Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Sungrow Power Supply Co Ltd: SC60HV {480V} — CEC Inverter Specifications

Manufacturer: Sungrow Power Supply Co Ltd Registry: CEC Verified Engineering Specification

Sungrow Power Supply Co Ltd: SC60HV {480V} outputs 66,000 W AC at 480 V, 3-phase (79.4 A continuous, 100 A OCPD), ranking #383 of 2,343 CEC inverters at 97.9% efficiency with a 700-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
66,000 W
AC Voltage
480 V, 3-phase
Min PV Breaker
100 A (3 AWG Cu)
CEC Efficiency
97.9%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sungrow Power Supply Co Ltd: SC60HV {480V} Compare Against Peer CEC Listings?

CEC efficiency rank (#383), 700-1,300 V MPPT tracking, and panel fit for Sungrow Power Supply Co Ltd: SC60HV {480V}.

Sungrow Power Supply Co Ltd: SC60HV {480V} from Sungrow Power Supply Co Ltd outputs 79.4 A continuous AC at 480 V, 3-phase (66,000 W AC, rank #377). Paired with 3 AWG Cu conductors and a 100 A OCPD, its 97.9% CEC efficiency compares closely with Canadian Solar Inc: CSI-66KTL-GS {480V} (66,000 W). Keep NEC 690.7 winter string Voc below 1,300 V DC.

Where Does Sungrow Power Supply Co Ltd: SC60HV {480V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Sungrow Power Supply Co Ltd: SC60HV {480V} at 66,000 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sungrow Power Supply Co Ltd: SC60HV {480V} (66,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSungrow Power Supp: 66,000 W

What Dataset Percentiles Define Sungrow Power Supply Co Ltd: SC60HV {480V}?

Dataset percentiles comparing Sungrow Power Supply Co Ltd: SC60HV {480V} against 2,343 certified grid-support inverters nationwide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sungrow Power Supply Co Ltd: SC60HV {480V} Technical ThresholdsPercentile comparison for Sungrow Power Supply Co Ltd: SC60HV {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output66,000 WCEC Efficiency97.9%Backfeed Breaker100 A

What Do the Dataset Ranks Show for Sungrow Power Supply Co Ltd: SC60HV {480V}?

Engineering highlights for Sungrow Power Supply Co Ltd: SC60HV {480V} covering efficiency, 3 AWG Cu feeder, and panel compatibility.

Eff #383 / 2,343

97.9% CEC Weighted Efficiency

-0.12 pts vs the 98.02% 480 V median; overall power rank #377 (66,000 W, top 16.3%; higher than 83.7% of peers).

NEC 705.12 Check

100 A Required Backfeed OCPD

125% x 79.4 A = 99.2 A -> 100 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

700 V - 1,300 V (Max 1,300 V DC)

Tracking span of 600.0 V; listed since 2023-02-13 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 66000.0W / 480 V 3-phase -> 79.4 A | Breaker >= 1.25 * 79.4 = 99.2 A -> 100 A

CEC Inverters.csv for Sungrow Power Supply Co Ltd: SC60HV {480V}: Paco=66000.0 W, Vac=480 V, Vdcmax=1300.0 V, Eff=97.9%.

Result: Min 100 A breaker & 3 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Sungrow Power Supply Co Ltd: SC60HV {480V}?

California Energy Commission Solar Equipment List parameters for Sungrow Power Supply Co Ltd: SC60HV {480V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Sungrow Power Supply Co Ltd: SC60HV {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 66,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,300 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 700 V - 1,300 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 79.3096 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.9% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2023-02-13 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Sungrow Power Supply Co Ltd: SC60HV {480V} (480 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Sungrow Power Supply Co Ltd: SC60HV {480V} (100 A OCPD). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Evaluates Sungrow Power Supply Co Ltd: SC60HV {480V} (100 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 100 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 100 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 100 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 100 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 100 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Sungrow Power Supply Co Ltd: SC60HV {480V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Sungrow Power Supply Co Ltd: SC60HV {480V}.

Sampled CEC PV modules aligned within 700.0-1300.0 V MPPT and 1300.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 17 to 23 panels 13.57 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 21 to 30 panels 13.2 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 21 to 29 panels 12.32 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 25 to 32 panels 6.4 kW

Which Competing Grid-Support Inverters Compare to Sungrow Power Supply Co Ltd: SC60HV {480V}?

Four alternative CEC inverters matched to Sungrow Power Supply Co Ltd: SC60HV {480V} (66,000 W AC), led by Canadian Solar Inc: CSI-66KTL-GS {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Canadian Solar Inc: CSI-66KTL-GS {480V}
Canadian Solar Inc
66,000 W Tie (0 W) 480.0 V 720.0 V 98.39%
CSI Solar Co Ltd: CSI-66KTL-GS-B {480V}
CSI Solar Co Ltd
66,000 W Tie (0 W) 480.0 V 720.0 V 98.39%
Ginlong Technologies Co Ltd: Solis-66K-US-F {480V}
Ginlong Technologies Co Ltd
66,000 W Tie (0 W) 480.0 V 720.0 V 98.39%
Ginlong Technologies Co Ltd: Solis-66K-US-F-SW {480V}
Ginlong Technologies Co Ltd
66,000 W Tie (0 W) 480.0 V 720.0 V 98.39%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sungrow Power Supply Co Ltd: SC60HV {480V}?

Check Sungrow Power Supply Co Ltd: SC60HV {480V} (66,000 W AC, 100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on Sungrow Power Supply Co Ltd: SC60HV {480V}.

Sungrow Power Supply Co Ltd: SC60HV {480V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 100 A OCPD breaker (79.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.9%) and MPPT window (700-1,300 V) directly against Canadian Solar Inc: CSI-66KTL-GS {480V} (66,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sungrow Power Supply Co Ltd: SC60HV {480V} by Sungrow Power Supply Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Sungrow Power Supply Co Ltd: SC60HV {480V} require?

At 66,000 W continuous AC (480 V, 3-phase), continuous current is 79.4 A; 125% NEC 690.8/705.12 sizing requires a 100 A breaker and 3 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Sungrow Power Supply Co Ltd: SC60HV {480V} require?

At 66,000 W AC and 480 V, 3-phase, continuous line current is 79.4 A, requiring a 100 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Sungrow Power Supply Co Ltd: SC60HV {480V} compare to Canadian Solar Inc: CSI-66KTL-GS {480V}?

Sungrow Power Supply Co Ltd: SC60HV {480V} delivers 66,000 W AC at 97.9% CEC efficiency with a 1,300 V DC ceiling, while Canadian Solar Inc: CSI-66KTL-GS {480V} outputs 66,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.