Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} outputs 5,519 W AC at 240 V (23.0 A continuous, 30 A OCPD), ranking #2,266 of 2,343 CEC inverters at 94.79% efficiency with a 240-520 V MPPT window and 520 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 5,519 W
- AC Voltage
- 240 V
- Min PV Breaker
- 30 A (10 AWG Cu)
- CEC Efficiency
- 94.79%
How Does Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}.
Rated at 5,519 W AC (23.0 A continuous), Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} ranks #2,266 of 2,343 CEC units at 94.79% efficiency (-1.89 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 30 A circuit is 10 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 520 V DC at record local winter lows.
Where Does Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} Fall Across Listed CEC Models?
Marks Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} (5,519 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}?
Benchmarks Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} continuous AC output, 94.79% CEC weighted efficiency, and 30 A OCPD breaker demand.
What Do the Dataset Ranks Show for Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} by Tabuchi Electric Co Ltd.
94.79% CEC Weighted Efficiency
-1.89 pts vs the 96.68% 240 V median; overall power rank #1,454 (5,519 W, below CEC median; higher than 37.9% of peers).
30 A Required Backfeed OCPD
125% x 23.0 A = 28.8 A -> 30 A standard OCPD using 10 AWG Cu (75 C).
240 V - 520 V (Max 520 V DC)
Tracking span of 280.0 V; listed since 2018-10-15 (hybrid battery-capable inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 5518.9W / 240 V -> 23.0 A | Breaker >= 1.25 * 23.0 = 28.8 A -> 30 A
CEC Inverters.csv for Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}: Paco=5518.9 W, Vac=240 V, Vdcmax=520.0 V, Eff=94.79%.
Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 5,519 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 520 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 240 V - 520 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 15.3212 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 94.79% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2018-10-15 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}?
Evaluates Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} (30 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 30 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 30 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 30 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 30 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 30 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}?
Sample PV string lengths aligned within 240-520 V MPPT and 520 V DC max at -10 C. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 6 to 9 panels | 5.31 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 8 to 12 panels | 5.28 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 7 to 11 panels | 4.67 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 9 to 12 panels | 2.4 kW |
Which Competing Grid-Support Inverters Compare to Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}?
Competing CEC grid-support inverters near 5,519 W AC and 240 V, led by Delta Electronics: E6-TL-US {240V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: E6-TL-US {240V} Delta Electronics |
5,760 W | +241 W | 240.0 V | 480.0 V | 97.35% |
| Delta Electronics: M6-TL-US {240V} Delta Electronics |
5,760 W | +241 W | 240.0 V | 480.0 V | 97.37% |
| Delta Electronics: E6_BDI {240V} Delta Electronics |
5,823 W | +304 W | 240.0 V | 480.0 V | 97.63% |
| Delta Electronics: SOLIVIA 52 NA G4 TL {240V} Delta Electronics |
5,200 W | -319 W | 240.0 V | 500.0 V | 97.88% |
What Are the Interconnection Limits and Best-Fit Uses for Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}?
Check Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} (5,519 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 520 V DC on Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V}.
Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} Panel & Wire Spec
Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (23.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (94.79%) and MPPT window (240-520 V) directly against Delta Electronics: E6-TL-US {240V} (5,760 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} by Tabuchi Electric Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} require?
At 5,519 W continuous AC (240 V), continuous current is 23.0 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.
Does Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).
How does Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} compare to Delta Electronics: E6-TL-US {240V}?
Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V} delivers 5,519 W AC at 94.79% CEC efficiency with a 520 V DC ceiling, while Delta Electronics: E6-TL-US {240V} outputs 5,760 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)