Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} outputs 5,040 W AC at 240 V (21.0 A continuous, 30 A OCPD), ranking #1,019 of 2,343 CEC inverters at 96.99% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 5,040 W
- AC Voltage
- 240 V
- Min PV Breaker
- 30 A (10 AWG Cu)
- CEC Efficiency
- 96.99%
How Does Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} Compare Against Peer CEC Listings?
How Shenzhen Senergy Technology Co Ltd Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} compares on 96.99% efficiency, MPPT span, and 120% busbar interconnection.
With a 200-480 V MPPT tracking band and 480 V DC ceiling, Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} handles 5,040 W continuous AC (736 W below the 5,776 W 240 V median). Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Installers comparing Shenzhen Senergy Technology Co Ltd against Dyness Digital Energy Technology Co LTD: TX5K-HM {240V} (5,020 W) should verify whether listed since 2025-04-01 grid-support firmware meets local IEEE 1547 utility rules.
Where Does Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} Fall Across Listed CEC Models?
Position of Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} (5,040 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}?
Percentile placement of Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}.
96.99% CEC Weighted Efficiency
+0.31 pts vs the 96.68% 240 V median; overall power rank #1,488 (5,040 W, below CEC median; higher than 36.4% of peers).
30 A Required Backfeed OCPD
125% x 21.0 A = 26.2 A -> 30 A standard OCPD using 10 AWG Cu (75 C).
200 V - 480 V (Max 480 V DC)
Tracking span of 280.0 V; listed since 2025-04-01 (hybrid battery-capable inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 5040.0W / 240 V -> 21.0 A | Breaker >= 1.25 * 21.0 = 26.2 A -> 30 A
CEC Inverters.csv for Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}: Paco=5040.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.99%.
Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 5,040 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 200 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 14.4344 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.99% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-04-01 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}?
Check whether Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} (30 A breaker) fits without main breaker derate or supply-side taps.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 30 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 30 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 30 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 30 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 30 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}?
Verified cold-weather (-10 C) series module counts matched to Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}'s 480 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}?
Alternative CEC inverters comparable to Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}, including Dyness Digital Energy Technology Co LTD: TX5K-HM {240V} (5,020 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Dyness Digital Energy Technology Co LTD: TX5K-HM {240V} Dyness Digital Energy Technology Co LTD |
5,020 W | -20 W | 240.0 V | 500.0 V | 97.05% |
| Altenergy Power System Inc: ELS-5K {240V} Altenergy Power System Inc |
5,008 W | -32 W | 240.0 V | 60.0 V | 93.21% |
| Darfon Electronics Corp: H5000xxxxxx {240V} Darfon Electronics Corp |
5,074 W | +34 W | 240.0 V | 380.0 V | 95.84% |
| ABB: PVI-5000-OUTD-US-A {240V} ABB |
5,000 W | -40 W | 240.0 V | 480.0 V | 96.33% |
What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}?
Check Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} (5,040 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V}.
Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} Panel & Wire Spec
Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (21.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.99%) and MPPT window (200-480 V) directly against Dyness Digital Energy Technology Co LTD: TX5K-HM {240V} (5,020 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} by Shenzhen Senergy Technology Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} require?
At 5,040 W continuous AC (240 V), continuous current is 21.0 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.
Does Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).
How does Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} compare to Dyness Digital Energy Technology Co LTD: TX5K-HM {240V}?
Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V} delivers 5,040 W AC at 96.99% CEC efficiency with a 480 V DC ceiling, while Dyness Digital Energy Technology Co LTD: TX5K-HM {240V} outputs 5,020 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)