Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Delta Electronics: SOLIVIA 66 NA G4 TL {240V} — CEC Inverter Specifications

Manufacturer: Delta Electronics Registry: CEC Verified Engineering Specification

Delta Electronics: SOLIVIA 66 NA G4 TL {240V} outputs 6,600 W AC at 240 V (27.5 A continuous, 35 A OCPD), ranking #500 of 2,343 CEC inverters at 97.62% efficiency with a 100-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
6,600 W
AC Voltage
240 V
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
97.62%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Delta Electronics: SOLIVIA 66 NA G4 TL {240V} Compare Against Peer CEC Listings?

How Delta Electronics Delta Electronics: SOLIVIA 66 NA G4 TL {240V} compares on 97.62% efficiency, MPPT span, and 120% busbar interconnection.

Delta Electronics certifies Delta Electronics: SOLIVIA 66 NA G4 TL {240V} (grid-tied PV inverter, listed since 2020-11-12) at 6,600 W AC (824 W above the 5,776 W 240 V median). Its 500 V DC ceiling pairs with an MPPT window of 100-500 V (span 400.0 V). Under NEC 690.8/705.12, 125% sizing demands 8 AWG Cu conductors on a 35 A OCPD.

Where Does Delta Electronics: SOLIVIA 66 NA G4 TL {240V} Fall Across Listed CEC Models?

Position of Delta Electronics: SOLIVIA 66 NA G4 TL {240V} (6,600 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Delta Electronics: SOLIVIA 66 NA G4 TL {240V} (6,600 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDelta Electronics:: 6,600 W

What Dataset Percentiles Define Delta Electronics: SOLIVIA 66 NA G4 TL {240V}?

Percentile placement of Delta Electronics: SOLIVIA 66 NA G4 TL {240V} across AC power class, conversion efficiency, and backfeed breaker size.

Delta Electronics: SOLIVIA 66 NA G4 TL {240V} Technical ThresholdsPercentile comparison for Delta Electronics: SOLIVIA 66 NA G4 TL {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output6,600 WCEC Efficiency97.62%Backfeed Breaker35 A

What Do the Dataset Ranks Show for Delta Electronics: SOLIVIA 66 NA G4 TL {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Delta Electronics: SOLIVIA 66 NA G4 TL {240V}.

Eff #500 / 2,343

97.62% CEC Weighted Efficiency

+0.94 pts vs the 96.68% 240 V median; overall power rank #1,332 (6,600 W, below CEC median; higher than 43.1% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 27.5 A = 34.4 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

100 V - 500 V (Max 500 V DC)

Tracking span of 400.0 V; listed since 2020-11-12 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 6600.0W / 240 V -> 27.5 A | Breaker >= 1.25 * 27.5 = 34.4 A -> 35 A

CEC Inverters.csv for Delta Electronics: SOLIVIA 66 NA G4 TL {240V}: Paco=6600.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=97.62%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Delta Electronics: SOLIVIA 66 NA G4 TL {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Delta Electronics: SOLIVIA 66 NA G4 TL {240V}.

Official California Energy Commission (NREL SAM) test parameters for Delta Electronics: SOLIVIA 66 NA G4 TL {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 6,600 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 100 V - 500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 17.7926 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.62% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-11-12 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Delta Electronics: SOLIVIA 66 NA G4 TL {240V}?

Check whether Delta Electronics: SOLIVIA 66 NA G4 TL {240V} (35 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Delta Electronics: SOLIVIA 66 NA G4 TL {240V} (35 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 35 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 35 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 35 A PASS (120% Rule)
200A Bus / 175A Main 65 A 35 A PASS (120% Rule)
225A Bus / 200A Main 70 A 35 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Delta Electronics: SOLIVIA 66 NA G4 TL {240V}?

Verified cold-weather (-10 C) series module counts matched to Delta Electronics: SOLIVIA 66 NA G4 TL {240V}'s 500 V DC ceiling.

Sampled CEC PV modules aligned within 100.0-500.0 V MPPT and 500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 3 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 3 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 3 to 11 panels 4.67 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 4 to 12 panels 2.4 kW

Which Competing Grid-Support Inverters Compare to Delta Electronics: SOLIVIA 66 NA G4 TL {240V}?

Alternative CEC inverters comparable to Delta Electronics: SOLIVIA 66 NA G4 TL {240V}, including Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V} (6,996 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
6,996 W +396 W 240.0 V 480.0 V 97.92%
Amensolar Ess Co Ltd: N3H-X60-US {240V}
Amensolar Ess Co Ltd
6,117 W -483 W 240.0 V 430.0 V 97.13%
Anker Innovations Limited: X1-P6K-US {240V}
Anker Innovations Limited
6,040 W -560 W 240.0 V 450.0 V 97.43%
Dyness Digital Energy Technology Co LTD: TX6K-AM {240V}
Dyness Digital Energy Technology Co LTD
6,028 W -572 W 240.0 V 490.0 V 96.68%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: SOLIVIA 66 NA G4 TL {240V}?

Check Delta Electronics: SOLIVIA 66 NA G4 TL {240V} (6,600 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on Delta Electronics: SOLIVIA 66 NA G4 TL {240V}.

Delta Electronics: SOLIVIA 66 NA G4 TL {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (27.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.62%) and MPPT window (100-500 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V} (6,996 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Delta Electronics: SOLIVIA 66 NA G4 TL {240V} by Delta Electronics covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Delta Electronics: SOLIVIA 66 NA G4 TL {240V} require?

At 6,600 W continuous AC (240 V), continuous current is 27.5 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

Does Delta Electronics: SOLIVIA 66 NA G4 TL {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).

How does Delta Electronics: SOLIVIA 66 NA G4 TL {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V}?

Delta Electronics: SOLIVIA 66 NA G4 TL {240V} delivers 6,600 W AC at 97.62% CEC efficiency with a 500 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V} outputs 6,996 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.