Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} — CEC Inverter Specifications

Manufacturer: Shenzhen Sinexcel Electric Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} outputs 29,907 W AC at 480 V, 3-phase (36.0 A continuous, 45 A OCPD), ranking #1,916 of 2,343 CEC inverters at 96.08% efficiency with a 355-750 V MPPT window and 750 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
29,907 W
AC Voltage
480 V, 3-phase
Min PV Breaker
45 A (8 AWG Cu)
CEC Efficiency
96.08%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,916), 355-750 V MPPT tracking, and panel fit for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}.

Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} from Shenzhen Sinexcel Electric Co Ltd outputs 36.0 A continuous AC at 480 V, 3-phase (29,907 W AC, rank #565). Paired with 8 AWG Cu conductors and a 45 A OCPD, its 96.08% CEC efficiency compares closely with Fortress Power LLC: FP-Nano-30k-N {480V} (29,885 W). Keep NEC 690.7 winter string Voc below 750 V DC.

Where Does Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} at 29,907 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} (29,907 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Sinexcel : 29,907 W

What Dataset Percentiles Define Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}?

Dataset percentiles comparing Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} against 2,343 certified grid-support inverters nationwide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} Technical ThresholdsPercentile comparison for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output29,907 WCEC Efficiency96.08%Backfeed Breaker45 A

What Do the Dataset Ranks Show for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}?

Engineering highlights for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} covering efficiency, 8 AWG Cu feeder, and panel compatibility.

Eff #1,916 / 2,343

96.08% CEC Weighted Efficiency

-1.94 pts vs the 98.02% 480 V median; overall power rank #565 (29,907 W, top 24.1%; higher than 75.9% of peers).

NEC 705.12 Check

45 A Required Backfeed OCPD

125% x 36.0 A = 45.0 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

355 V - 750 V (Max 750 V DC)

Tracking span of 395.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 29907.0W / 480 V 3-phase -> 36.0 A | Breaker >= 1.25 * 36.0 = 45.0 A -> 45 A

CEC Inverters.csv for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}: Paco=29907.0 W, Vac=480 V, Vdcmax=750.0 V, Eff=96.08%.

Result: Min 45 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}?

California Energy Commission Solar Equipment List parameters for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 29,907 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 750 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 355 V - 750 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 51.8803 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.08% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} (480 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} (45 A OCPD). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} (45 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 45 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 45 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 45 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 45 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 45 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}.

Sampled CEC PV modules aligned within 355.0-750.0 V MPPT and 750.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 9 to 13 panels 7.67 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 11 to 17 panels 7.48 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 11 to 16 panels 6.8 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 13 to 18 panels 3.6 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}?

Four alternative CEC inverters matched to Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} (29,907 W AC), led by Fortress Power LLC: FP-Nano-30k-N {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Fortress Power LLC: FP-Nano-30k-N {480V}
Fortress Power LLC
29,885 W -22 W 480.0 V 850.0 V 97.44%
CSI Solar Co Ltd: CSI-30K-T480GL03-U {480V}
CSI Solar Co Ltd
29,883 W -24 W 480.0 V 850.0 V 98.28%
CSI Solar Co Ltd: CSI-30K-T480GL01-UB {480V}
CSI Solar Co Ltd
29,948 W +41 W 480.0 V 800.0 V 98.34%
CE+T America Inc: 30C {480V}
CE+T America Inc
29,990 W +83 W 480.0 V 850.0 V 95.24%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}?

Check Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} (29,907 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 750 V DC on Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V}.

Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (36.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.08%) and MPPT window (355-750 V) directly against Fortress Power LLC: FP-Nano-30k-N {480V} (29,885 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} by Shenzhen Sinexcel Electric Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} require?

At 29,907 W continuous AC (480 V, 3-phase), continuous current is 36.0 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} require?

At 29,907 W AC and 480 V, 3-phase, continuous line current is 36.0 A, requiring a 45 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} compare to Fortress Power LLC: FP-Nano-30k-N {480V}?

Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V} delivers 29,907 W AC at 96.08% CEC efficiency with a 750 V DC ceiling, while Fortress Power LLC: FP-Nano-30k-N {480V} outputs 29,885 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.