VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} outputs 9,019 W AC at 240 V (37.6 A continuous, 50 A OCPD), ranking #2,061 of 2,343 CEC inverters at 95.82% efficiency with a 285-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 9,019 W
- AC Voltage
- 240 V
- Min PV Breaker
- 50 A (8 AWG Cu)
- CEC Efficiency
- 95.82%
How Does VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} Compare Against Peer CEC Listings?
Breaker sizing (50 A), 8 AWG Cu wire rules, and DC input limits for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}.
Classified as a hybrid battery-capable inverter (listed since 2024-11-01), VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} requires 47.0 A design capacity -> 50 A breaker using 8 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 95.82% (-1.00 pts vs overall CEC median) across 2,343 CEC models, while its 50 a backfeed breaker exceeds a 200a/200a panel's 40 a ceiling, requiring a 175 a main derate, 225 a busbar, or nec 705.11 tap.
Where Does VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} Fall Across Listed CEC Models?
Output power comparison showing where VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} sits among all 2,343 CEC-listed grid-support inverters.
What Dataset Percentiles Define VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}?
Relative ranking of VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}?
Snapshot of VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} efficiency rank (#2,061), OCPD breaker size, MPPT span, and busbar verdict.
95.82% CEC Weighted Efficiency
-0.86 pts vs the 96.68% 240 V median; overall power rank #1,014 (9,019 W, top 43.6%; higher than 56.4% of peers).
50 A Required Backfeed OCPD
125% x 37.6 A = 47.0 A -> 50 A standard OCPD using 8 AWG Cu (75 C).
285 V - 500 V (Max 500 V DC)
Tracking span of 215.0 V; listed since 2024-11-01 (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 9018.6W / 240 V -> 37.6 A | Breaker >= 1.25 * 37.6 = 47.0 A -> 50 A
CEC Inverters.csv for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}: Paco=9018.6 W, Vac=240 V, Vdcmax=500.0 V, Eff=95.82%.
Result: Min 50 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 9,019 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 285 V - 500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 26.1433 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.82% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2024-11-01 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}?
NEC 705.12(B)(3)(2) backfeed compliance table for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} at 240 V.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 50 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 50 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 50 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 50 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 50 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}?
Minimum and maximum series solar module strings fitting VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} MPPT and 500 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 to 11 panels | 4.67 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 10 to 12 panels | 2.4 kW |
Which Competing Grid-Support Inverters Compare to VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}?
Peer 240 V CEC inverters near 9,019 W AC output such as Base Power Inc: MIN 9000TL-XH-US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Base Power Inc: MIN 9000TL-XH-US {240V} Base Power Inc |
9,063 W | +44 W | 240.0 V | 480.0 V | 97.69% |
| ABB: UNO-86-TL-OUTD-S-US-A {240V} ABB |
8,600 W | -419 W | 240.0 V | 480.0 V | 97.03% |
| ABB: UNO-86-TL-OUTD-S-US-Z-A {240V} ABB |
8,600 W | -419 W | 240.0 V | 480.0 V | 97.03% |
| ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V} ABB |
8,600 W | -419 W | 240.0 V | 480.0 V | 97.03% |
What Are the Interconnection Limits and Best-Fit Uses for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}?
Check VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} (9,019 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V}.
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (37.6 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.82%) and MPPT window (285-500 V) directly against Base Power Inc: MIN 9000TL-XH-US {240V} (9,063 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} by VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} require?
At 9,019 W continuous AC (240 V), continuous current is 37.6 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.
Does VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 50 A at 240 V means Needs Derate / Tap 705.11.
How does VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} compare to Base Power Inc: MIN 9000TL-XH-US {240V}?
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V} delivers 9,019 W AC at 95.82% CEC efficiency with a 500 V DC ceiling, while Base Power Inc: MIN 9000TL-XH-US {240V} outputs 9,063 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)