Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Sungrow Power Supply Co Ltd: SG200HX-US {600V} — CEC Inverter Specifications

Manufacturer: Sungrow Power Supply Co Ltd Registry: CEC Verified Engineering Specification

Sungrow Power Supply Co Ltd: SG200HX-US {600V} outputs 200,444 W AC at 600 V, 3-phase (192.9 A continuous, 250 A OCPD), ranking #236 of 2,343 CEC inverters at 98.23% efficiency with a 850-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
200,444 W
AC Voltage
600 V, 3-phase
Min PV Breaker
250 A (parallel Cu feeders)
CEC Efficiency
98.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sungrow Power Supply Co Ltd: SG200HX-US {600V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 600 V, 3-phase grid-support overview for Sungrow Power Supply Co Ltd: SG200HX-US {600V}.

Ranking #246 of 2,343 CEC inverters (top 10.5%; higher than 89.5% of peers), Sungrow Power Supply Co Ltd: SG200HX-US {600V} is a grid-tied PV inverter delivering 200,444 W continuous AC at 600 V, 3-phase (192.9 A continuous). Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.23% (-0.05 pts vs the 98.28% 600 V median) against peers like CSI Solar Co Ltd: CSI-185K-T600GL02-U {600V} (185,005 W).

Where Does Sungrow Power Supply Co Ltd: SG200HX-US {600V} Fall Across Listed CEC Models?

Marks Sungrow Power Supply Co Ltd: SG200HX-US {600V} (200,444 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sungrow Power Supply Co Ltd: SG200HX-US {600V} (200,444 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSungrow Power Supp: 200,444 W

What Dataset Percentiles Define Sungrow Power Supply Co Ltd: SG200HX-US {600V}?

Benchmarks Sungrow Power Supply Co Ltd: SG200HX-US {600V} continuous AC output, 98.23% CEC weighted efficiency, and 250 A OCPD breaker demand.

Sungrow Power Supply Co Ltd: SG200HX-US {600V} Technical ThresholdsPercentile comparison for Sungrow Power Supply Co Ltd: SG200HX-US {600V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output200,444 WCEC Efficiency98.23%Backfeed Breaker250 A

What Do the Dataset Ranks Show for Sungrow Power Supply Co Ltd: SG200HX-US {600V}?

Four key NEC 705.12 and California Energy Commission metrics defining Sungrow Power Supply Co Ltd: SG200HX-US {600V} by Sungrow Power Supply Co Ltd.

Eff #236 / 2,343

98.23% CEC Weighted Efficiency

-0.05 pts vs the 98.28% 600 V median; overall power rank #246 (200,444 W, top 10.5%; higher than 89.5% of peers).

NEC 705.12 Check

250 A Required Backfeed OCPD

125% x 192.9 A = 241.1 A -> 250 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

850 V - 1,300 V (Max 1,300 V DC)

Tracking span of 450.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 200444.0W / 600 V 3-phase -> 192.9 A | Breaker >= 1.25 * 192.9 = 241.1 A -> 250 A

CEC Inverters.csv for Sungrow Power Supply Co Ltd: SG200HX-US {600V}: Paco=200444.0 W, Vac=600 V, Vdcmax=1300.0 V, Eff=98.23%.

Result: Min 250 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Sungrow Power Supply Co Ltd: SG200HX-US {600V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Sungrow Power Supply Co Ltd: SG200HX-US {600V}.

Official California Energy Commission (NREL SAM) test parameters for Sungrow Power Supply Co Ltd: SG200HX-US {600V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 200,444 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 600 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,300 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 850 V - 1,300 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 204.058 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.23% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Sungrow Power Supply Co Ltd: SG200HX-US {600V} (600 V, 3-phase)?

Evaluates Sungrow Power Supply Co Ltd: SG200HX-US {600V} (250 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Sungrow Power Supply Co Ltd: SG200HX-US {600V} (250 A required OCPD at 600 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (600V) 40 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (600V) 80 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (600V) 120 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (600V) 160 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (600V) 240 A 250 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Sungrow Power Supply Co Ltd: SG200HX-US {600V}?

Sample PV string lengths aligned within 850-1,300 V MPPT and 1,300 V DC max at -10 C. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sampled CEC PV modules aligned within 850.0-1300.0 V MPPT and 1300.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 20 to 23 panels 13.57 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 26 to 30 panels 13.2 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 25 to 29 panels 12.32 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 30 to 32 panels 6.4 kW

Which Competing Grid-Support Inverters Compare to Sungrow Power Supply Co Ltd: SG200HX-US {600V}?

Competing CEC grid-support inverters near 200,444 W AC and 600 V, 3-phase, led by CSI Solar Co Ltd: CSI-185K-T600GL02-U {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-185K-T600GL02-U {600V}
CSI Solar Co Ltd
185,005 W -15439 W 600.0 V 1300.0 V 98.3%
CSI Solar Co Ltd: CSI-185K-T600GL03-U {600V}
CSI Solar Co Ltd
185,005 W -15439 W 600.0 V 1300.0 V 98.3%
Ginlong Technologies Co Ltd: Solis-185K-EHV-5G-US {600V}
Ginlong Technologies Co Ltd
185,005 W -15439 W 600.0 V 1300.0 V 98.3%
Yaskawa Solectria Solar: XGI 1500 225-600 {600V}
Yaskawa Solectria Solar
225,000 W +24556 W 600.0 V 1250.0 V 98.26%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sungrow Power Supply Co Ltd: SG200HX-US {600V}?

Check Sungrow Power Supply Co Ltd: SG200HX-US {600V} (200,444 W AC, 250 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on Sungrow Power Supply Co Ltd: SG200HX-US {600V}.

Sungrow Power Supply Co Ltd: SG200HX-US {600V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 250 A OCPD breaker (192.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.23%) and MPPT window (850-1,300 V) directly against CSI Solar Co Ltd: CSI-185K-T600GL02-U {600V} (185,005 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sungrow Power Supply Co Ltd: SG200HX-US {600V} by Sungrow Power Supply Co Ltd covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

What breaker and wire size does Sungrow Power Supply Co Ltd: SG200HX-US {600V} require?

At 200,444 W continuous AC (600 V, 3-phase), continuous current is 192.9 A; 125% NEC 690.8/705.12 sizing requires a 250 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Sungrow Power Supply Co Ltd: SG200HX-US {600V} require?

At 200,444 W AC and 600 V, 3-phase, continuous line current is 192.9 A, requiring a 250 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

How does Sungrow Power Supply Co Ltd: SG200HX-US {600V} compare to CSI Solar Co Ltd: CSI-185K-T600GL02-U {600V}?

Sungrow Power Supply Co Ltd: SG200HX-US {600V} delivers 200,444 W AC at 98.23% CEC efficiency with a 1,300 V DC ceiling, while CSI Solar Co Ltd: CSI-185K-T600GL02-U {600V} outputs 185,005 W at 600 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.