Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Yaskawa Solectria Solar: SGI 750XTM {380V} — CEC Inverter Specifications

Manufacturer: Yaskawa Solectria Solar Registry: CEC Verified Engineering Specification

Yaskawa Solectria Solar: SGI 750XTM {380V} outputs 753,200 W AC at 380 V, 3-phase (1144.4 A continuous, 1,450 A OCPD), ranking #1,116 of 2,343 CEC inverters at 96.91% efficiency with a 545-820 V MPPT window and 820 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
753,200 W
AC Voltage
380 V, 3-phase
Min PV Breaker
1,450 A (parallel Cu feeders)
CEC Efficiency
96.91%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Yaskawa Solectria Solar: SGI 750XTM {380V} Compare Against Peer CEC Listings?

Breaker sizing (1,450 A), parallel Cu feeders wire rules, and DC input limits for Yaskawa Solectria Solar: SGI 750XTM {380V}.

For NEC 705.12 solar interconnection, Yaskawa Solectria Solar: SGI 750XTM {380V} outputs 1144.4 A continuous AC at 380 V, 3-phase and needs a 1,450 A backfeed breaker on parallel Cu feeders (75 C). Commercial 380 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (380V) or NEC 705.11 supply-side tap. Conversion efficiency scores 96.91% (#1,116 of 2,343, +0.09 pts vs overall CEC median).

Where Does Yaskawa Solectria Solar: SGI 750XTM {380V} Fall Across Listed CEC Models?

Output power comparison showing where Yaskawa Solectria Solar: SGI 750XTM {380V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Yaskawa Solectria Solar: SGI 750XTM {380V} (753,200 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACYaskawa Solectria : 753,200 W

What Dataset Percentiles Define Yaskawa Solectria Solar: SGI 750XTM {380V}?

Relative ranking of Yaskawa Solectria Solar: SGI 750XTM {380V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Yaskawa Solectria Solar: SGI 750XTM {380V} Technical ThresholdsPercentile comparison for Yaskawa Solectria Solar: SGI 750XTM {380V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output753,200 WCEC Efficiency96.91%Backfeed Breaker1,450 A

What Do the Dataset Ranks Show for Yaskawa Solectria Solar: SGI 750XTM {380V}?

Snapshot of Yaskawa Solectria Solar: SGI 750XTM {380V} efficiency rank (#1,116), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,116 / 2,343

96.91% CEC Weighted Efficiency

-0.17 pts vs the 97.08% 380 V median; overall power rank #183 (753,200 W, top 7.8%; higher than 92.2% of peers).

NEC 705.12 Check

1,450 A Required Backfeed OCPD

125% x 1144.4 A = 1430.5 A -> 1,450 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

545 V - 820 V (Max 820 V DC)

Tracking span of 275.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 380 V, 3-phase switchgear (200A Bus / 200A Main (380V) to 1,200A Bus / 1,200A Main (380V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 753200.0W / 380 V 3-phase -> 1144.4 A | Breaker >= 1.25 * 1144.4 = 1430.5 A -> 1,450 A

CEC Inverters.csv for Yaskawa Solectria Solar: SGI 750XTM {380V}: Paco=753200.0 W, Vac=380 V, Vdcmax=820.0 V, Eff=96.91%.

Result: Min 1,450 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (380V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Yaskawa Solectria Solar: SGI 750XTM {380V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Yaskawa Solectria Solar: SGI 750XTM {380V}.

Official California Energy Commission (NREL SAM) test parameters for Yaskawa Solectria Solar: SGI 750XTM {380V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 753,200 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 380 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 820 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 545 V - 820 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1263.77 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.91% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Yaskawa Solectria Solar: SGI 750XTM {380V} (380 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Yaskawa Solectria Solar: SGI 750XTM {380V} at 380 V, 3-phase.

Evaluates Yaskawa Solectria Solar: SGI 750XTM {380V} (1450 A required OCPD at 380 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (380V) 40 A 1,450 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (380V) 80 A 1,450 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (380V) 120 A 1,450 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (380V) 160 A 1,450 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (380V) 240 A 1,450 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Yaskawa Solectria Solar: SGI 750XTM {380V}?

Minimum and maximum series solar module strings fitting Yaskawa Solectria Solar: SGI 750XTM {380V} MPPT and 820 V limits.

Sampled CEC PV modules aligned within 545.0-820.0 V MPPT and 820.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 13 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 17 to 19 panels 8.36 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 16 to 18 panels 7.65 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 19 to 20 panels 4.0 kW

Which Competing Grid-Support Inverters Compare to Yaskawa Solectria Solar: SGI 750XTM {380V}?

Peer 380 V, 3-phase CEC inverters near 753,200 W AC output such as EPC Power Corp: 50-200100 {720V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EPC Power Corp: 50-200100 {720V}
EPC Power Corp
561,806 W -191394 W 720.0 V 1500.0 V 98.58%
ABB: PVS-175-TL-POWER-MODULE-1-US {800V}
ABB
179,574 W -573626 W 800.0 V 1200.0 V 97.39%
LS Energy Solutions LLC: PBE-6140-R61-1A0-1000 {600V}
LS Energy Solutions LLC
139,449 W -613751 W 600.0 V 1350.0 V 98.27%
JingTsing Technology Ltd: JTES-PCS125K-1000/480-L03C1 {480V}
JingTsing Technology Ltd
127,819 W -625381 W 480.0 V 950.0 V 98.0%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Yaskawa Solectria Solar: SGI 750XTM {380V}?

Check Yaskawa Solectria Solar: SGI 750XTM {380V} (753,200 W AC, 1,450 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 380 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (380V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 820 V DC on Yaskawa Solectria Solar: SGI 750XTM {380V}.

Yaskawa Solectria Solar: SGI 750XTM {380V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,450 A OCPD breaker (1144.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.91%) and MPPT window (545-820 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Yaskawa Solectria Solar: SGI 750XTM {380V} by Yaskawa Solectria Solar covering breaker sizing, MPPT limits, and 380 V, 3-phase interconnection.

What breaker and wire size does Yaskawa Solectria Solar: SGI 750XTM {380V} require?

At 753,200 W continuous AC (380 V, 3-phase), continuous current is 1144.4 A; 125% NEC 690.8/705.12 sizing requires a 1,450 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Yaskawa Solectria Solar: SGI 750XTM {380V} require?

At 753,200 W AC and 380 V, 3-phase, continuous line current is 1144.4 A, requiring a 1,450 A OCPD and 1,200A Bus / 1,200A Main (380V) or NEC 705.11 interconnection.

How does Yaskawa Solectria Solar: SGI 750XTM {380V} compare to EPC Power Corp: 50-200100 {720V}?

Yaskawa Solectria Solar: SGI 750XTM {380V} delivers 753,200 W AC at 96.91% CEC efficiency with a 820 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 380 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.