Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} outputs 10,011 W AC at 240 V (41.7 A continuous, 60 A OCPD), ranking #1,348 of 2,343 CEC inverters at 96.61% efficiency with a 135-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 10,011 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 96.61%
How Does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,348), 135-480 V MPPT tracking, and panel fit for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}.
Operating at 240 V, Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} converts DC array energy at 96.61% CEC weighted efficiency (below overall CEC median; higher than 40.1% of peers) with a 480 V max DC input and 27.2703 A max input current for NEC 690.7 string safety. Compare this 10,011 W hybrid battery-capable inverter directly with Base Power Inc: MIN 10000TL-XH-US {240V} (10,082 W). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
Where Does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} at 10,011 W continuous AC output.
What Dataset Percentiles Define Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}?
Dataset percentiles comparing Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}?
Engineering highlights for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.
96.61% CEC Weighted Efficiency
-0.07 pts vs the 96.68% 240 V median; overall power rank #887 (10,011 W, top 38.0%; higher than 62.0% of peers).
60 A Required Backfeed OCPD
125% x 41.7 A = 52.1 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
135 V - 480 V (Max 480 V DC)
Tracking span of 345.0 V; active in CEC directory (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 10010.9W / 240 V -> 41.7 A | Breaker >= 1.25 * 41.7 = 52.1 A -> 60 A
CEC Inverters.csv for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}: Paco=10010.9 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.61%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}?
California Energy Commission Solar Equipment List parameters for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} (hybrid battery-capable inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 10,011 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 135 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 27.2703 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.61% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}?
Panelboard and switchgear backfeed allowances for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} (60 A OCPD). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 4 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 5 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 4 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 5 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}?
Four alternative CEC inverters matched to Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} (10,011 W AC), led by Base Power Inc: MIN 10000TL-XH-US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Base Power Inc: MIN 10000TL-XH-US {240V} Base Power Inc |
10,082 W | +71 W | 240.0 V | 480.0 V | 97.61% |
| Amensolar Ess Co Ltd: N3H-X100-US {240V} Amensolar Ess Co Ltd |
10,177 W | +166 W | 240.0 V | 430.0 V | 97.15% |
| Amensolar Ess Co Ltd: N3H-X10US {240V} Amensolar Ess Co Ltd |
10,177 W | +166 W | 240.0 V | 430.0 V | 97.15% |
| Delta Electronics: E10_BDI {240V} Delta Electronics |
9,674 W | -337 W | 240.0 V | 480.0 V | 97.21% |
What Are the Interconnection Limits and Best-Fit Uses for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}?
Check Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} (10,011 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V}.
Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (41.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.61%) and MPPT window (135-480 V) directly against Base Power Inc: MIN 10000TL-XH-US {240V} (10,082 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} by Shenzhen SOSEN Innovation Technology CoLtd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} require?
At 10,011 W continuous AC (240 V), continuous current is 41.7 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} compare to Base Power Inc: MIN 10000TL-XH-US {240V}?
Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V} delivers 10,011 W AC at 96.61% CEC efficiency with a 480 V DC ceiling, while Base Power Inc: MIN 10000TL-XH-US {240V} outputs 10,082 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)