Sol-Ark: Sol-Ark-12K-P {240V} — CEC Inverter Specifications

Manufacturer: Sol-Ark Registry: CEC Verified Engineering Specification

Sol-Ark: Sol-Ark-12K-P {240V} outputs 8,982 W AC at 240 V (37.4 A continuous, 50 A OCPD), ranking #918 of 2,343 CEC inverters at 97.07% efficiency with a 240-425 V MPPT window and 425 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
8,982 W
AC Voltage
240 V
Min PV Breaker
50 A (8 AWG Cu)
CEC Efficiency
97.07%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sol-Ark: Sol-Ark-12K-P {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Sol-Ark: Sol-Ark-12K-P {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Ranking #1,027 of 2,343 CEC inverters (top 43.9%; higher than 56.1% of peers), Sol-Ark: Sol-Ark-12K-P {240V} is a hybrid battery-capable inverter delivering 8,982 W continuous AC at 240 V (37.4 A continuous). Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Weighted CEC efficiency reaches 97.07% (+0.39 pts vs the 96.68% 240 V median) against peers like Base Power Inc: MIN 9000TL-XH-US {240V} (9,063 W).

Where Does Sol-Ark: Sol-Ark-12K-P {240V} Fall Across Listed CEC Models?

Marks Sol-Ark: Sol-Ark-12K-P {240V} (8,982 W AC) across the California Energy Commission inverter AC capacity distribution. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sol-Ark: Sol-Ark-12K-P {240V} (8,982 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSol-Ark: Sol-Ark-1: 8,982 W

What Dataset Percentiles Define Sol-Ark: Sol-Ark-12K-P {240V}?

Benchmarks Sol-Ark: Sol-Ark-12K-P {240V} continuous AC output, 97.07% CEC weighted efficiency, and 50 A OCPD breaker demand. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sol-Ark: Sol-Ark-12K-P {240V} Technical ThresholdsPercentile comparison for Sol-Ark: Sol-Ark-12K-P {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output8,982 WCEC Efficiency97.07%Backfeed Breaker50 A

What Do the Dataset Ranks Show for Sol-Ark: Sol-Ark-12K-P {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Sol-Ark: Sol-Ark-12K-P {240V} by Sol-Ark. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Eff #918 / 2,343

97.07% CEC Weighted Efficiency

+0.39 pts vs the 96.68% 240 V median; overall power rank #1,027 (8,982 W, top 43.9%; higher than 56.1% of peers).

NEC 705.12 Check

50 A Required Backfeed OCPD

125% x 37.4 A = 46.8 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

240 V - 425 V (Max 425 V DC)

Tracking span of 185.0 V; listed since 2023-04-11 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 8982.0W / 240 V -> 37.4 A | Breaker >= 1.25 * 37.4 = 46.8 A -> 50 A

CEC Inverters.csv for Sol-Ark: Sol-Ark-12K-P {240V}: Paco=8982.0 W, Vac=240 V, Vdcmax=425.0 V, Eff=97.07%.

Result: Min 50 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Sol-Ark: Sol-Ark-12K-P {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Sol-Ark: Sol-Ark-12K-P {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Sol-Ark: Sol-Ark-12K-P {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 8,982 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 425 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 240 V - 425 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 25.0075 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.07% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2023-04-11 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Sol-Ark: Sol-Ark-12K-P {240V}?

Evaluates Sol-Ark: Sol-Ark-12K-P {240V} (50 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Sol-Ark: Sol-Ark-12K-P {240V} (50 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 50 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 50 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 50 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 50 A PASS (120% Rule)
225A Bus / 200A Main 70 A 50 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Sol-Ark: Sol-Ark-12K-P {240V}?

Sample PV string lengths aligned within 240-425 V MPPT and 425 V DC max at -10 C. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 240.0-425.0 V MPPT and 425.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 7 panels 4.13 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 7 to 9 panels 3.83 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 10 panels 2.0 kW

Which Competing Grid-Support Inverters Compare to Sol-Ark: Sol-Ark-12K-P {240V}?

Competing CEC grid-support inverters near 8,982 W AC and 240 V, led by Base Power Inc: MIN 9000TL-XH-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Base Power Inc: MIN 9000TL-XH-US {240V}
Base Power Inc
9,063 W +81 W 240.0 V 480.0 V 97.69%
ABB: UNO-86-TL-OUTD-S-US-A {240V}
ABB
8,600 W -382 W 240.0 V 480.0 V 97.03%
ABB: UNO-86-TL-OUTD-S-US-Z-A {240V}
ABB
8,600 W -382 W 240.0 V 480.0 V 97.03%
ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V}
ABB
8,600 W -382 W 240.0 V 480.0 V 97.03%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sol-Ark: Sol-Ark-12K-P {240V}?

Check Sol-Ark: Sol-Ark-12K-P {240V} (8,982 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 425 V DC on Sol-Ark: Sol-Ark-12K-P {240V}.

Sol-Ark: Sol-Ark-12K-P {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (37.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.07%) and MPPT window (240-425 V) directly against Base Power Inc: MIN 9000TL-XH-US {240V} (9,063 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sol-Ark: Sol-Ark-12K-P {240V} by Sol-Ark covering breaker sizing, MPPT limits, and 240 V interconnection. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

What breaker and wire size does Sol-Ark: Sol-Ark-12K-P {240V} require?

At 8,982 W continuous AC (240 V), continuous current is 37.4 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

Does Sol-Ark: Sol-Ark-12K-P {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 50 A at 240 V means Needs Derate / Tap 705.11.

How does Sol-Ark: Sol-Ark-12K-P {240V} compare to Base Power Inc: MIN 9000TL-XH-US {240V}?

Sol-Ark: Sol-Ark-12K-P {240V} delivers 8,982 W AC at 97.07% CEC efficiency with a 425 V DC ceiling, while Base Power Inc: MIN 9000TL-XH-US {240V} outputs 9,063 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.