AXITEC AC-375MH/120VB is a 375.0 W STC (350.4 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.72% efficiency, 41.1 V Voc at 25 C, and 45.14 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 350.4 W
- Voc @ 25C
- 41.1 V
- Efficiency
- 20.72%
How Does AXITEC AC-375MH/120VB Compare Against Peer CEC Listings?
Engineering position of AXITEC AC-375MH/120VB (375.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W across 5,889 CEC Mono-c-Si solar modules.
Ranking #11,367 across 21,677 CEC solar panels (below all-CEC median; higher than 46.0% of peers), AXITEC AC-375MH/120VB operates as a compact residential or specialty off-grid module sitting 35.0 W below the 410.0 W Mono-c-Si median. Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677), 22 panels occupy 429 sq ft and offset roughly $2,065/yr at average US rates (or $3,492/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does AXITEC AC-375MH/120VB Fall Across Listed CEC Models?
Plots AXITEC AC-375MH/120VB at 375.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-375MH/120VB?
Benchmarks AXITEC AC-375MH/120VB on STC wattage, thermal PTC/STC retention, and 20.72 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AXITEC AC-375MH/120VB?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-375MH/120VB by AXITEC.
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.72% Aperture Efficiency
Power density 207.2 W/m2 (0.81 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.14 V at -10 C (586.8 V string) and 46.3 V at -20 C (12 max).
22 Panels = 8,250 W STC
Occupies 39.8 m2 (429 sq ft) producing 7,709 W PTC; NEC 690.8 OCPD floor is 18.1 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.1 * (1 + (-0.281/100) * (-10 - 25)) = 45.14 V | OCPD = 1.56 * 11.6 = 18.1 A
Inputs from CEC Modules.csv for AXITEC AC-375MH/120VB: Voc=41.1 V, beta_Voc=-0.281%/C, Isc=11.6 A, STC=375.0 W, Area=1.81 m2.
Result: 13 panels max on 600 V (586.8 V); 22 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for AXITEC AC-375MH/120VB?
Laboratory test ratings recorded for AXITEC AC-375MH/120VB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 350.4 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.6 V / 10.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.72% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-375MH/120VB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (429 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-375MH/120VB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 312 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 429 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 526 sq ft | $2,533 | $4,283 |
How Many AXITEC AC-375MH/120VB Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AXITEC AC-375MH/120VB (beta_Voc -0.281%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.3 V | 12 panels | 555.6 V | 21 panels |
| -10 C (14 F) | 45.14 V | 13 panels | 586.8 V | 22 panels |
| 0 C (32 F) | 43.99 V | 13 panels | 571.9 V | 22 panels |
| 25 C (77 F STC) | 41.1 V | 14 panels | 575.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-375MH/120VB?
Closest cross-brand CEC competitors to AXITEC AC-375MH/120VB matched near 375.0 W STC and 41.1 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 21.07% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.49% | 93.4% |
| Dehui Solar Power (Vietnam) CoLtd DH-M760B 375W Dehui Solar Power (Vietnam) CoLtd |
375.0 W | Tie (0 W) | 41.1 V | 20.49% | 93.4% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-375MH/120VB?
Evaluate AXITEC AC-375MH/120VB (375.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-375MH/120VB reaches 46.3 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-375MH/120VB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-375MH/120VB 8 kW Residential Fit
Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 350.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-375MH/120VB by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-375MH/120VB panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-375MH/120VB cold Voc rises from 41.1 V to 45.14 V (beta_Voc -0.281%/C), capping a 600 V string at 13 panels (586.8 V).
How much roof area does an 8 kW array of AXITEC AC-375MH/120VB need?
An 8 kW DC system uses 22 AXITEC AC-375MH/120VB modules (8,250 W STC / 7,709 W PTC), covering roughly 429 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does AXITEC AC-375MH/120VB compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W?
AXITEC AC-375MH/120VB outputs 375.0 W STC (41.1 V Voc, rank #11,367 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W delivers 375.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)