SolarJuice American Inc: S4A-A70 {240V} outputs 6,680 W AC at 240 V (27.8 A continuous, 35 A OCPD), ranking #2,267 of 2,343 CEC inverters at 94.78% efficiency with a 280-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 6,680 W
- AC Voltage
- 240 V
- Min PV Breaker
- 35 A (8 AWG Cu)
- CEC Efficiency
- 94.78%
How Does SolarJuice American Inc: S4A-A70 {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for SolarJuice American Inc: S4A-A70 {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Ranking #1,311 of 2,343 CEC inverters (below CEC median; higher than 44.0% of peers), SolarJuice American Inc: S4A-A70 {240V} is a grid-tied PV inverter delivering 6,680 W continuous AC at 240 V (27.8 A continuous). Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Weighted CEC efficiency reaches 94.78% (-1.90 pts vs the 96.68% 240 V median) against peers like Delta Electronics: SOLIVIA 66 NA G4 TL {240V} (6,600 W).
Where Does SolarJuice American Inc: S4A-A70 {240V} Fall Across Listed CEC Models?
Marks SolarJuice American Inc: S4A-A70 {240V} (6,680 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define SolarJuice American Inc: S4A-A70 {240V}?
Benchmarks SolarJuice American Inc: S4A-A70 {240V} continuous AC output, 94.78% CEC weighted efficiency, and 35 A OCPD breaker demand.
What Do the Dataset Ranks Show for SolarJuice American Inc: S4A-A70 {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining SolarJuice American Inc: S4A-A70 {240V} by SolarJuice American Inc.
94.78% CEC Weighted Efficiency
-1.90 pts vs the 96.68% 240 V median; overall power rank #1,311 (6,680 W, below CEC median; higher than 44.0% of peers).
35 A Required Backfeed OCPD
125% x 27.8 A = 34.8 A -> 35 A standard OCPD using 8 AWG Cu (75 C).
280 V - 500 V (Max 500 V DC)
Tracking span of 220.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 6680.0W / 240 V -> 27.8 A | Breaker >= 1.25 * 27.8 = 34.8 A -> 35 A
CEC Inverters.csv for SolarJuice American Inc: S4A-A70 {240V}: Paco=6680.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=94.78%.
Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for SolarJuice American Inc: S4A-A70 {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SolarJuice American Inc: S4A-A70 {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 6,680 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 280 V - 500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 18.0714 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 94.78% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for SolarJuice American Inc: S4A-A70 {240V}?
Evaluates SolarJuice American Inc: S4A-A70 {240V} (35 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 35 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 35 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 35 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 35 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 35 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With SolarJuice American Inc: S4A-A70 {240V}?
Sample PV string lengths aligned within 280-500 V MPPT and 500 V DC max at -10 C. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 to 11 panels | 4.67 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 10 to 12 panels | 2.4 kW |
Which Competing Grid-Support Inverters Compare to SolarJuice American Inc: S4A-A70 {240V}?
Competing CEC grid-support inverters near 6,680 W AC and 240 V, led by Delta Electronics: SOLIVIA 66 NA G4 TL {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: SOLIVIA 66 NA G4 TL {240V} Delta Electronics |
6,600 W | -80 W | 240.0 V | 500.0 V | 97.62% |
| Delta Electronics: E8-TL-US(AC) {240V} Delta Electronics |
6,494 W | -186 W | 240.0 V | 480.0 V | 98.05% |
| Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V} Afore New Energy Technology (Shanghai) Co Ltd |
6,996 W | +316 W | 240.0 V | 480.0 V | 97.92% |
| Amensolar Ess Co Ltd: N3H-X60-US {240V} Amensolar Ess Co Ltd |
6,117 W | -563 W | 240.0 V | 430.0 V | 97.13% |
What Are the Interconnection Limits and Best-Fit Uses for SolarJuice American Inc: S4A-A70 {240V}?
Check SolarJuice American Inc: S4A-A70 {240V} (6,680 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on SolarJuice American Inc: S4A-A70 {240V}.
SolarJuice American Inc: S4A-A70 {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (27.8 A continuous).
Alternative Inverter Comparison
Compare efficiency (94.78%) and MPPT window (280-500 V) directly against Delta Electronics: SOLIVIA 66 NA G4 TL {240V} (6,600 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SolarJuice American Inc: S4A-A70 {240V} by SolarJuice American Inc covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does SolarJuice American Inc: S4A-A70 {240V} require?
At 6,680 W continuous AC (240 V), continuous current is 27.8 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.
Does SolarJuice American Inc: S4A-A70 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).
How does SolarJuice American Inc: S4A-A70 {240V} compare to Delta Electronics: SOLIVIA 66 NA G4 TL {240V}?
SolarJuice American Inc: S4A-A70 {240V} delivers 6,680 W AC at 94.78% CEC efficiency with a 500 V DC ceiling, while Delta Electronics: SOLIVIA 66 NA G4 TL {240V} outputs 6,600 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)