Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

WSTECH GmbH: APS1600-PV-2-440-5 {440V} — CEC Inverter Specifications

Manufacturer: WSTECH GmbH Registry: CEC Verified Engineering Specification

WSTECH GmbH: APS1600-PV-2-440-5 {440V} outputs 1,626,952 W AC at 440 V, 3-phase (2134.9 A continuous, 2,700 A OCPD), ranking #550 of 2,343 CEC inverters at 97.49% efficiency with a 648-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,626,952 W
AC Voltage
440 V, 3-phase
Min PV Breaker
2,700 A (parallel Cu feeders)
CEC Efficiency
97.49%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WSTECH GmbH: APS1600-PV-2-440-5 {440V} Compare Against Peer CEC Listings?

How WSTECH GmbH WSTECH GmbH: APS1600-PV-2-440-5 {440V} compares on 97.49% efficiency, MPPT span, and 120% busbar interconnection. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

With a 648-1,500 V MPPT tracking band and 1,500 V DC ceiling, WSTECH GmbH: APS1600-PV-2-440-5 {440V} handles 1,626,952 W continuous AC (577,299 W above the 1,049,653 W 440 V median). Commercial 440 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (440V) or NEC 705.11 supply-side tap. Installers comparing WSTECH GmbH against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

Where Does WSTECH GmbH: APS1600-PV-2-440-5 {440V} Fall Across Listed CEC Models?

Position of WSTECH GmbH: APS1600-PV-2-440-5 {440V} (1,626,952 W AC) relative to the 7,680 W CEC median inverter. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where WSTECH GmbH: APS1600-PV-2-440-5 {440V} (1,626,952 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACWSTECH GmbH: APS16: 1,626,952 W

What Dataset Percentiles Define WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Percentile placement of WSTECH GmbH: APS1600-PV-2-440-5 {440V} across AC power class, conversion efficiency, and backfeed breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

WSTECH GmbH: APS1600-PV-2-440-5 {440V} Technical ThresholdsPercentile comparison for WSTECH GmbH: APS1600-PV-2-440-5 {440V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,626,952 WCEC Efficiency97.49%Backfeed Breaker2,700 A

What Do the Dataset Ranks Show for WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for WSTECH GmbH: APS1600-PV-2-440-5 {440V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #550 / 2,343

97.49% CEC Weighted Efficiency

+0.02 pts vs the 97.47% 440 V median; overall power rank #124 (1,626,952 W, top 5.3%; higher than 94.7% of peers).

NEC 705.12 Check

2,700 A Required Backfeed OCPD

125% x 2134.9 A = 2668.6 A -> 2,700 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

648 V - 1,500 V (Max 1,500 V DC)

Tracking span of 852.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 440 V, 3-phase switchgear (200A Bus / 200A Main (440V) to 1,200A Bus / 1,200A Main (440V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1626952.0W / 440 V 3-phase -> 2134.9 A | Breaker >= 1.25 * 2134.9 = 2668.6 A -> 2,700 A

CEC Inverters.csv for WSTECH GmbH: APS1600-PV-2-440-5 {440V}: Paco=1626952.0 W, Vac=440 V, Vdcmax=1500.0 V, Eff=97.49%.

Result: Min 2,700 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (440V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for WSTECH GmbH: APS1600-PV-2-440-5 {440V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for WSTECH GmbH: APS1600-PV-2-440-5 {440V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,626,952 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 440 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 648 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1668.84 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.49% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to WSTECH GmbH: APS1600-PV-2-440-5 {440V} (440 V, 3-phase)?

Check whether WSTECH GmbH: APS1600-PV-2-440-5 {440V} (2,700 A breaker) fits without main breaker derate or supply-side taps. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Evaluates WSTECH GmbH: APS1600-PV-2-440-5 {440V} (2700 A required OCPD at 440 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (440V) 40 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (440V) 80 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (440V) 120 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (440V) 160 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (440V) 240 A 2,700 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Verified cold-weather (-10 C) series module counts matched to WSTECH GmbH: APS1600-PV-2-440-5 {440V}'s 1,500 V DC ceiling.

Sampled CEC PV modules aligned within 648.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 16 to 26 panels 15.34 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 20 to 35 panels 15.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 19 to 33 panels 14.03 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 23 to 36 panels 7.2 kW

Which Competing Grid-Support Inverters Compare to WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Alternative CEC inverters comparable to WSTECH GmbH: APS1600-PV-2-440-5 {440V}, including Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W) at 440 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W +39048 W 575.0 V 1200.0 V 97.54%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W +99748 W 690.0 V 1500.0 V 98.32%
Power Electronics: FS2250CU15O3 {600V}
Power Electronics
2,420,370 W +793418 W 600.0 V 1200.0 V 97.82%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}
INGETEAM POWER TECHNOLOGY SA
2,467,620 W +840668 W 480.0 V 1300.0 V 96.63%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for WSTECH GmbH: APS1600-PV-2-440-5 {440V}?

Check WSTECH GmbH: APS1600-PV-2-440-5 {440V} (1,626,952 W AC, 2,700 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 440 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (440V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on WSTECH GmbH: APS1600-PV-2-440-5 {440V}.

WSTECH GmbH: APS1600-PV-2-440-5 {440V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,700 A OCPD breaker (2134.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.49%) and MPPT window (648-1,500 V) directly against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for WSTECH GmbH: APS1600-PV-2-440-5 {440V} by WSTECH GmbH covering breaker sizing, MPPT limits, and 440 V, 3-phase interconnection.

What breaker and wire size does WSTECH GmbH: APS1600-PV-2-440-5 {440V} require?

At 1,626,952 W continuous AC (440 V, 3-phase), continuous current is 2134.9 A; 125% NEC 690.8/705.12 sizing requires a 2,700 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does WSTECH GmbH: APS1600-PV-2-440-5 {440V} require?

At 1,626,952 W AC and 440 V, 3-phase, continuous line current is 2134.9 A, requiring a 2,700 A OCPD and 1,200A Bus / 1,200A Main (440V) or NEC 705.11 interconnection.

How does WSTECH GmbH: APS1600-PV-2-440-5 {440V} compare to Schneider Electric USA Inc: CS1666-3-NA {575V}?

WSTECH GmbH: APS1600-PV-2-440-5 {440V} delivers 1,626,952 W AC at 97.49% CEC efficiency with a 1,500 V DC ceiling, while Schneider Electric USA Inc: CS1666-3-NA {575V} outputs 1,666,000 W at 440 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.