Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Sol-Ark: Limitless 15K-LV {208V} — CEC Inverter Specifications

Manufacturer: Sol-Ark Registry: CEC Verified Engineering Specification

Sol-Ark: Limitless 15K-LV {208V} outputs 13,010 W AC at 208 V, 3-phase (36.1 A continuous, 50 A OCPD), ranking #1,776 of 2,343 CEC inverters at 96.29% efficiency with a 200-425 V MPPT window and 425 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
13,010 W
AC Voltage
208 V, 3-phase
Min PV Breaker
50 A (8 AWG Cu)
CEC Efficiency
96.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sol-Ark: Limitless 15K-LV {208V} Compare Against Peer CEC Listings?

Breaker sizing (50 A), 8 AWG Cu wire rules, and DC input limits for Sol-Ark: Limitless 15K-LV {208V}.

Classified as a hybrid battery-capable inverter (listed since 2023-02-13), Sol-Ark: Limitless 15K-LV {208V} requires 45.1 A design capacity -> 50 A breaker using 8 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.29% (-0.53 pts vs overall CEC median) across 2,343 CEC models, while commercial 208 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (208v) or nec 705.11 supply-side tap.

Where Does Sol-Ark: Limitless 15K-LV {208V} Fall Across Listed CEC Models?

Output power comparison showing where Sol-Ark: Limitless 15K-LV {208V} sits among all 2,343 CEC-listed grid-support inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sol-Ark: Limitless 15K-LV {208V} (13,010 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSol-Ark: Limitless: 13,010 W

What Dataset Percentiles Define Sol-Ark: Limitless 15K-LV {208V}?

Relative ranking of Sol-Ark: Limitless 15K-LV {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Sol-Ark: Limitless 15K-LV {208V} Technical ThresholdsPercentile comparison for Sol-Ark: Limitless 15K-LV {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output13,010 WCEC Efficiency96.29%Backfeed Breaker50 A

What Do the Dataset Ranks Show for Sol-Ark: Limitless 15K-LV {208V}?

Snapshot of Sol-Ark: Limitless 15K-LV {208V} efficiency rank (#1,776), OCPD breaker size, MPPT span, and busbar verdict. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Eff #1,776 / 2,343

96.29% CEC Weighted Efficiency

-0.12 pts vs the 96.41% 208 V median; overall power rank #692 (13,010 W, top 29.6%; higher than 70.4% of peers).

NEC 705.12 Check

50 A Required Backfeed OCPD

125% x 36.1 A = 45.1 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

200 V - 425 V (Max 425 V DC)

Tracking span of 225.0 V; listed since 2023-02-13 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, 3-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 13010.0W / 208 V 3-phase -> 36.1 A | Breaker >= 1.25 * 36.1 = 45.1 A -> 50 A

CEC Inverters.csv for Sol-Ark: Limitless 15K-LV {208V}: Paco=13010.0 W, Vac=208 V, Vdcmax=425.0 V, Eff=96.29%.

Result: Min 50 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Sol-Ark: Limitless 15K-LV {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Sol-Ark: Limitless 15K-LV {208V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Sol-Ark: Limitless 15K-LV {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 13,010 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 425 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 425 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 42.223 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.29% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2023-02-13 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

What Switchgear Limits Apply to Sol-Ark: Limitless 15K-LV {208V} (208 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Sol-Ark: Limitless 15K-LV {208V} at 208 V, 3-phase. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Evaluates Sol-Ark: Limitless 15K-LV {208V} (50 A required OCPD at 208 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 50 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 50 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 50 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 50 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 50 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Sol-Ark: Limitless 15K-LV {208V}?

Minimum and maximum series solar module strings fitting Sol-Ark: Limitless 15K-LV {208V} MPPT and 425 V limits. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 200.0-425.0 V MPPT and 425.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 7 panels 4.13 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 9 panels 3.83 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 10 panels 2.0 kW

Which Competing Grid-Support Inverters Compare to Sol-Ark: Limitless 15K-LV {208V}?

Peer 208 V, 3-phase CEC inverters near 13,010 W AC output such as EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}
EG4 Electronics LLC
13,899 W +889 W 208.0 V 440.0 V 96.46%
Chint Power Systems America: CPS ECH12KTL/US {208V}
Chint Power Systems America
12,000 W -1010 W 208.0 V 480.0 V 96.63%
EcoFlow Inc: EF-PCS-24 {208V 115kW}
EcoFlow Inc
11,444 W -1566 W 208.0 V 480.0 V 96.52%
Chint Power Systems America: CPS ECH114KTL/US {208V}
Chint Power Systems America
11,350 W -1660 W 208.0 V 480.0 V 96.63%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sol-Ark: Limitless 15K-LV {208V}?

Check Sol-Ark: Limitless 15K-LV {208V} (13,010 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 425 V DC on Sol-Ark: Limitless 15K-LV {208V}.

Sol-Ark: Limitless 15K-LV {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (36.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.29%) and MPPT window (200-425 V) directly against EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} (13,899 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sol-Ark: Limitless 15K-LV {208V} by Sol-Ark covering breaker sizing, MPPT limits, and 208 V, 3-phase interconnection.

What breaker and wire size does Sol-Ark: Limitless 15K-LV {208V} require?

At 13,010 W continuous AC (208 V, 3-phase), continuous current is 36.1 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Sol-Ark: Limitless 15K-LV {208V} require?

At 13,010 W AC and 208 V, 3-phase, continuous line current is 36.1 A, requiring a 50 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Sol-Ark: Limitless 15K-LV {208V} compare to EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V}?

Sol-Ark: Limitless 15K-LV {208V} delivers 13,010 W AC at 96.29% CEC efficiency with a 425 V DC ceiling, while EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V} outputs 13,899 W at 208 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.