Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} — CEC Inverter Specifications

Manufacturer: Shenzhen SOSEN Innovation Technology CoLtd Registry: CEC Verified Engineering Specification

Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} outputs 15,015 W AC at 240 V (62.6 A continuous, 80 A OCPD), ranking #1,798 of 2,343 CEC inverters at 96.27% efficiency with a 202-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
15,015 W
AC Voltage
240 V
Min PV Breaker
80 A (4 AWG Cu)
CEC Efficiency
96.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}.

Ranking #668 of 2,343 CEC inverters (top 28.6%; higher than 71.4% of peers), Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} is a hybrid battery-capable inverter delivering 15,015 W continuous AC at 240 V (62.6 A continuous). Its 80 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Weighted CEC efficiency reaches 96.27% (-0.41 pts vs the 96.68% 240 V median) against peers like Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W).

Where Does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} Fall Across Listed CEC Models?

Marks Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} (15,015 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} (15,015 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen SOSEN Inn: 15,015 W

What Dataset Percentiles Define Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}?

Benchmarks Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} continuous AC output, 96.27% CEC weighted efficiency, and 80 A OCPD breaker demand.

Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} Technical ThresholdsPercentile comparison for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output15,015 WCEC Efficiency96.27%Backfeed Breaker80 A

What Do the Dataset Ranks Show for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} by Shenzhen SOSEN Innovation Technology CoLtd.

Eff #1,798 / 2,343

96.27% CEC Weighted Efficiency

-0.41 pts vs the 96.68% 240 V median; overall power rank #668 (15,015 W, top 28.6%; higher than 71.4% of peers).

NEC 705.12 Check

80 A Required Backfeed OCPD

125% x 62.6 A = 78.2 A -> 80 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

202 V - 480 V (Max 480 V DC)

Tracking span of 278.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 15014.8W / 240 V -> 62.6 A | Breaker >= 1.25 * 62.6 = 78.2 A -> 80 A

CEC Inverters.csv for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}: Paco=15014.8 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.27%.

Result: Min 80 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 15,015 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 202 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 41.0434 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.27% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}?

Evaluates Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} (80 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} (80 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 80 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 80 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 80 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 80 A Needs Derate / Tap 705.11
225A Bus / 200A Main 70 A 80 A Needs Derate / Tap 705.11

Which CEC PV Module Strings Pair With Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}?

Sample PV string lengths aligned within 202-480 V MPPT and 480 V DC max at -10 C. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sampled CEC PV modules aligned within 202.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 7 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}?

Competing CEC grid-support inverters near 15,015 W AC and 240 V, led by Amensolar Ess Co Ltd: N3H-X16US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X16US {240V}
Amensolar Ess Co Ltd
16,199 W +1184 W 240.0 V 430.0 V 96.25%
Amensolar Ess Co Ltd: N3H-X12US {240V}
Amensolar Ess Co Ltd
12,214 W -2801 W 240.0 V 430.0 V 96.17%
Chint Power Systems America: CPS ECH12KTL/US {240V}
Chint Power Systems America
11,990 W -3025 W 240.0 V 480.0 V 96.59%
Delta Electronics: S12_BDI {240V}
Delta Electronics
11,589 W -3426 W 240.0 V 480.0 V 96.99%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}?

Check Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} (15,015 W AC, 80 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 80 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V}.

Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on an 80 A OCPD breaker (62.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.27%) and MPPT window (202-480 V) directly against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} by Shenzhen SOSEN Innovation Technology CoLtd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} require?

At 15,015 W continuous AC (240 V), continuous current is 62.6 A; 125% NEC 690.8/705.12 sizing requires an 80 A breaker and 4 AWG Cu (75 C) wire.

Does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 80 A at 240 V means Needs Derate / Tap 705.11.

How does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} compare to Amensolar Ess Co Ltd: N3H-X16US {240V}?

Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V} delivers 15,015 W AC at 96.27% CEC efficiency with a 480 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X16US {240V} outputs 16,199 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.