Manufacturer: Shenzhen Senergy Technology Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} outputs 11,567 W AC at 240 V (48.2 A continuous, 70 A OCPD), ranking #1,467 of 2,343 CEC inverters at 96.56% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
11,567 W
AC Voltage
240 V
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
96.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}.

Rated at 11,567 W AC (48.2 A continuous), Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} ranks #1,467 of 2,343 CEC units at 96.56% efficiency (-0.12 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 70 A circuit is 4 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 480 V DC at record local winter lows.

Where Does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} Fall Across Listed CEC Models?

Marks Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} (11,567 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} (11,567 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Senergy T: 11,567 W

What Dataset Percentiles Define Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Benchmarks Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} continuous AC output, 96.56% CEC weighted efficiency, and 70 A OCPD breaker demand.

Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} Technical ThresholdsPercentile comparison for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output11,567 WCEC Efficiency96.56%Backfeed Breaker70 A

What Do the Dataset Ranks Show for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} by Shenzhen Senergy Technology Co Ltd.

Eff #1,467 / 2,343

96.56% CEC Weighted Efficiency

-0.12 pts vs the 96.68% 240 V median; overall power rank #756 (11,567 W, top 32.3%; higher than 67.7% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 48.2 A = 60.2 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11566.9W / 240 V -> 48.2 A | Breaker >= 1.25 * 48.2 = 60.2 A -> 70 A

CEC Inverters.csv for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}: Paco=11566.9 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.56%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 11,567 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 33.276 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.56% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Evaluates Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} (70 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} (70 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 70 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 70 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 70 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 70 A Needs Derate / Tap 705.11
225A Bus / 200A Main 70 A 70 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Sample PV string lengths aligned within 200-480 V MPPT and 480 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Competing CEC grid-support inverters near 11,567 W AC and 240 V, led by Delta Electronics: S12_BDI {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: S12_BDI {240V}
Delta Electronics
11,589 W +22 W 240.0 V 480.0 V 96.99%
Base Power Inc: MIN 11400TL-XH-US {240V}
Base Power Inc
11,520 W -47 W 240.0 V 480.0 V 97.76%
Dyness Digital Energy Technology Co LTD: TX114K-AM {240V}
Dyness Digital Energy Technology Co LTD
11,519 W -48 W 240.0 V 490.0 V 96.21%
Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}
Dyness Digital Energy Technology Co LTD
11,498 W -69 W 240.0 V 500.0 V 96.41%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}?

Check Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} (11,567 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V}.

Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (48.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.56%) and MPPT window (200-480 V) directly against Delta Electronics: S12_BDI {240V} (11,589 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} by Shenzhen Senergy Technology Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} require?

At 11,567 W continuous AC (240 V), continuous current is 48.2 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

Does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.

How does Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} compare to Delta Electronics: S12_BDI {240V}?

Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V} delivers 11,567 W AC at 96.56% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: S12_BDI {240V} outputs 11,589 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.