590M10-72HNH.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 590.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 561.4 W (95.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 51.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.63 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.7 V / 13.83 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.245 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.05% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Bluesun Solar CoLtd BSM590M10-72HNH Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Bluesun Solar CoLtd BSM590M10-72HNH.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.49 kW 303 sq ft $1,624 $2,747
8 kW Class 14 8.26 kW 386 sq ft $2,067 $3,496
10 kW Class 17 10.03 kW 468 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This Bluesun Solar CoLtd Series?

Related Bluesun Solar CoLtd power steps and black/silver trims consolidated into this Bluesun Solar CoLtd BSM590M10-72HNH series guide.

Sibling CEC listings grouped into the Bluesun Solar CoLtd BSM590M10-72HNH wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Bluesun Solar CoLtd BSM585M10-72HNH 585.0 W 556.5 W 51.2 V 42.5 V 22.85%
Bluesun Solar CoLtd BSM590M10-72HNH 590.0 W 561.4 W 51.3 V 42.7 V 23.05%

How Many Bluesun Solar CoLtd BSM590M10-72HNH Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Bluesun Solar CoLtd BSM590M10-72HNH (51.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=51.3V and beta_Voc=-0.245%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.96 V 10 panels 569.6 V 17 panels
-10 C (14 F) 55.7 V 10 panels 557.0 V 17 panels
0 C (32 F) 54.44 V 11 panels 598.8 V 18 panels
25 C (77 F STC) 51.3 V 11 panels 564.3 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Bluesun Solar CoLtd BSM590M10-72HNH?

Four comparable CEC modules such as AXITEC AC-590TGB/144TS (590.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-590TGB/144TS
AXITEC
590.0 W Tie (0 W) 51.7 V 23.41% 95.1%
Chint New Energy Technology Co Ltd CHSM72N-HC-585
Chint New Energy Technology Co Ltd
585.0 W -5.0 W 51.3 V 22.67% 94.7%
Chint New Energy Technology Co Ltd CHSM72RN-HC-595
Chint New Energy Technology Co Ltd
595.0 W +5.0 W 51.2 V 22.97% 94.6%
AE Solar GmbH AE585CMD-144BDS
AE Solar GmbH
585.0 W -5.0 W 51.6 V 22.67% 95.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Bluesun Solar CoLtd BSM590M10-72HNH?

Evaluate Bluesun Solar CoLtd BSM590M10-72HNH (590.0 W STC, 51.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Bluesun Solar CoLtd BSM590M10-72HNH reaches 56.96 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Bluesun Solar CoLtd BSM590M10-72HNH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Bluesun Solar CoLtd BSM590M10-72HNH 8 kW Residential Fit

Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-590TGB/144TS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 561.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Bluesun Solar CoLtd BSM590M10-72HNH by Bluesun Solar CoLtd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Bluesun Solar CoLtd BSM590M10-72HNH panels fit on a 600 V winter solar string?

At -10 C (14 F), Bluesun Solar CoLtd BSM590M10-72HNH cold Voc rises from 51.3 V to 55.7 V (beta_Voc -0.245%/C), capping a 600 V string at 10 panels (557.0 V).

How much roof area does an 8 kW array of Bluesun Solar CoLtd BSM590M10-72HNH need?

An 8 kW DC system uses 14 Bluesun Solar CoLtd BSM590M10-72HNH modules (8,260 W STC / 7,860 W PTC), covering roughly 386 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

How does Bluesun Solar CoLtd BSM590M10-72HNH compare against AXITEC AC-590TGB/144TS?

Bluesun Solar CoLtd BSM590M10-72HNH outputs 590.0 W STC (51.3 V Voc, rank #1,597 of 21,677), while AXITEC AC-590TGB/144TS delivers 590.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.