AXITEC AC-460TGB/96BB is a 460.0 W STC (435.7 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 23.71% efficiency, 36.3 V Voc at 25 C, and 39.4 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 460.0 W
- PTC Wattage
- 435.7 W
- Voc @ 25C
- 36.3 V
- Efficiency
- 23.71%
How Does AXITEC AC-460TGB/96BB Compare Against Peer CEC Listings?
Solar engineering breakdown for AXITEC AC-460TGB/96BB: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Measured at 460.0 W STC and 435.7 W PTC, AXITEC AC-460TGB/96BB sits +75.0 W vs all-CEC median (top 25.0%; higher than 75.0% of peers) among 21,677 listed modules. Power density reaches 237.1 W/m2 (3.80 percentage points above 19.91% CEC median). Lower 36.3 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 25 panels in series. Alternative peer ELITE Solar ET-NR48TBH460GB rates 460.0 W.
Where Does AXITEC AC-460TGB/96BB Fall Across Listed CEC Models?
Distribution marker showing AXITEC AC-460TGB/96BB (460.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define AXITEC AC-460TGB/96BB?
Dataset percentiles tracking AXITEC AC-460TGB/96BB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for AXITEC AC-460TGB/96BB?
Benchmark highlights for AXITEC AC-460TGB/96BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Top 25.0% STC Output
460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.71% Aperture Efficiency
Power density 237.1 W/m2 (3.80 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 39.4 V at -10 C (591.0 V string) and 40.29 V at -20 C (14 max).
18 Panels = 8,280 W STC
Occupies 34.9 m2 (376 sq ft) producing 7,843 W PTC; NEC 690.8 OCPD floor is 24.94 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.3 * (1 + (-0.244/100) * (-10 - 25)) = 39.4 V | OCPD = 1.56 * 15.99 = 24.94 A
Inputs from CEC Modules.csv for AXITEC AC-460TGB/96BB: Voc=36.3 V, beta_Voc=-0.244%/C, Isc=15.99 A, STC=460.0 W, Area=1.94 m2.
Result: 15 panels max on 600 V (591.0 V); 18 panels for 8 kW (376 sq ft).
What Are the Published CEC Specifications for AXITEC AC-460TGB/96BB?
Official CEC datasheet figures for AXITEC AC-460TGB/96BB (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 460.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 435.7 W (94.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.4 V / 15.14 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.244 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.71% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 16 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-460TGB/96BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many AXITEC AC-460TGB/96BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.44 kW | 292 sq ft | $1,612 | $2,726 |
| 8 kW Class | 18 | 8.28 kW | 376 sq ft | $2,072 | $3,504 |
| 10 kW Class | 22 | 10.12 kW | 459 sq ft | $2,533 | $4,283 |
How Many AXITEC AC-460TGB/96BB Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-460TGB/96BB (39.4 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 40.29 V | 14 panels | 564.1 V | 24 panels |
| -10 C (14 F) | 39.4 V | 15 panels | 591.0 V | 25 panels |
| 0 C (32 F) | 38.51 V | 15 panels | 577.6 V | 25 panels |
| 25 C (77 F STC) | 36.3 V | 16 panels | 580.8 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-460TGB/96BB?
Competing CEC solar panels closest to AXITEC AC-460TGB/96BB in nameplate wattage and Voc, starting with ELITE Solar ET-NR48TBH460GB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ELITE Solar ET-NR48TBH460GB ELITE Solar |
460.0 W | Tie (0 W) | 36.09 V | 23.0% | 95.1% |
| ELITE Solar ET-NR48TBH460GL ELITE Solar |
460.0 W | Tie (0 W) | 36.09 V | 23.0% | 95.1% |
| G-Star Pte Ltd GSD8R48T-460BT G-Star Pte Ltd |
460.0 W | Tie (0 W) | 35.99 V | 23.23% | 95.2% |
| G-Star Pte Ltd GSD8R48T-460WT G-Star Pte Ltd |
460.0 W | Tie (0 W) | 35.99 V | 23.23% | 95.2% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-460TGB/96BB?
Evaluate AXITEC AC-460TGB/96BB (460.0 W STC, 36.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-460TGB/96BB reaches 40.29 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-460TGB/96BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-460TGB/96BB 8 kW Residential Fit
Needs 18 modules (376 sq ft) with a 25 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare ELITE Solar ET-NR48TBH460GB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 435.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-460TGB/96BB by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-460TGB/96BB panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-460TGB/96BB cold Voc rises from 36.3 V to 39.4 V (beta_Voc -0.244%/C), capping a 600 V string at 15 panels (591.0 V).
How much roof area does an 8 kW array of AXITEC AC-460TGB/96BB need?
An 8 kW DC system uses 18 AXITEC AC-460TGB/96BB modules (8,280 W STC / 7,843 W PTC), covering roughly 376 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does AXITEC AC-460TGB/96BB compare against ELITE Solar ET-NR48TBH460GB?
AXITEC AC-460TGB/96BB outputs 460.0 W STC (36.3 V Voc, rank #5,199 of 21,677), while ELITE Solar ET-NR48TBH460GB delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)