Manufacturer: Sungrow Registry: CEC Verified Engineering Specification

Sungrow: SG36CX-US {480V} outputs 36,046 W AC at 480 V, 3-phase (43.4 A continuous, 60 A OCPD), ranking #350 of 2,343 CEC inverters at 97.99% efficiency with a 550-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
36,046 W
AC Voltage
480 V, 3-phase
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
97.99%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sungrow: SG36CX-US {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for Sungrow: SG36CX-US {480V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rated at 36,046 W AC (43.4 A continuous), Sungrow: SG36CX-US {480V} ranks #350 of 2,343 CEC units at 97.99% efficiency (-0.03 pts vs the 98.02% 480 V median). Minimum 75 C copper conductor sizing for its 60 A circuit is 6 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 850 V DC at record local winter lows.

Where Does Sungrow: SG36CX-US {480V} Fall Across Listed CEC Models?

Marks Sungrow: SG36CX-US {480V} (36,046 W AC) across the California Energy Commission inverter AC capacity distribution. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sungrow: SG36CX-US {480V} (36,046 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSungrow: SG36CX-US: 36,046 W

What Dataset Percentiles Define Sungrow: SG36CX-US {480V}?

Benchmarks Sungrow: SG36CX-US {480V} continuous AC output, 97.99% CEC weighted efficiency, and 60 A OCPD breaker demand. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sungrow: SG36CX-US {480V} Technical ThresholdsPercentile comparison for Sungrow: SG36CX-US {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output36,046 WCEC Efficiency97.99%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Sungrow: SG36CX-US {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining Sungrow: SG36CX-US {480V} by Sungrow. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #350 / 2,343

97.99% CEC Weighted Efficiency

-0.03 pts vs the 98.02% 480 V median; overall power rank #509 (36,046 W, top 21.7%; higher than 78.3% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 43.4 A = 54.2 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

550 V - 850 V (Max 850 V DC)

Tracking span of 300.0 V; listed since 2024-09-23 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 36046.0W / 480 V 3-phase -> 43.4 A | Breaker >= 1.25 * 43.4 = 54.2 A -> 60 A

CEC Inverters.csv for Sungrow: SG36CX-US {480V}: Paco=36046.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=97.99%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Sungrow: SG36CX-US {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Sungrow: SG36CX-US {480V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Sungrow: SG36CX-US {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 36,046 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 850 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 550 V - 850 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 51.8112 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.99% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-09-23 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Sungrow: SG36CX-US {480V} (480 V, 3-phase)?

Evaluates Sungrow: SG36CX-US {480V} (60 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Sungrow: SG36CX-US {480V} (60 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 60 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 60 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 60 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 60 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 60 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Sungrow: SG36CX-US {480V}?

Sample PV string lengths aligned within 550-850 V MPPT and 850 V DC max at -10 C. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 550.0-850.0 V MPPT and 850.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 13 to 15 panels 8.85 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 17 to 20 panels 8.8 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 16 to 18 panels 7.65 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 20 panels (fixed) 4.0 kW

Which Competing Grid-Support Inverters Compare to Sungrow: SG36CX-US {480V}?

Competing CEC grid-support inverters near 36,046 W AC and 480 V, 3-phase, led by Canadian Solar Inc: CSI-36KTL-CT {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Canadian Solar Inc: CSI-36KTL-CT {480V}
Canadian Solar Inc
36,000 W -46 W 480.0 V 800.0 V 98.09%
Canadian Solar Inc: CSI-36KTL-GS-FL {480V}
Canadian Solar Inc
36,000 W -46 W 480.0 V 780.0 V 98.05%
Chint Power Systems America: CPS SCA36KTL-DO/US-480 {480V}
Chint Power Systems America
36,000 W -46 W 480.0 V 850.0 V 97.62%
Chint Power Systems America: CPS SCA36KTL-DO/US {480V}
Chint Power Systems America
36,000 W -46 W 480.0 V 800.0 V 98.09%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sungrow: SG36CX-US {480V}?

Check Sungrow: SG36CX-US {480V} (36,046 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on Sungrow: SG36CX-US {480V}.

Sungrow: SG36CX-US {480V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (43.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.99%) and MPPT window (550-850 V) directly against Canadian Solar Inc: CSI-36KTL-CT {480V} (36,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sungrow: SG36CX-US {480V} by Sungrow covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

What breaker and wire size does Sungrow: SG36CX-US {480V} require?

At 36,046 W continuous AC (480 V, 3-phase), continuous current is 43.4 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Sungrow: SG36CX-US {480V} require?

At 36,046 W AC and 480 V, 3-phase, continuous line current is 43.4 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Sungrow: SG36CX-US {480V} compare to Canadian Solar Inc: CSI-36KTL-CT {480V}?

Sungrow: SG36CX-US {480V} delivers 36,046 W AC at 97.99% CEC efficiency with a 850 V DC ceiling, while Canadian Solar Inc: CSI-36KTL-CT {480V} outputs 36,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.