Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} — CEC Inverter Specifications

Manufacturer: Shenzhen Growatt New Energy Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} outputs 49,218 W AC at 480 V, 3-phase (59.2 A continuous, 80 A OCPD), ranking #1,423 of 2,343 CEC inverters at 96.58% efficiency with a 520-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
49,218 W
AC Voltage
480 V, 3-phase
Min PV Breaker
80 A (4 AWG Cu)
CEC Efficiency
96.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} Compare Against Peer CEC Listings?

Breaker sizing (80 A), 4 AWG Cu wire rules, and DC input limits for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}.

For NEC 705.12 solar interconnection, Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} outputs 59.2 A continuous AC at 480 V, 3-phase and needs an 80 A backfeed breaker on 4 AWG Cu (75 C). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Conversion efficiency scores 96.58% (#1,423 of 2,343, -0.24 pts vs overall CEC median).

Where Does Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} Fall Across Listed CEC Models?

Output power comparison showing where Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} (49,218 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Growatt N: 49,218 W

What Dataset Percentiles Define Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}?

Relative ranking of Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} Technical ThresholdsPercentile comparison for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output49,218 WCEC Efficiency96.58%Backfeed Breaker80 A

What Do the Dataset Ranks Show for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}?

Snapshot of Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} efficiency rank (#1,423), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,423 / 2,343

96.58% CEC Weighted Efficiency

-1.44 pts vs the 98.02% 480 V median; overall power rank #468 (49,218 W, top 20.1%; higher than 79.9% of peers).

NEC 705.12 Check

80 A Required Backfeed OCPD

125% x 59.2 A = 74.0 A -> 80 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

520 V - 800 V (Max 800 V DC)

Tracking span of 280.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 49218.3W / 480 V 3-phase -> 59.2 A | Breaker >= 1.25 * 59.2 = 74.0 A -> 80 A

CEC Inverters.csv for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}: Paco=49218.3 W, Vac=480 V, Vdcmax=800.0 V, Eff=96.58%.

Result: Min 80 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 49,218 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 520 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 77.2117 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.58% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} at 480 V, 3-phase.

Evaluates Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} (80 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 80 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 80 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 80 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 80 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 80 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}?

Minimum and maximum series solar module strings fitting Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} MPPT and 800 V limits.

Sampled CEC PV modules aligned within 520.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 13 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 16 to 18 panels 7.92 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 16 to 17 panels 7.22 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 18 to 19 panels 3.8 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}?

Peer 480 V, 3-phase CEC inverters near 49,218 W AC output such as Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}
Ginlong Technologies Co Ltd
49,800 W +582 W 480.0 V 850.0 V 97.14%
Fortress Power LLC: FP-Nano-50k-N {480V}
Fortress Power LLC
49,803 W +585 W 480.0 V 850.0 V 97.41%
Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US(21A) {480V}
Ginlong Technologies Co Ltd
49,803 W +585 W 480.0 V 850.0 V 97.41%
CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V}
CSI Solar Co Ltd
49,848 W +630 W 480.0 V 850.0 V 98.29%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}?

Check Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} (49,218 W AC, 80 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V}.

Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on an 80 A OCPD breaker (59.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.58%) and MPPT window (520-800 V) directly against Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} (49,800 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} by Shenzhen Growatt New Energy Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} require?

At 49,218 W continuous AC (480 V, 3-phase), continuous current is 59.2 A; 125% NEC 690.8/705.12 sizing requires an 80 A breaker and 4 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} require?

At 49,218 W AC and 480 V, 3-phase, continuous line current is 59.2 A, requiring an 80 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} compare to Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V}?

Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V} delivers 49,218 W AC at 96.58% CEC efficiency with a 800 V DC ceiling, while Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V} outputs 49,800 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.