Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} — CEC Inverter Specifications

Manufacturer: Shenzhen Sinexcel Electric Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} outputs 498,340 W AC at 400 V, 3-phase (719.3 A continuous, 900 A OCPD), ranking #1,892 of 2,343 CEC inverters at 96.11% efficiency with a 640-900 V MPPT window and 900 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
498,340 W
AC Voltage
400 V, 3-phase
Min PV Breaker
900 A (parallel Cu feeders)
CEC Efficiency
96.11%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,892), 640-900 V MPPT tracking, and panel fit for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}.

Operating at 400 V, 3-phase, Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} converts DC array energy at 96.11% CEC weighted efficiency (below overall CEC median; higher than 18.6% of peers) with a 900 V max DC input and 691.312 A max input current for NEC 690.7 string safety. Compare this 498,340 W grid-tied PV inverter directly with EPC Power Corp: 50-200100 {720V} (561,806 W). Commercial 400 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (400V) or NEC 705.11 supply-side tap.

Where Does Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} at 498,340 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} (498,340 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Sinexcel : 498,340 W

What Dataset Percentiles Define Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}?

Dataset percentiles comparing Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} against 2,343 certified grid-support inverters nationwide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} Technical ThresholdsPercentile comparison for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output498,340 WCEC Efficiency96.11%Backfeed Breaker900 A

What Do the Dataset Ranks Show for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}?

Engineering highlights for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.

Eff #1,892 / 2,343

96.11% CEC Weighted Efficiency

-0.70 pts vs the 96.81% 400 V median; overall power rank #200 (498,340 W, top 8.6%; higher than 91.4% of peers).

NEC 705.12 Check

900 A Required Backfeed OCPD

125% x 719.3 A = 899.1 A -> 900 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

640 V - 900 V (Max 900 V DC)

Tracking span of 260.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 400 V, 3-phase switchgear (200A Bus / 200A Main (400V) to 1,200A Bus / 1,200A Main (400V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 498340.0W / 400 V 3-phase -> 719.3 A | Breaker >= 1.25 * 719.3 = 899.1 A -> 900 A

CEC Inverters.csv for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}: Paco=498340.0 W, Vac=400 V, Vdcmax=900.0 V, Eff=96.11%.

Result: Min 900 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (400V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}?

California Energy Commission Solar Equipment List parameters for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 498,340 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 400 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 900 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 640 V - 900 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 691.312 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.11% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} (400 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} (900 A OCPD). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} (900 A required OCPD at 400 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (400V) 40 A 900 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (400V) 80 A 900 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (400V) 120 A 900 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (400V) 160 A 900 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (400V) 240 A 900 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}.

Sampled CEC PV modules aligned within 640.0-900.0 V MPPT and 900.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 15 to 16 panels 9.44 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 20 to 21 panels 9.24 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 19 to 20 panels 8.5 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 16 panels (fixed) 8.24 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}?

Four alternative CEC inverters matched to Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} (498,340 W AC), led by EPC Power Corp: 50-200100 {720V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EPC Power Corp: 50-200100 {720V}
EPC Power Corp
561,806 W +63466 W 720.0 V 1500.0 V 98.58%
ABB: PVS-175-TL-POWER-MODULE-1-US {800V}
ABB
179,574 W -318766 W 800.0 V 1200.0 V 97.39%
LS Energy Solutions LLC: PBE-6140-R61-1A0-1000 {600V}
LS Energy Solutions LLC
139,449 W -358891 W 600.0 V 1350.0 V 98.27%
JingTsing Technology Ltd: JTES-PCS125K-1000/480-L03C1 {480V}
JingTsing Technology Ltd
127,819 W -370521 W 480.0 V 950.0 V 98.0%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}?

Check Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} (498,340 W AC, 900 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 400 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (400V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 900 V DC on Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V}.

Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 900 A OCPD breaker (719.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.11%) and MPPT window (640-900 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} by Shenzhen Sinexcel Electric Co Ltd covering breaker sizing, MPPT limits, and 400 V, 3-phase interconnection.

What breaker and wire size does Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} require?

At 498,340 W continuous AC (400 V, 3-phase), continuous current is 719.3 A; 125% NEC 690.8/705.12 sizing requires a 900 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} require?

At 498,340 W AC and 400 V, 3-phase, continuous line current is 719.3 A, requiring a 900 A OCPD and 1,200A Bus / 1,200A Main (400V) or NEC 705.11 interconnection.

How does Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} compare to EPC Power Corp: 50-200100 {720V}?

Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V} delivers 498,340 W AC at 96.11% CEC efficiency with a 900 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 400 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.