WSTECH GmbH: APS1600-ES-2-440-5 {440V} outputs 1,626,952 W AC at 440 V, 3-phase (2134.9 A continuous, 2,700 A OCPD), ranking #550 of 2,343 CEC inverters at 97.49% efficiency with a 648-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,626,952 W
- AC Voltage
- 440 V, 3-phase
- Min PV Breaker
- 2,700 A (parallel Cu feeders)
- CEC Efficiency
- 97.49%
How Does WSTECH GmbH: APS1600-ES-2-440-5 {440V} Compare Against Peer CEC Listings?
CEC efficiency rank (#550), 648-1,500 V MPPT tracking, and panel fit for WSTECH GmbH: APS1600-ES-2-440-5 {440V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
WSTECH GmbH: APS1600-ES-2-440-5 {440V} from WSTECH GmbH outputs 2134.9 A continuous AC at 440 V, 3-phase (1,626,952 W AC, rank #124). Paired with parallel Cu feeders conductors and a 2,700 A OCPD, its 97.49% CEC efficiency compares closely with Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W). Keep NEC 690.7 winter string Voc below 1,500 V DC.
Where Does WSTECH GmbH: APS1600-ES-2-440-5 {440V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting WSTECH GmbH: APS1600-ES-2-440-5 {440V} at 1,626,952 W continuous AC output. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define WSTECH GmbH: APS1600-ES-2-440-5 {440V}?
Dataset percentiles comparing WSTECH GmbH: APS1600-ES-2-440-5 {440V} against 2,343 certified grid-support inverters nationwide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Do the Dataset Ranks Show for WSTECH GmbH: APS1600-ES-2-440-5 {440V}?
Engineering highlights for WSTECH GmbH: APS1600-ES-2-440-5 {440V} covering efficiency, parallel Cu feeders feeder, and panel compatibility. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
97.49% CEC Weighted Efficiency
+0.02 pts vs the 97.47% 440 V median; overall power rank #124 (1,626,952 W, top 5.3%; higher than 94.7% of peers).
2,700 A Required Backfeed OCPD
125% x 2134.9 A = 2668.6 A -> 2,700 A standard OCPD using parallel Cu feeders (75 C).
648 V - 1,500 V (Max 1,500 V DC)
Tracking span of 852.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 440 V, 3-phase switchgear (200A Bus / 200A Main (440V) to 1,200A Bus / 1,200A Main (440V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1626952.0W / 440 V 3-phase -> 2134.9 A | Breaker >= 1.25 * 2134.9 = 2668.6 A -> 2,700 A
CEC Inverters.csv for WSTECH GmbH: APS1600-ES-2-440-5 {440V}: Paco=1626952.0 W, Vac=440 V, Vdcmax=1500.0 V, Eff=97.49%.
Result: Min 2,700 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (440V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for WSTECH GmbH: APS1600-ES-2-440-5 {440V}?
California Energy Commission Solar Equipment List parameters for WSTECH GmbH: APS1600-ES-2-440-5 {440V} (grid-tied PV inverter) interconnection. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,626,952 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 440 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 648 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 1668.84 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.49% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to WSTECH GmbH: APS1600-ES-2-440-5 {440V} (440 V, 3-phase)?
Panelboard and switchgear backfeed allowances for WSTECH GmbH: APS1600-ES-2-440-5 {440V} (2,700 A OCPD). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (440V) | 40 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (440V) | 80 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (440V) | 120 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (440V) | 160 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (440V) | 240 A | 2,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With WSTECH GmbH: APS1600-ES-2-440-5 {440V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for WSTECH GmbH: APS1600-ES-2-440-5 {440V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 16 to 26 panels | 15.34 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 20 to 35 panels | 15.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 19 to 33 panels | 14.03 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 23 to 36 panels | 7.2 kW |
Which Competing Grid-Support Inverters Compare to WSTECH GmbH: APS1600-ES-2-440-5 {440V}?
Four alternative CEC inverters matched to WSTECH GmbH: APS1600-ES-2-440-5 {440V} (1,626,952 W AC), led by Schneider Electric USA Inc: CS1666-3-NA {575V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Schneider Electric USA Inc: CS1666-3-NA {575V} Schneider Electric USA Inc |
1,666,000 W | +39048 W | 575.0 V | 1200.0 V | 97.54% |
| SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} SINENG ELECTRIC CO LTD |
1,726,700 W | +99748 W | 690.0 V | 1500.0 V | 98.32% |
| Power Electronics: FS2250CU15O3 {600V} Power Electronics |
2,420,370 W | +793418 W | 600.0 V | 1200.0 V | 97.82% |
| INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} INGETEAM POWER TECHNOLOGY SA |
2,467,620 W | +840668 W | 480.0 V | 1300.0 V | 96.63% |
What Are the Interconnection Limits and Best-Fit Uses for WSTECH GmbH: APS1600-ES-2-440-5 {440V}?
Check WSTECH GmbH: APS1600-ES-2-440-5 {440V} (1,626,952 W AC, 2,700 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 440 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (440V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on WSTECH GmbH: APS1600-ES-2-440-5 {440V}.
WSTECH GmbH: APS1600-ES-2-440-5 {440V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 2,700 A OCPD breaker (2134.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.49%) and MPPT window (648-1,500 V) directly against Schneider Electric USA Inc: CS1666-3-NA {575V} (1,666,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for WSTECH GmbH: APS1600-ES-2-440-5 {440V} by WSTECH GmbH covering breaker sizing, MPPT limits, and 440 V, 3-phase interconnection.
What breaker and wire size does WSTECH GmbH: APS1600-ES-2-440-5 {440V} require?
At 1,626,952 W continuous AC (440 V, 3-phase), continuous current is 2134.9 A; 125% NEC 690.8/705.12 sizing requires a 2,700 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does WSTECH GmbH: APS1600-ES-2-440-5 {440V} require?
At 1,626,952 W AC and 440 V, 3-phase, continuous line current is 2134.9 A, requiring a 2,700 A OCPD and 1,200A Bus / 1,200A Main (440V) or NEC 705.11 interconnection.
How does WSTECH GmbH: APS1600-ES-2-440-5 {440V} compare to Schneider Electric USA Inc: CS1666-3-NA {575V}?
WSTECH GmbH: APS1600-ES-2-440-5 {440V} delivers 1,626,952 W AC at 97.49% CEC efficiency with a 1,500 V DC ceiling, while Schneider Electric USA Inc: CS1666-3-NA {575V} outputs 1,666,000 W at 440 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)